6. To set auto close time:
When digital display indicates P9, the gate opener is on auto close time setting. There is 0-99s for
optional. 0s mean the gate opener would not auto close. Max auto close time is 99s. Each time
you press and release the [INC+] button, the figure increase by 1; each time you press and release
the [DEC-] button, the figure decreases by 1. Press the [FUN] button to store the data when the
auto close time chosen, then the auto close time setting finished. (factory set 0)
7. To set lamp/alarm output control:
When digital display indicates PA, the gate opener is on lamp/alarm output control setting. There
is 0-3 for optional.
“0” means the alarm on monostabillity model and the lamp without voltage
output after the gate total close 30s, other time with voltage output. “1” means the alarm on
monostabillity model and the lamp would only flash when gate running. “2” means the alarm on
bistabillity model and the lamp without voltage output after the gate total close 30s, other time
with voltage output. “3” means the alarm on bistabillity model and the lamp would only flash when
gate running. Each time you press and release the [INC+] button, the figure increase by 1; each
time you press and release the [DEC-] button, the figure decreases by 1. Press the [FUN] button to
store the data when the auto close time chosen, then the lamp/alarm output control setting
finished. (factory set 0)
8. To set lock time:
When digital display indicates Pb, the gate opener is on lock time control setting. The lock control
time means the time we could control the lock. There is 0-1 for optional. “0” means the lock control
time is 0.5s, “1” means the lock control time is 5s. Each time you press and release the [INC+]
button, the figure increase by 1; each time you press and release the [DEC-] button, the figure
decreases by 1. Press the [FUN] button to store the data when the lock control time chosen, then
the lock time setting finished. (factory set 0)
9. To choose single/double gate open:
When digital display indicates PC, the gate opener is on single/double gate open setting. There is
0-3 for optional. “0” means the gate could not open by remote, “1” means just can open one single
gate, “2” means can just open two leaf gate, “3” means can open one single gate as well as two
leaf gates. Each time you press and release the [INC+] button, the figure increase by 1; each time
you press and release the [DEC-] button, the figure decreases by 1. Press the [FUN] button to store
the data when the single/double gate open chosen, then the remote button setting finished.
(factory set 3)
To choose photocell work in NC or NO
When digital display indicates Pd, you could choose the photocell work in NO or NC.
Value 00 means work in NO, value 01 means work in NC.
11. To reset:
When digital display indicates Po, the gate opener is on rest setting. After enter Po setting, press
the [ FUN] to store and then now the reset successfully.