ISSUED: 04-21-03 SHEET #: 055-9158-1
3 of 8
Visit the Peerless Web Site at www.peerlessindustries.com
For customer service call 1-800-729-0307 or 708-865-8870.
F
F
G
WOOD
JOIST
CEILING
Drill two
5
/
32
" (4 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach ceiling plate (G)
with two #14 x 2.5" (6 mm x 65 mm) wood
screws (F) as shown using
3
/
8
" (10 mm) socket
wrench. Tighten wood screws (F) so ceiling
plate (G) is firmly attached.
DO NOT TIGHTEN WITH EXCESSIVE FORCE!
Overtightening can cause stress damage to
wood screws (F) greatly reducing their holding
power! Tighten to 80 in • lb (9 N.M.) maximum
torque.
WARNING: It is the responsibility of the
installer to verify that the ceiling will safely
support the combined load of all attached
hardware and components.
IMPORTANT: Be sure to drill holes into the
joist CENTER!
For optional Cord Management,
install two spacers (H) between ceiling
plate (G) and ceiling.
Installation To Wood Joist Finished Ceilings,