background image

 

 
 
 

8

 

GateOpen - User manual Rev. 3 – 20/07/10

 

4.1.3 GPRS connection (over the internet) 

 
In order to use this option the GateOpen SIM must support GPRS connection and to have 

fix 

internet IP

, contact the GSM carrier to enable these options. 

Before a GPRS connection can be establish with the unit, the GPRS parameters must be set 
to the unit using direct serial connection, refer to miscellanies screen for more information. 

 
 
 
 
 
 
 
 
 
 

 

 

Open the GTO software and click the “communication selection” button 
 

 

 

Select “IP connection” option, insert the unit password (default password is 1234), insert the 
GateOpen internet IP address and press OK. 
Click the “connect” button to establish the connection to the unit; it can take up to one minute 
to establish the communication. 
When the communication will be established, the disconnect button will appear. 
While connected to the unit, the green LED will turn off and no incoming calls for access 
control will be accepted. 

 
4.1.4 Change the software language 

Click the “Select Language” button, select the wanted language and press OK. 
In order the change to take place, the software must be reopened. 

 

 

Internet

 

Содержание EZgate

Страница 1: ...1 GateOpen User manual Rev 3 20 07 10 EZgate User manual Rev 3 20 07 10...

Страница 2: ...ores white list of authorized users when someone calls the unit the unit hangs up the call and check if the caller ID exists in the list if it does a pulse generated by internal relay command the gate...

Страница 3: ...manual Rev 3 20 07 10 2 General Product Description 2 1 Dimensions 2 2 Weight 120 grams 2 3 Input voltage 5V 30V DC 2 4 Casing material The case made from plastic PC IP54 Avoid exposing the unit to li...

Страница 4: ...pecification 40 C to 85 C The module is fully functional in all the temperature range Temperatures outside the range 20 C to 55 C might slightly deviate from ETSI specifications Storage and Non Operat...

Страница 5: ...sal An internal fuse ensures an electrical safety according to EN60950 This fuse is not removable 3 5 2 Supply voltage requirements A DC power supply must be connected to the Power input Input voltage...

Страница 6: ...commands 4 1 GTO software Main screen buttons 4 1 2 Data call connection CSD connection In order to use this option a GSM modem terminal must be used Verify with the GSM carrier that both SIM cards GS...

Страница 7: ...elect the proper com port insert the GateOpen phone number and press OK Click the connect button to establish the connection to the unit it can take up to one minute to establish the communication Whe...

Страница 8: ...cation selection button Select IP connection option insert the unit password default password is 1234 insert the GateOpen internet IP address and press OK Click the connect button to establish the con...

Страница 9: ...ompare button 2 Wait few seconds 3 The GTO compares batches of 100 users with the GateOpen unit 1 100 101 200 etc If one or more user s in the batch are different all the 100 batch users icons will be...

Страница 10: ...from the list click the Write modified numbers button 2 Wait for the progress bar to fill it can take several minutes depends on the number of records marked as 3 All the written records icons will be...

Страница 11: ...screen section All the descriptions below are enabled only after connecting to the unit Get the restricted users list from the GateOpen unit 1 Click the Retrieve numbers button 2 Verification screen w...

Страница 12: ...nutes 3 All the written records icons will be changed to Write the modified restricted users list to the GateOpen unit In this option only records that marked with icon will be written to the unit 1 A...

Страница 13: ...nt time to the unit retrieve the PC time and then write it to the unit The unit clock will be lost when the power turned off Unit password Define new password for the unit The password is used in the...

Страница 14: ...s the SMS notify option in its record Checking the Send SMS on disapproved users If a disapproved user not in the normal restricted lists or restricted user that is not allowed at the moment calls to...

Страница 15: ...4 1 8 Log Manage the unit log Retrieve the entire log Retrieve the entire log from the unit Most recent long entries Retrieve the last desire amount of entries from the log Delete log Delete all the u...

Отзывы: