address is used on both channels such that an address error on any channel is detectable by bad 
ECC. Lockstep Channel mode is the only RAS mode that supports x8 SDDC. 

 

Channel 3 is no function and can’t be populated in this mode. 

 

Follow the population rules described in independent mode. 

 

Lockstep mode needs the channel 1 & channel 2 with identical DIMM. DIMM slot populations within a 

channel do not have to be identical but the same DIMM slot location across channel 1 and channel 2 
must be the same. DIMM1A and DIMM2A should be the same type, size and manufacturer. DIMM1B 
and DIMM2B memory should be the same type, size and manufacturer. DIMM1C and DIMM2C 
memory should be the same type, size and manufacturer.  

 

Same rule is applied to the CPU2. 

 

3 DIMM per channel configuration is only available for single/dual rank RDIMM. 

 

Please refer to the User Guide for complete population for both single and dual processor 

configurations. 

Sparing mode: 

 

In this mode, if system detects degrading memory and system still not crash, the data in failed channel 

will be copied to spare channel. Failed channel is then isolated and spare channel becomes active. But if 
any uncorrectable error happens before the isolation, it will still cause the system stop normal operation. 

 

Channel 3 is the spare channel. Therefore, the effective size will be reduced by one-third. 

 

Follow the population rules described in independent mode. 

 

Sparing mode need all three channels with identical DIMMs. 1A, 2A and 3A should be the same type, 

size and manufacturer. 1B, 2B and 3B memory should be the same type, size and manufacturer. 1C, 2C 
and 3C memory should be the same type, size and manufacturer. Same rule is applied to CPU2. 

 

Memory sparing mode is only supported by Intel Xeon 5600 series processor. Intel Xeon 5500 series 

processor 

does NOT support the memory sparing mode.

 

 

3 DIMM per channel configuration is only available for single/dual rank RDIMM. 

 

Please refer to the User Guide for complete population for both single and dual processor 

configurations. 

 

Memory Identification 

Generally, there are some memory information printed on the label of DIMM, but different vendor may have 
different format. For example: 

 

4GB 2Rx4 PC3-10600R xx xx xxx 

1. Density 

 

1GB, 2GB, 4GB, 8GB, 16GB 

2. Rank 

 

1R = Single Rank 

 

2R = Dual Rank 

 

4R = Quad Rank 

 

Note: if any quad rank DIMM is used, maximum only 2 DIMM per channel can be supported 

Содержание GR380 F1

Страница 1: ...ivers optimized performance per cost solution in enterprise environment deployments Internal view 1 2 x 720 W 80 PLUS gold level efficient easy swap power supplies 1 1 redundant hot pluggable 2 2 x Intel Xeon X5600 series processors 3 18 x DDR3 ECC registered unbuffered DIMMs 4 3 1 redundant cooling fans 5 7 x PCIe expansion slots 6 1 x 5 25 media expansion bay 7 1 x slimline ODD bay 8 16 x 2 5 ho...

Страница 2: ... port may be used at any given time 3 ID LED button 4 Network hard drive and power status indicators Rear I O 1 PS2 mouse and keyboard ports 2 2 x USB ports 3 4 x Gigabit LAN port RJ 45 4 Video port Note Only one video port may be used at any given time 5 Serial port 6 System ID LED 7 Management port RJ 45 ...

Страница 3: ...t Intel 82576EB Gigabit Ethernet Controller 4 ports total Storage Hard disk form factor 2 5 or 3 5 Type SAS SATA SSD with hot plug capability 3 5 Maximum capacity Up to 12 TB SATA HDD 2 TB 3 5 x 6 HDDs Up to 3 6 TB SAS 600 GB 3 5 x 6 HDDs 2 5 Maximum capacity Up to 16 TB SATA HDD 1 TB 2 5 x 16 HDDs Up to 9 6 TB SAS 600 GB 2 5 x 16 HDDs Storage Controllers Integrated Intel ICH10R Serial ATA host co...

Страница 4: ...ne Power off button LED indicators Power HDD activity LAN port 1 through 4 ID and System status Rear PS2 keyboard port PS2 mouse port Two USB 2 0 ports BMC Management port Serial port Video port 4 x Gigabit port ID LED Optical drive Slim line SATA DVD Super multi 5 25 tape drive Chassis Form Factor 2U rack optimized Power Supply 2 x 720 W 80 PLUS gold level efficient easy swap power supply 1 1 red...

Страница 5: ...udes a single HDD CPU and RAM and PSU 28 5 kg 62 8 lbs System inlet temperature Operating 10 35 C 50 95 F Non operating 40 70 C 40 158 F Relative humidity Operating 8 90 Non operating 5 95 Acoustics Idle LWAd 6 4 BA LpAm 45 8 dBA Operating LWAd 7 2 BA LpAm 53 6 dBA Power Rated Steady state power 720 W Maximum Peak Power 728 W BTU rating 2456 64 BTU hr at 100 240 VAC ...

Страница 6: ...ning to a PCIe connector 2 Default bus assignment in decimal Inserting cards with PCI bridges may alter the actual bus assignment number 3 Slots are enumerated differently based on the operating system Microsoft operating systems enumerate Device ID by bus starting from the lowest bus to the highest Onboard storage specifications Item Description Controller Intel 82801JR ICH10R I O Controller Hub ...

Страница 7: ...NC SI SMBus PXE iSCSI boot Virtualization acceleration Intel I O Acceleration Technology Virtual Machine Device Queues VMDq PCI SIG SR IOV implementation Connector RJ 45 Supported cable type CAT 5e wire Memory specifications and population Item Description Supported memory types Registered DDR3 1066 1333 MHz Unbuffered DDR3 1066 1333 MHz NOTE Gateway does not qualify mixed memory configurations of...

Страница 8: ...least one half Channel 3 is no function and can t be populated in this mode Follow the population rules described in independent mode Mirroring mode needs the channel 1 channel 2 with identical DIMM DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across channel 1 and channel 2 must be the same DIMM1A and DIMM2A should be the same type size and man...

Страница 9: ...annel Failed channel is then isolated and spare channel becomes active But if any uncorrectable error happens before the isolation it will still cause the system stop normal operation Channel 3 is the spare channel Therefore the effective size will be reduced by one third Follow the population rules described in independent mode Sparing mode need all three channels with identical DIMMs 1A 2A and 3...

Страница 10: ...specifications 3 Bit Organization This platform supports x4 and x8 Note It s not recommend to mix DIMM with different bit organization in one system 4 Speed PC3 6400 DDR3 800 PC3 8500 DDR3 1066 PC3 10600 DDR3 1333 ...

Страница 11: ...ge Rating Watts 846 0 836 4 790 4 774 0 822 8 805 0 789 6 Max Rated VA Volt Amp 837 54 828 03 774 59 758 52 806 34 788 9 773 81 Efficiency at Max Rated Output Wattage 88 12 89 49 90 95 90 74 91 51 91 92 92 27 Power Factor 0 99 0 99 0 98 0 98 0 98 0 98 0 98 Leakage Current mA 0 17 0 19 0 29 0 31 0 35 0 37 0 41 Max Inrush Current A peak 17 24 19 41 18 52 16 88 16 48 20 47 22 54 Max Inrush Current Du...

Страница 12: ...ngs to a bootable USB device to ease mass server deployments Smart Console Web based management utility to simplify system management with embedded iBMC system monitoring and alerting event handling remote power control and KVM over IP Smart Console is OS independent and offers virtual media through floppy ODD and removable disk Smart Server Manager v1 1 Offering 24 7 monitoring for system health ...

Страница 13: ...Hz 95 W X5550 8 MB L3 cache 2 66 GHz DDR3 1333 MHz 95 W E5640 12 MB L3 cache 2 66 GHz DDR3 1066 MHz 80 W E5630 12 MB L3 cache 2 53 GHz DDR3 1066 MHz 80 W E5620 12 MB L3 cache 2 40 GHz DDR3 1066 MHz 80 W L5630 12 MB L3 cache 2 13 GHz DDR3 1066 MHz 40 W L5609 12 MB L3 cache 1 86 GHz DDR3 1066 MHz 40 W E5607 8 MB L3 cache 2 26 GHz DDR3 1066 MHz 80 W E5606 8 MB L3 cache 2 13 GHz DDR3 1066 MHz 80 W E56...

Страница 14: ...B 7 2K 300 GB 10K 500 GB 7 2K 1 TB 7 2K Enterprise SATA 2 5 6 Gb s 250 GB 7 2K 500 GB 7 2K 1 TB 7 2K Enterprise SATA 3 5 3 Gb s 250 GB 7 2K 500 GB 7 2K 750 GB 7 2K 1 TB 7 2K 2 TB 7 2K Enterprise SAS 2 5 NOTE SAS drives require an add on RAID card 6 Gb s 73 GB 15K 146 GB 15K 300 GB 10K 450 GB 10K 600 GB 10K Enterprise SAS 3 5 NOTE SAS drives require an add on RAID card 6 Gb s 146 GB 15K 300 GB 15K ...

Страница 15: ...ber Bandwidth Intel Gigabit CT2 desktop adapter 1 10 100 1000 Mbps Supermicro AOC SG i2 server adapter 4 10 100 1000 Mbps Supermicro AOC SG i4 server adapter 4 10 100 1000 Mbps Supermicro AOC STGN i2S server adapter DA2 2 10 Gbps Intel X520 SR1 server adapter 1 10 Gbps Intel X520 SR2 server adapter 2 10 Gbps Intel X520 LR1 server adapter 1 10 Gbps Note Intel s 10GbE cards vary in terms or their co...

Страница 16: ...rm factor LTO Ultrium 3 3Gb s SAS 400 800 GB External 1U rack LTO 4 3Gb s SAS 400 800 GB External 1U rack DAT72 SATA USB TBU 36 GB 72 GB Internal 5 25 half height DAT160 USB TBU 160 GB Internal 5 25 half height TPM module TPM module with STMicro chip ...

Страница 17: ...mation in this document is subject to change without notice Images shown are only representations of some of the configurations available for this model Availability may vary depending on region 2010 All rights reserved Microsoft and Windows are registered trademarks of Microsoft Corporation Intel the Intel logo Xeon and Xeon Inside are trademarks of Intel Corporation NOTE Extension warranty servi...

Отзывы: