33
6.4.
Set temperature safety settings
When the temperature in a climate room gets above a certain value, the
planted crops will start to degrade. If this rise in temperature occurs, it is
desirable to dim or shut down the lights in the climate room to reduce the
temperature in the room.
The controller offers the possibility to set a temperature at which it will dim
the lights and a temperature on which it will shut down the lights. Through its
temperature sensors, it can sense when a harmful temperature is reached.
To set the auto-dim temperature, go to paragraph 6.4.1. To set the shut-down
temperature, go to paragraph 6.4.2.
6.4.1.
Setting the auto-dim temperature
Note:
The default auto-dim temperature is set at 30
0
C / 86
0
F.
Note:
The auto-dim temperature cannot be set higher than the shutdown
temperature.
Note:
The auto-dim will decrease the light intensity to 50% over a span of two
degrees Celsius or 3,6 degrees Fahrenheit (20)
Warning!
Always set the auto-dim temperature at least two degrees Celsius /
3,6 degrees Fahrenheit above the temperature of the climate control system.
This will prevent the controller from interfering with the climate control
system.
Output level
100%
50%
Auto dim
temperature
2 degrees Celcius
3,6 degrees Fahrenheit
Shutdown temperature
Temperature
20
Auto-dim and shutdown behavior