9
GR585 F1 specifications
Power specifications
1400W Power Supply
Operational Input
Voltage Range
(Vrms)
1200W: 100-140 VAC
1400W: 180 – 240 VAC
Frequency
Range (Nominal)
(Hz)
60/50
Nominal Input
Voltage (Vrms)
100
120
208
200
220
230
240
Max. Rated
Output Wattage
1237.3
1237.4
1403.4
1403.4
1403.2
1403.0
1403.7
Nominal Input
Current (A rms)
14.21
11.95
7.92
7.62
7.13
6.83
6.55
Max. Rated Input
Wattage Rating
(Watts)
1416.74
1428.26
1577.66
1578.62
1560.76
1559.90
1561.00
Max. Rated VA
(Volt-Amp)
1421.0
1434.0
1584.0
1585.0
1568.6
1570.9
1572.0
Efficiency (%) at
Max. Rated
Output Wattage
87.33%
86.64%
88.95%
88.90%
89.91%
89.94%
89.92%
Power Factor
0.997
0.996
0.996
0.996
0.995
0.993
0.993
Leakage Current
(mA)
1.1
1.2
1.1
1.1
1.2
1.2
1.2
Max. Inrush
Current (A peak)
16.74
15.98
16.05
16.11
15.70
15.89
16.20
Max. Inrush
Current Duration
(mS)
4.61
4.60
4.63
4.63
4.65
4.72
4.75
Max. British
Thermal Unit
Rating (BTU/hr)
4222.90
4223.24
4789.80
4789.80
4789.12
4788.439
4790.82