Chapter 2: Installing and Setting Up your Autoloader
www.gateway.com
24
11
Browse to the location where you saved the drivers on the host computer,
then click
OK
.
12
Click the
SuperLoader 3
entry, then click
Next
.
13
Click
Next
again to install the driver.
14
Click
Finish
.
15
Close the
Device Properties
dialog box.
The autoloader now appears in Device Manager under
Medium Changers
and is ready to use.
Setup
When you first power on the autoloader, it automatically runs a POST (Power-on
Self Test). During the POST, the left (green) LED flashes. After the POST, the left
(green) and right (amber) LED flash alternately back and forth. Do one of the
following:
■
If the autoloader powers on successfully, continue configuring the
autoloader (see
“Configuring the autoloader” on page 24
Important
The front panel requires a six-digit
password to change the configuration
(see “Setting passwords” on page 33). The
LCD front panel default password for the
Administrator is
000000
. The default
password for the Operator is
111111
.
■
If the autoloader does not power on successfully, make sure that:
■
The power switch is on.
■
The power cable is inserted correctly.
■
The SCSI bus is terminated.
■
The SCSI cable is connected to the autoloader and host computer.
■
No error code appears on the autoloader LCD.
■
If you cannot resolve the problem yourself, contact Gateway Customer
Care (see
).
When you first power on the autoloader, the setting for the Internet Protocol
(IP) address is static with the address
192.168.20.128
. If you want to use
Dynamic Host Configuration Protocol (DHCP) to change the IP address, see
“Setting the IP address” on page 26
. To determine the IP address when using
DHCP, view the Ethernet status information (see
Configuring the autoloader
To configure the autoloader, start with the
Main
menu on the front panel. If the
Main
menu is not already visible on the LCD, press
E
NTER
.
When you first power on the autoloader, the default is set with no password
protection. However, after you set the security option, all the configuration
functionality is password-protected. You need an administrator-level password
to configure the autoloader (see
“Default username and password” on page 55
for On-board Remote Management or
“Setting security options” on page 59
for
the front panel).
Содержание E-824R
Страница 1: ...USER GUIDE Gateway E 824R E 826R SuperLoader 3 ...
Страница 5: ...Contents www gateway com iv ...
Страница 6: ...CHAPTER 1 1 Introduction Introduction Features Enclosure components Getting Help ...
Страница 13: ...CHAPTER 1 Introduction www gateway com 8 ...
Страница 14: ...CHAPTER 2 9 InstallingandSettingUpyourAutoloader Overview Preparation Installation Setup ...
Страница 57: ...CHAPTER 3 Operating your Autoloader www gateway com 52 ...
Страница 91: ...CHAPTER 5 Troubleshooting your Autoloader www gateway com 86 ...
Страница 92: ...Appendix A 87 Logs Basic information logs Log descriptions Error codes Tape drive logs POST failure logs ...
Страница 116: ...A MAN E 824R E 826R USR GDE R1 7 06 ...