background image

02. Installation

Fig 1. Standard AEG wiring scheme

BATTERY

UP TO 12.8V

AEG Motor

A

B

CONTACTS

C

To adapt the standard AEG installation to work with 

X-ASR

 it is necessary to get to 

the trigger contacts. In case of GB v2 contacts are located inside a gearbox. With a 

version 3 gearbox, the installation will be easier because the contacts are outside of 

the  gearbox.  Please  consult  a  local  airsoft  technician  if  you  have  never 

disassembled a gearbox before or if you have any installation concerns.

a)  Installation  of  X-ASR  without  replacement  of  wires.

  Using  this  method,  the 

original  wiring  is  kept  intact,  and  the  connections  are  modified.  Referencing

Fig 1., de-solder A wire from the one of the trigger contacts and then solder it to the 

B wire. It does not matter which wire you disconnect from the trigger switches, just 

join the two wires together at one terminal. In the place of the A wire, solder the 

additional single signal wire. The trigger wire can be very thin because it handles 

very low current and it is only used for switch-detection. 

USER GUIDE

1.

AEG Motor

CONTACTS

BATTERY

UP TO 12.8V

07

WWW.GATEE.EU

Содержание X-ASR

Страница 1: ...Last update on MARCH 19 2019 www gatee eu USER GUIDE...

Страница 2: ...DANGER FOR YOUR SAFETY USER GUIDE 02 WWW GATEE EU GATE Enterprise Sp z o o Sp K does not take any responsibility for damages injuries and accidents resulting in the use of this product or the use of A...

Страница 3: ...heremeansthattheproductisclassedasElectricalorElectronicEquipment and should not be disposed with other household and commercial waste at the end of its working life The Waste of Electrical and Electr...

Страница 4: ...03 Troubleshooting Safety Summary Table of Contents 01 Overview Key Functions 04 GATE Limited Warranty Policy Installation of X ASR without replacement of wires AEG standard installation diagram 02 In...

Страница 5: ...Inthatcase youneedaMOSFET It targets the energy from the battery directly to the motor bypassing the mechanical trigger contacts As a result you gain a higher rate of fire of the rifle and faster trig...

Страница 6: ...ilitarySpecificationMIL V 173C Trigger wire TERMINAL AEG Connectors Battery connector LED indicators Motor POSITIVE TERMINAL Motor NEGATIVE TERMINAL Scheme 3 pcs of 3 2x18mm 0 126x0 71 inch heat shrin...

Страница 7: ...r if you have any installation concerns a Installation of X ASR without replacement of wires Using this method the original wiring is kept intact and the connections are modified Referencing Fig 1 de...

Страница 8: ...USER GUIDE 03 built in self test 08 WWW GATEE EU Overload temperature too high X ASR is designed up to M120 spring...

Страница 9: ...uct that has the serial number removed or made illegible c defects or damage from improper operation maintenance or installation d installation of the products GATE Enterprise Sp z o o Sp K warrants t...