background image

Instructions for SW400DC

www.gatexpertstore.com

10

4.3.4 Size of Control Box

Control box without built-in battery

Control box

with built-in battery

Figure 9

Warning

To ensure safety, please install the limit stopper at the close limit position

when the door opens inward (as shown in figure 8).

Before installing the main machine, please make sure the main machine and

components are in good mechanical performance and the door can be manually

operated flexibly.

One control unit can optionally drive one main machine or two main machines.

Earth leakage circuit breaker must be installed on where the gate movement can

be seen, and the minimum mounting height for the control box should be over

1.5m to avoid being touched by kids.

After installation, please check whether the mechanical property is good or not,

whether gate movement is flexible or not after unlocking, and whether the

infrared sensor (optional) is installed correctly and effectively.

2 1 0 m m

29

9m

m

1 3 3 m m

8 8 m m

29

9m

m

2 1 0 m m

Содержание SW400DC

Страница 1: ...Swing Gate Opener User Manual SW400DC Website www gatexpertstore com E mail sales gatexpertstore com ...

Страница 2: ...replace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information in the form below All personal information you provided will be only used for warranty service and kept strictly confidential Refer to this list when contacting GATEXPERT for technical service or assistan...

Страница 3: ... Main Machine Installation 7 4 3 4 Size of Control Box 10 5 Wiring and Debugging 11 5 1 Wiring Instructions 11 5 2 Control Board Drawing and Instructions 12 5 3 Digital Screen Setting 13 5 4 Travel Setting 13 5 5 Trimmer Setting 14 5 6 Learning Remote Control Delete Remote Control 14 5 6 1 Learning Remote Control 14 5 6 2 Delete Remote Control 14 5 6 3 Special Remote Control Key button 15 5 7 Cont...

Страница 4: ...is correct Please check if additional equipments or materials are required to meet the specific requirements The disposal of packaging material must be complying with the local regulation Please do not change any parts except for those defined under this manual Any undefined changes may cause the malfunction Any damages to the product arising therefrom shall be beyond the liability of the company ...

Страница 5: ...lease keep this instruction properly for future reference 2 Packing List Standard No Picture Name Quantity 1 Main machine 2 2 Control box 1 3 Manual release bar 1 4 Remote control 2 5 Wall bracket 4 6 Front mounting bracket 2 7 Connecting bracket 2 8 Mounting screw short 2 9 Mounting screw long 2 10 Screw M8 25 4 11 Nut M8 6 12 Limit stopper 1 ...

Страница 6: ...1 2 3 Wireless keypad 1 3 Alarm lamp 1 4 Electric lock 1 5 Storage battery 2 3 Technical Parameters Model SW400DC Power supply 220V 50Hz 110V 60Hz Motor power 62W Gate moving speed 22 26s 90 Max single leaf weight 400kg Max single leaf length 3m Max piston stroke 45cm Max force 3800N Remote control distance 30m Remote control mode Single button mode Storage battery optional DC24V 4 5Ah or 9Ah ...

Страница 7: ...ate weight less than 400kg and the length shorter than 3m The drive mode adopts the worm and worm gear to combine the screw rod transmission This gate opener must be installed inside the enclosure or yard for protection 4 1 Installation Drawing 0 8 5 6 9 7 4 1 2 3 Figure 1 Control box Gate Infrared sensor optional Remote control Gate opener Alarm lamp optional Limit stopper Wireless keypad optiona...

Страница 8: ...ly and the door limit stopper can effectively prevent the door to continue moving Please keep a distance of 40 50mm between the door bottom and the ground for installing the electric lock If electric lock is not required the distance between the door bottom and the ground should be 20mm The recommended mounting height of the 2 main machines is around 300 800mm above the ground and make sure there ...

Страница 9: ...e front mounting bracket and the connecting bracket are in the same level Expansion screw Hexagon screw Nut Nut Hexagon screw Nylon gasket Figure 4 b The connecting bracket and wall bracket can be connected according to different conditions please refer to figure 5 Figure 5 c Users should prepare power cables for the control box and the main machines by themselves due to the different installation...

Страница 10: ...ate the bar until it s released as shown in Figure 6 then turn the telescopic arm you ll find it is stretched easily Left engine Right engine Figure 6 4 3 3 Main Machine Installation Please refer to Figure 7 to fix the tail of the main machine and the connecting bracket with the installation screws and then manually adjust the telescopic arm to the appropriate length finally fix the telescopic arm...

Страница 11: ...limit stopper stopper installed installed It It is is recommended recommended to to install install with with a safety safety stopper stopper should should be be prepared prepared by by the the users users themselves themselves Figure 8 A mm B mm C mm D max L mm SIZE 240 115 15 100 1400 220 125 25 100 1440 200 135 35 100 1420 180 145 45 90 1420 Table 1 Recommended Installation Position ...

Страница 12: ... It is is recommended recommended to to install install with with a safety safety stopper stopper should should be be prepared prepared by by the the users users themselves themselves Figure 9 A mm B mm C mm D max L mm SIZE 170 170 40 90 1000 180 170 30 100 1000 190 170 30 100 1000 200 180 40 100 1000 Table 2 Recommended Installation Position Note Value B must be close or equal to the value A to r...

Страница 13: ...chanical performance and the door can be manually operated flexibly One control unit can optionally drive one main machine or two main machines Earth leakage circuit breaker must be installed on where the gate movement can be seen and the minimum mounting height for the control box should be over 1 5m to avoid being touched by kids After installation please check whether the mechanical property is...

Страница 14: ...Mains input input FUSE FUSE 10A 10A 24V 24V battery battery input input 24V 24V battery battery input input Solar Solar power power input input Solar Solar power power input input Motor2 Motor2 Electric Electric Lock Lock Alarm Alarm Lamp Lamp 24V 24V 12V 12V Motor1 Motor1 Limit Limit signal signal Common Common Motor1 Motor1 Limit Limit power power supply supply Motor2 Motor2 Limit Limit power po...

Страница 15: ... Input 3 BATT 24V Battery Input 4 FORCE Resistance Force 5 SLOW DOWN Slow Stop Distance 6 SPEED Moving Speed 7 MOTOR1 Motor1 Output 8 MOTOR2 Motor2 Output 9 ELOCK Electric Lock Output 10 BLK Alarm Lamp Output Note pay attention to the negative and positive 11 24V 24V Output Positive 12 12V 12V Output Positive No output under dormant state 13 EM1 Motor1 Hall Sensor Power Output 14 LM1 Motor1 Hall S...

Страница 16: ...clutch and then press and hold the button on the control board until the digital screen shows SU After this step the gate will firstly run towards the closing direction and stop and then the gate will automatically open When the two swing gates are fully open the gates will automatically close for the second time and the travel setting will be completed when the gates are closed If the distance of...

Страница 17: ... the opening and closing travel time This adjustment must be finished before travel setting Figure 13 5 6 Learning Remote Control Delete Remote Control 5 6 1 Learning Remote Control Press and hold button the alarm light will keep flashing and digital screen displays remote control mode PO two swing gates single channel mode Pd single gate four channel mode Press the button of the remote control to...

Страница 18: ...s PROG to enter into base menu Digital screen shows NE select other functions of this menu by and buttons Press SET to confirm or to enter into sub menu To exit menu press PROG If no command for one minute the menu will automatically exit Base Menu Automatic closing mode Standard mode Open Close Stop Dual gates mode To switch single gate mode dual gates mode Single gate mode Community mode Open ga...

Страница 19: ...Instructions for SW400DC www gatexpertstore com 16 15 seconds default Automati c closing time Remote control mode Dual gates single channel mode Four channel Single gate single channel Delete remote ...

Страница 20: ...nction will be canceled Community mode with automatic closing function When the gate opens any gate command will not be responded until it closes automatically If user sends gate command during the closing process then the gate will reopen If a gate command is sent during the automatic closing waiting time this waiting time will be recalculated If the gate is not closed completely for more than th...

Страница 21: ... gate time interval is 0 15 seconds default 3 seconds If the interval shorter than 2 seconds then the electric lock cannot be used 3 seconds Automatic Closing Time Automatic closing time can be set as 15 default 30 60 90 seconds 15 seconds Remote Control Mode Dual gates single channel mode Four channel mode Single gate single channel mode Delete all paired remote controls ...

Страница 22: ...ort press SET to confirm or to enter into sub menu Short press PROG to exit If no command for one minute the menu will automatically exit Advanced Menu Photo sensor Photo sensor normally on Initial screen Photo sensor normally off Electric lock normally on Alarm lamp Electric lock Alarm lamp normally on Time of of gate 1 Time of of gate 2 Travel time adjustme nt Electric lock normally off ...

Страница 23: ...20 Alarm lamp normally flash Low consumption mode off Low consumpti on mode Gate opener secection Stop block Hall sensor Default setting Factory default setting Limit switch mode Low consumption mode on Factory default setting SW400DC SW300DC SW200DC ...

Страница 24: ...s more far Photo Sensor N C photo sensor normally is on Default N O photo sensor normally off N O photo sensor normally on Electric Lock Electric lock normally is on Default Electric lock normally is off Electric lock normally on Alarm Lamp Alarm lamp normally is on 24V power supply Default Alarm lamp normally flashes 24V power supply Alarm lamp normally is on 24V power supply Low Consumption Mode...

Страница 25: ...cel factory default setting Factory default setting completes 6 Others 6 1 Maintenance Check whether the gate operates normally every month For the sake of safety each gate is suggested to be equipped with infrared protector and regular inspection is required as well Before installation and operation of the gate opener please read all instructions carefully We reserve the right to change the instr...

Страница 26: ...ell mounting position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not completed 1 Change the remote control battery 2 Re conduct remote control learning Press OPEN CLOSE button the gate is not moving motor has noise Gate moving is not smoothly According to th...

Отзывы: