Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that
have nothing to do with a hardware defect, such as cosmic radiation,
electrostatic discharge, or software errors. FRU replacement should be
considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1
Run the advanced diagnostic test for the system board in loop mode at
least 10 times.
•
If any error is detected, replace the FRU.
•
If no error is detected, do not replace any FRU.
2
Rerun the test to verify that there are no more errors.
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed,
which installed devices are incorrect, whether a short circuit is suspected, or
whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate a
non-defective FRU).
To isolate a failing FRU:
1
Power-off the computer.
2
Visually check them for damage. If any problems are found, replace the
FRU.
3
Remove or disconnect all of the following devices:
•
Non-Gateway devices
•
Printer, mouse, and other external devices
•
Battery pack
•
Hard disk drive(s)
•
DIMM
•
CD-ROM/Diskette drive Module
•
PC Cards
4
Power-on the computer.
5
Determine if the problem has changed.
Important
Verify that all attached devices are supported by the computer.
Important
Verify that the power supply being used at the time of the failure is
operating correctly. (
See “Power System Check” on page 60.
)
Содержание EC38
Страница 1: ... Gateway EC38 SERVICEGUIDE ...
Страница 6: ...Contents iv ...
Страница 14: ...CHAPTER 1 System Specifications 8 System Block Diagram ...
Страница 30: ...CHAPTER 1 System Specifications 24 ...
Страница 31: ...CHAPTER2 25 System Utilities BIOS Setup Utility BIOS Flash Utility ...
Страница 41: ...www gateway com 35 ...
Страница 51: ...www gateway com 45 10 Remove screws on the upper case 11 Remove the dummy card ...
Страница 62: ...CHAPTER 3 Machine Disassembly and Replacement 56 ...
Страница 83: ...CHAPTER5 77 Jumper and Connector Locations Top View Bottom View ...
Страница 86: ...CHAPTER 5 Jumper and Connector Locations 80 ...
Страница 87: ...CHAPTER6 81 FRU Field Replaceable Unit List Introduction Exploded Diagram Gateway EC38 FRU List ...
Страница 89: ...www gateway com 83 Exploded Diagram ...
Страница 90: ...CHAPTER 6 FRU Field Replaceable Unit List 84 ...
Страница 91: ...www gateway com 85 ...
Страница 92: ...CHAPTER 6 FRU Field Replaceable Unit List 86 ...
Страница 93: ...www gateway com 87 ...
Страница 107: ...APPENDIXA 101 Model definition and configuration Information not available at time of printing ...
Страница 109: ...APPENDIXB 103 Test compatible components Introduction Microsoft Windows Vista Environment Test ...
Страница 113: ...APPENDIXC 107 Online support information ...
Страница 116: ...Index 110 ...
Страница 117: ......
Страница 118: ...MAN GODZILLA SVC GDE R1 07 08 ...