Documentation Update...
Replacing the Power Supply
This update replaces the procedure provided in the Gateway
8450R System Manual.
The redundant 350-W power supply provides all system
power. If one of the components of the power distribution
hardware fails, you must replace the entire power supply.
1
Turn off the server and disconnect the power cord and
all peripherals.
2
Remove the bezel and both top panels following the
instructions in the system manual.
3
Remove the four screws that secure the upper drive bay
bracket in place, then slide the bracket forward before
lifting it from the chassis.
4
Disconnect the cables from the bottom front side of the
hot-plug fan tray. Note the location and orientation of
each cable so you can connect them correctly to the new
board.
Upper drive
bay bracket
8506762.fm Page 1 Thursday, August 10, 2000 1:32 PM