Instructions for GT1000DCL
www.gatexpertstore.com
Step 9 - Testing Travel and Limit Stops
Testing the Closed Position
·
Ensure gate opener is installed as per step 5, 6 and 7 and the sliding gate is in the middle
position.
·
Press remote (remotes included in kit are factory paired to the motor). The sliding gate will
begin to close.
·
The limit switch stop will hit the limit switch and the sliding gate will stop.
·
When the gate stops, measure the distance remaining between the sliding gate and the desired
closed position.
·
You have now determined the closed position of the sliding gate when the limit switch stop hits
the limit switch.
·
Adjust the limit switch stop from the measurement you have taken to get your final gate closed
position. The ideal closed final position for the gate frame is 10-15mm from closed gate end
catch.
Testing the Open Position
·
Press remote, the sliding gate will begin to open.
·
The limit switch stop will hit the limit switch and the sliding gate will stop.
·
When the gate stops, measure the distance remaining between the sliding gate and the desired
open position.
·
You have now determined the open position of the sliding gate when the limit switch stop hits
the limit switch
·
Adjust the limit switch stops from the measurement you have taken to get your final gate open
position. The ideal open final position for the gate frame is 10-15mm from the gate stop.
To Reset:
When setting new limit stop positions please ensure that you turn the power off and then on
again. Turning the power off will reset the limit stop memory, allowing for new limit switch
stop positions to be recognized by the motor.
Now the basic open and closed positions are set, for further setting functions and adjusting
parameters, please refer to pages 15-25 in this manual.