background image

49

Memory Configuration     

Parameter

Description

Options

System Memory

Total size of system memory detected 
during POST.

Extended 
Memory

Total size of extended memory 
detected during POST.

DIMM Status

The size of memory installed on each 
of the DDR2 Unbufferred DIMM slots.

Memory Retest

Select whether to delete the historical 
memory data log. System memory will 
be retested on the next boot-up.

Yes
No

Содержание GT110 Series

Страница 1: ...GT110 Series User Guide GT110...

Страница 2: ...Model Number Serial Number Purchase Date Place of Purchase 2009 All Rights Reserved Gateway GT110 Series User Guide Gateway GT110...

Страница 3: ...he power cord to the AC power outlet Unplug the power cord before removing the power supply unit from the computer If the system has multiple sources of power disconnect power from the system by unplu...

Страница 4: ...w anything to rest on the power cord Do not locate this product where people will walk on the cord If an extension cord is used with this product make sure that the total ampere rating of the equipmen...

Страница 5: ...roduct was exposed to rain or water The product has been dropped or the case has been damaged The product exhibits a distinct change in performance indicating a need for service The product does not o...

Страница 6: ...n check www lamprecycle org Tips and information for comfortable use Computer users may complain of eyestrain and headaches after prolonged use Users are also at risk of physical injury after long hou...

Страница 7: ...t glasses or contact lenses glare excessive room lighting poorly focused screens very small typefaces and low contrast displays could stress your eyes The following sections provide suggestions on how...

Страница 8: ...id looking at bright light sources such as open windows for extended periods of time Developing good work habits Develop the following work habits to make your computer use more relaxing and productiv...

Страница 9: ...nt or relocate the receiving antenna Increase the separation between the device and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consu...

Страница 10: ...nty Above all it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model nor does it imply that any product is...

Страница 11: ...such problems occur the user should NOT contact the telecom Fault Service 8 This equipment may not provide for the effective hand over of a call to another device connected to the same line 9 Under p...

Страница 12: ...eless LAN and or Bluetooth only General This product complies with the radio frequency and safety standards of any country or region in which it has been approved for wireless use Depending on configu...

Страница 13: ...ripherals 15 Turning on the system 16 Power on problems 17 Configuring the system OS 18 Turning off the system 19 3 System upgrades 21 Installation precautions 22 ESD precautions 22 Pre installation i...

Страница 14: ...ion 61 Boot menu 63 Exit menu 64 5 System troubleshooting 65 Resetting the system 66 Initial system startup problems 67 Initial troubleshooting checklist 67 Hardware diagnostic testing 69 Checking the...

Страница 15: ...1 System tour...

Страница 16: ...ve bay Allows installation of additional storage devices 3 HDD activity indicator Indicates the status of a system hard drive blue 4 LAN status indicator Indicates the system network connection status...

Страница 17: ...et Connect the system power cord here 2 Main power supply module Provides the system s main power supply 3 PS 2 mouse port Connects to a PS 2 mouse 4 PS 2 keyboard port Connects to a PS 2 keyboard 5 S...

Страница 18: ...cts to an internet or intranet network 9 PCI slot covers Protect the vacant expansion slots 10 System fan Regulates the system airflow 11 Parallel port Connects to parallel devices No Component 1 Powe...

Страница 19: ...5 4 HDD carriers 5 Mainboard 6 PCI slot lock 7 System fan No Component...

Страница 20: ...1 System tour 6 System boards Mainboard No Code Description 1 PS 2 ports Connect to PS 2 mouse and keyboard 2 Serial port Connects to serial devices 3 Parallel port Connects to parallel devices...

Страница 21: ...slot 12 24 pin ATX Power connector 13 SATA 1 SATA cable connector 14 SATA 0 SATA cable connector 15 SATA 3 SATA cable connector 16 SATA 2 SATA cable connector 17 SATA 5 SATA cable connector 18 SATA 4...

Страница 22: ...1 System tour 8 26 PCI E 1 PCI E x8 slot 27 CPU_FAN CPU fan cable connector 28 8 pin ATX Power connector 29 SYS_FAN System fan cable connector No Code Description...

Страница 23: ...clear the CMOS data to its default value by shorting the 2 3 pins BIOS recovery You may put the computer into BIOS recovery mode by shorting the 2 3 pins Jumper position Status 1 2 close Normal defau...

Страница 24: ...can aid in problem diagnosis and troubleshooting Front panel LED indicators There are three LED indicators mounted on the front bezel Jumper position Status 1 2 close Enable BIOS recovery 2 3 close No...

Страница 25: ...dicator Color State Representative Status 2 HDD activity Blue Flashing HDD access N A Off No access and no HDD fault 3 Power Blue On S0 Power on Blue Flashing 1 Hz with at 50 duty cycle S1 Sleep N A O...

Страница 26: ...bps connection Off Port identification with 10 Mbps connection Green On 100 Mbps connection Green Flashing Port identification with 100 Mbps connection Yellow On 1 Gbps connection Yellow Flashing Port...

Страница 27: ...2 System setup...

Страница 28: ...ean and dust free Stable surface free from vibration Well ventilated and away from sources of heat Secluded from electromagnetic fields produced by electrical devices such as air conditioners radio an...

Страница 29: ...uctions for each port Note Consult the operating system manual for information on how to configure the network setup Caution Do not route the power cord where it will be walked on or pinched by items...

Страница 30: ...t a series of power on self test POST messages appears The POST messages indicate if the system is running well or not Note If the system does not turn on or boot after pressing the power button go to...

Страница 31: ...outlet and to the power cord socket No power comes from the grounded power outlet Have an electrician check your power outlet Loose or improperly connected internal power cables Check the internal cab...

Страница 32: ...e disc tray slides open insert the Gateway Smart Setup DVD with the label side of the disc facing upward Note When handling the disc hold it by the edges to avoid smudges or fingerprints 4 Press the d...

Страница 33: ...user documentation To turn off the system via software 1 Press Ctrl Alt Delete on the attached keyboard or click Start on the Windows taskbar 2 Select Shut Down 3 Select Shut Down from the drop down m...

Страница 34: ...2 System setup 20...

Страница 35: ...3 System upgrades...

Страница 36: ...side down Wear a wrist grounding strap and attach it to a metal part of the server before handling components If a wrist strap is not available maintain contact with the server throughout any procedu...

Страница 37: ...ions Perform the steps below after installing a server component 1 See to it that all components are installed according to the described step by step instructions 2 Reinstall any expansion board s pe...

Страница 38: ...erver before you can install upgrade components The left side panel is removable to allow access to the server s internal components Refer to the following sections for instructions Removing the side...

Страница 39: ...Perform the pre installation instructions described on page 22 2 Remove the side panel described on page 24 3 Remove an available HDD carrier from the side of the chassis Press tabs together and pull...

Страница 40: ...SAS cables to the new HDD 8 Observe the post installation instructions described on page 23 Installing a 5 25 storage device The two 5 25 device bays support a variety of storage devices for additiona...

Страница 41: ...e installation instructions described on page 22 2 Remove the side panel described on page 24 3 Remove the 5 25 bay cover 1 and EMI protector 2 4 Slide the tool less bracket to the left to unlock the...

Страница 42: ...bles 4 to the new 5 25 drive 7 Observe the post installation instructions described on page 23 To upgrade or replace a defective storage device 1 Perform the pre installation instructions described on...

Страница 43: ...oard supports Intel Xeon 3000 Sequence and Pentium processors Observe the following guidelines when replacing or installing a processor The CPU socket must always be populated If no processor is insta...

Страница 44: ...rewdriver to loosen the four HSF mounting pins 2 Once you have loosened all four mounting pins lift the HSF away from the mainboard 3 Disconnect the heat sink fan cable from the mainboard Use an alcoh...

Страница 45: ...the new processor 1 Hold the processor by its edges then insert it in the socket Make sure that the alignment tabs on the socket fit the two notches located on the edges of the processor The pins are...

Страница 46: ...he processor socket retention plate 2 Apply a thin layer of thermal interface material before installing the HSF Make sure that only a very thin layer is applied so that both contact surfaces are stil...

Страница 47: ...3 3 Reconnect the HSF cable to its mainboard connector Refer to the Mainboard section on page 6 for the location of the HSF connectors 10 Observe the post installation instructions described on page 2...

Страница 48: ...only approved 240 pin DDR2 unbufferred DIMM ECC modules in 1 GB or 2 GB capacities Use identical modules same specification for size speed and organization The minimum memory configuration is one DIMM...

Страница 49: ...erred DIMM make sure to back up all important system files 1 Perform the pre installation instructions described on page 22 2 Lay the server on its side components showing 3 Remove the DIMM 1 Press th...

Страница 50: ...lot 3 If necessary open the holding clips of the selected DIMM slot 4 Remove the new DIMM from its protective packaging handling it by the edges 5 Install the DIMM 1 Align the DIMM so that the notch o...

Страница 51: ...M is not properly inserted 6 Observe the post installation instructions described on page 23 The system automatically detects the amount of memory installed Run the BIOS setup to view the new value fo...

Страница 52: ...th One PCI Express x8 slot x4 bandwidth Two PCI 32 bit 5 V slots To install an expansion card 1 Perform the pre installation instructions described on page 22 2 Remove the side panel described on page...

Страница 53: ...he slot cover and store it for reassembly later Caution Do not discard the slot cover If the expansion card is removed in the future the slot cover must be reinstalled to maintain proper system coolin...

Страница 54: ...bracket securing the card into place Connect the necessary cables to the expansion card as required 6 Observe the post installation instructions described on page 23 When you turn on the system the BI...

Страница 55: ...4 System BIOS...

Страница 56: ...etup message to make changes to the BIOS setup Note If you repeatedly receive Run Setup messages the battery may be bad In this case the system cannot retain configuration values in CMOS Ask a qualifi...

Страница 57: ...ar correspond to the six primary BIOS Setup menus namely Main Advanced Security Server Boot Exit In the descriptive table following each of the menu screenshots settings in boldface are the default an...

Страница 58: ...le Enter key Display a submenu screen Note Availability of submenu screen is indicated by a Esc If you press this key On one of the primary menu screens the Exit menu displays On a submenu screen the...

Страница 59: ...Sets the date following the weekday month day year format BIOS Version Version number of the BIOS Setup Utility BIOS Date Date when the BIOS Setup Utility was created CPU Type CPU Speed CPU Count Tec...

Страница 60: ...stem BIOS 46 Advanced menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu sc...

Страница 61: ...clock the more instructions the CPU can execute per second Processor CPUID Processor ID number Processor L2 Cache Processor second level cache size detected during POST C1 Enhanced Mode Reduce the cor...

Страница 62: ...the latency associated with memory reads Enabled Disabled Adjacent Cache Line Prefetch Feature that reduces cache latency by making the next cache line immediately available if the processor requires...

Страница 63: ...tected during POST Extended Memory Total size of extended memory detected during POST DIMM Status The size of memory installed on each of the DDR2 Unbufferred DIMM slots Memory Retest Select whether t...

Страница 64: ...n LAN PME Allows user to determine the action of the system when LAN PME wake up event occurs Enabled Disabled Wake On Ring Allows user to determine the action of the system when the modem rings Enabl...

Страница 65: ...ameter Description Option CPU Motherboard DDR Temperature Display the current CPU Motherboard and DDR temperature Voltage Monitor Detects the system s voltage status Fan Monitor Display the current CP...

Страница 66: ...on ROM When enabled this setting will initialize the device expansion ROM for the related PCI slot Enabled Disabled Onboard LAN Controller Enables or disables the onboard LAN Controller Enabled Disabl...

Страница 67: ...isables the Serial ATA Enabled Disabled Native Mode Operation Sets the Native Mode Operation Auto Serial ATA SATA RAID Enable Enables or Disables the SATA RAID Enabled Disabled SATA AHCI Enable Enable...

Страница 68: ...ort 3F8 IRQ4 2F8 IRQ3 3E8 IRQ4 2E8 IRQ3 Serial port B Enables or disables the serial port B Enabled Disabled Base I O address Base I O address and IRQ setting for the selected serial port 3F8 IRQ4 2F8...

Страница 69: ...T Error Pause Select whether to pause POST when a boot up error is detected All Errors No Errors All but Keyboard AC LINK Select mode of operation if power loss occurs Power On Stay Off Last State Num...

Страница 70: ...ngs in the Setup Utility User password Entering this password will allow a user to enter the Setup menus but not have the rights to make changes Power on password When the Password on Boot field is en...

Страница 71: ...up down keys to select a password parameter Set Supervisor Password or Set User Password then press Enter 2 Type the original password then press Enter 3 Type a new password then press Enter 4 Retype...

Страница 72: ...arameter Set Supervisor Password or Set User Password then press Enter 2 Enter the current password then press Enter 3 Press Enter twice without entering anything in the new and confirm password field...

Страница 73: ...re versions Press Enter to access the related submenu Console Redirection Displays console redirection related settings Press Enter to access the related submenu System Management The System Managemen...

Страница 74: ...4 System BIOS 60 window are non configurable...

Страница 75: ...le redirection enables users to manage the system from a remote location Onboard COM A Onboard COM B Disabled Baud Rate Select the baud rate for console redirection 300 1200 2400 9600 19 2K 38 4K 57 6...

Страница 76: ...4 System BIOS 62 Continue CR After POST Select whether to enable console redirection after POST On Off Parameter Description Options...

Страница 77: ...drive priority during system boot up BIOS setup will display an error message if the drive specified is not bootable By default the server searches for boot devices in the following order 1 Optical di...

Страница 78: ...cards changes made and close the BIOS setup Load Setup Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are...

Страница 79: ...5 System troubleshooting...

Страница 80: ...ystem using one of the methods below Perform Purpose To do this Soft boot reset To clear the system memory and reload the operating system Press Ctrl Alt Del Cold boot reset To clear the system memory...

Страница 81: ...d secured Did you press the system power button to turn the server on power on indicator should be lit green Are all device drivers properly installed Are hard disks properly formatted and configured...

Страница 82: ...5 System troubleshooting 68 e g two add in boards sharing the same interrupt...

Страница 83: ...rectly connected to the system 5 Turn on the display monitor 6 Set the display brightness and contrast controls to at least two thirds of their maximum range Refer the documentation that came with you...

Страница 84: ...wing Make sure the power supply module is properly installed Make sure the power cord is connected correctly Make sure that the wall outlet has power Test it by plugging in another device Make sure th...

Страница 85: ...ive cannot read a disc Do the following Make sure you are using the correct type of disc Make sure the disc is properly seated in the drive Make sure the disc is unscratched and free of any contaminan...

Страница 86: ...software to see if the problem is with the copy you are using If the other version runs correctly on the system contact your vendor about the defective software No characters appear on the display mon...

Страница 87: ...using the onboard video controller 2 Verify that the add in video controller card is fully seated in its slot 3 Reboot the system for the changes to take effect 4 If there are still no characters on t...

Страница 88: ...5 System troubleshooting 74...

Страница 89: ...Appendix A Server management tools...

Страница 90: ...r and security settings Go to the BIOS setup chapter on page 41 for details Onboard SATA RAID Configuration Utility Use any of these utilities to configure RAID for the system hard drives LSI MegaRAID...

Страница 91: ...all open applications then restart the server 2 During POST press F2 to access the BIOS Setup Utility 3 Select the Advanced SATA Configuration submenu 4 Change the setting of the SATA RAID Enable fiel...

Страница 92: ...sired RAID level and press Enter to select Strip Size 5 Set the size from 4KB to 128KB Then press Enter to set Capacity 6 Set disk capacity and press Enter to create the volume 7 You will be prompted...

Страница 93: ...Appendix B LSI RAID configuration...

Страница 94: ...faults from No to Yes then click on submit 3 Exit the configuration utility and press Ctrl Alt Del to reboot the server Creating a RAID volume 1 Launch the configuration menu 2 Select Configuration Wi...

Страница 95: ...igning a Hot Spare Disk 1 Launch the configuration menu 2 Select a free disk marked as UNCONF GOOD and listed under Physical Drives 3 Select Make Global Dedicated HSP or Make Dedicated HSP and click o...

Страница 96: ...Appendix B LSI RAID configuration 82...

Страница 97: ...55 boot up sequence 63 C CMOS RAM 42 console redirection 61 D DVD ROM drive location 2 troubleshooting 71 E electrostatic discharge see ESD pre cautions 22 expansion card I O interface 38 install 38...

Страница 98: ...side panel remove 24 supervisor password 56 system boards mainboard 6 system fan location 5 system passwords change 57 power on password 56 remove 58 set 57 supervisor password 56 user password 56 sys...

Страница 99: ...85 U USB ports front 2 rear 4 troubleshooting 72 user password 56...

Страница 100: ...86...

Отзывы: