60
2.
The battery is worn out and has too high internal resistance
3.
Inadequate battery type for given AEG configuration
4.
Too much electrical resistance between TITAN and the battery
5. Motor too strong for the connected battery
6. Motor connections’ short circuit
7. Motor is jammed
8. Motor is damaged
What to do:
1. Charge the battery
2. Replace the battery
3. Use a battery with more capacity or more voltage
4.
Do not use any adapters
5.
Use standard or high-torque motors instead of high-speed
6. Check and fix the motor wires insulation
7.
Unjam the motor
8. Replace the motor