GA-02.035-EN-30.05.17
Page 11 of 46
gACC-499E/U Communication unit
gACC-499E_U_Manual_EN.doc
Channel OBIS code
Parameter
Factor
Unit
A1
23.2.0
VN
Volume converted
1
m3
A2
1:12.0.0
SVB
Vol. measured at error
1
m3
A3
13.1.0
VB
Volume measured
1
m3
A4
1:13.0.0
VBZ
Volume Encoder
1
m3
A5
0:41.0.0
T
Gas temperature
10
K
A6
0:42.0.0
PABS
Pressure gas
1000
mbar
A7
97.97.0
ALRACT1
Status information* gAVC1200
1
-
B1
1:13.0.0
VBZ
Volume Encoder
1
m3
B2
13.1.0
VB
Volume measured
1
m3
B3
23.2.0
VN
Volume converted
1
m3
B4
1:12.0.0
SVB
Vol. measured at error
1
m3
B5
0:41.0.0
T
Gas temperature
10
K
B6
0:42.0.0
PABS
Pressure gas
1000
mbar
B7
7-1:0.2.14
FabNo
Serial no. gas meter
1
-
B8
C.91.10
Herst
Manufacturer gas meter
1
-
B9
C.91.11
HerstJahr
Year of built gas meter
1
-
B10
97.97.0
ALRACT1
Status information* gAVC 1200
1
-
B11
1:13.0.0
VBZlastmonth Vb index end of month 06:00 hour 1
m3
B12
23.2.0
VNlastmonth
Vn index end of month 06:00 hour 1
m3
* The status information of the gAVC 1200 concerns the current status information.
The units for temperature and pressure can be adjusted from K and mbar to C and bar.
The IEC62056-21 will be automatically adjusted after changes the units.
Channel OBIS code
Parameter
Factor
Unit
A5
0:41.0.0
T
Gas temperature
1
C
A6
0:42.0.0
PABS
Gas pressure
1
bar
B5
0:41.0.0
T
Gas temperature
1
C
B6
0:42.0.0
PABS
Gas pressure
1
bar
/protocol
End of protocol. The order of the channels is defined in the table above.
uptime
hourstart="18"
minutestart="00" (at 18:00 hours the modem is switched on)
minutesduration="30" (The modem stays switched on for 30 minutes before dial-in)
upaftercallin="5" (After disconnecting the modems stays switched on for 5 minutes)
Note:
The time set at “minutesduration’ can never be exceeded by “upaftercallin”
daylight="Y" (Summertime is enabled, with
“N” it’s disabled
NoIntermediateGSM=”N” The TC65i module is enabled for data communication, with “Y”
only the internal measuring data will be moved to the system memory.
/dual1
End of the first block of the config file.
Содержание gACC-499E/U
Страница 41: ...GA 02 035 EN 30 05 17 Page 41 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...
Страница 42: ...GA 02 035 EN 30 05 17 Page 42 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...
Страница 43: ...GA 02 035 EN 30 05 17 Page 43 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...
Страница 44: ...GA 02 035 EN 30 05 17 Page 44 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...