Replacing the Power Supply

This update replaces the procedure provided in the Gateway 
8450R System Manual
.

The redundant 350-W power supply provides all system 
power. If one of the components of the power distribution 
hardware fails, you must replace the entire power supply.

1

Turn off the server and disconnect the power cord and 
all peripherals.

2

Remove the bezel and both top panels following the 
instructions in the system manual.

3

Remove the four screws that secure the upper drive bay 
bracket in place, then slide the bracket forward before 
lifting it from the chassis.

4

Disconnect the cables from the bottom front side of the 
hot-plug fan tray. Note the location and orientation of 
each cable so you can connect them correctly to the new 
board.

Upper drive 
bay bracket