Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that
have nothing to do with a hardware defect, such as cosmic radiation,
electrostatic discharge, or software errors. FRU replacement should be
considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1
Run the advanced diagnostic test for the system board in loop mode at
least 10 times.
•
If any error is detected, replace the FRU.
•
If no error is detected, do not replace any FRU.
2
Rerun the test to verify that there are no more errors.
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed,
which installed devices are incorrect, whether a short circuit is suspected, or
whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate a
non-defective FRU).
To isolate a failing FRU:
1
Power-off the computer.
2
Visually check them for damage. If any problems are found, replace the
FRU.
3
Remove or disconnect all of the following devices:
•
Non-Gateway devices
•
Printer, mouse, and other external devices
•
Battery pack
•
Hard disk drive(s)
•
DIMM
•
CD-ROM/Diskette drive Module
•
PC Cards
4
Power-on the computer.
5
Determine if the problem has changed.
Important
Verify that all attached devices are supported by the computer.
Important
Verify that the power supply being used at the time of the failure is
operating correctly. (See
“Power System Check” on page xxvi.
)
Содержание EC54
Страница 1: ... Gateway EC54 EC58 SERVICEGUIDE ...
Страница 15: ...www gateway com 13 System Block Diagram ...
Страница 38: ...CHAPTER 1 System Specifications 36 ...
Страница 42: ...Contents iv ...
Страница 49: ...www gateway com xi 10 Remove all of the screws on the back of the notebook 11 Remove screws on the upper case ...
Страница 60: ...CHAPTER 3 Replacing Notebook Components xxii ...
Страница 81: ...CHAPTER6 xliii FRU Field Replaceable Unit List Introduction Exploded Diagram Gateway EC58 FRU List ...
Страница 83: ...www gateway com xlv Exploded Diagram ...
Страница 84: ...CHAPTER 6 FRU Field Replaceable Unit List xlvi ...
Страница 85: ...www gateway com xlvii ...
Страница 86: ...CHAPTER 6 FRU Field Replaceable Unit List xlvii ...
Страница 87: ...www gateway com xlix ...
Страница 101: ...CHAPTER5 lxiii Connector Locations Top View Bottom View ...
Страница 104: ...CHAPTER 5 Connector Locations lxvi ...
Страница 105: ...APPENDIXA lxvii Model Definition and Configuration ...
Страница 107: ...APPENDIXC lxix Online Support Information ...
Страница 110: ...Index lxxii ...
Страница 111: ...APPENDIXB lxxiii Test Compatible Components Introduction Microsoft Windows Vista Environment Test ...
Страница 115: ......
Страница 116: ...MAN GATEWAY SVC GDE R1 09 ...
Страница 117: ...CHAPTER2 lxxix System Utilities BIOS Setup Utility BIOS Flash Utility ...
Страница 130: ...CHAPTER 2 System Utilities xcii ...