10
TROUBLESHOOTING
PROBLEM
CAUSE
REMEDY
The dishwasher does not
operate properly
Connection interruption
Check the connection
You have not turned the
switch of the appliance ON
Turn the switch ON
Main switch / or fuse has not
been activated / or it is faulty
Check the main switch / or
fuse
The switch of the appliance
is faulty
Refer to the authorized local
dealer who sold the
appliance or directly to the
manufacturer
The water inlet valve is faulty
The door is not closed
Close the door
You have not turned the
water supply on
Turn the supply on
The appliance operates, but
the switch LED does not light
on
The LED is faulty
Change the LED
Boiler heating does not
operate
Switch or main switch or
fuse has not been activated
Check the switch of the
appliance and the main
switch or fuse
The safety thermostat of the
boiler is faulty
Refer to the authorized local
dealer or the manufacturer
The 93
℃
thermal fuse of the
boiler is faulty
Pressure regulator is faulty
Refer to the authorized local
dealer or the manufacturer
“Boiler heating” relay is
faulty
Boiler fuse is burned out
Refer to the authorized local
dealer or the manufacturer
Boiler heating operates, but
LED does not turn on
Faulty LED
Change LED
Dispenser heating does not
operate
Switch N1 of the appliance
or main switch or fuse has
not been activated
Activate the corresponding
switch or fuse
Boiler heating is open
Wait
The 85
℃
thermal fuse is
faulty. The dispenser’s fuse is
burned out
The thermostat switch of
60
℃
heating is faulty
Refer to the authorized local
dealer or the manufacturer
“Compartment heating”
relay is faulty
Dispenser’s heating
operates, but LED does not
turn on
Faulty LED
Change LED
Pump motor does not
operate
Main switch or fuse is not
activated. The door is not
closed.
Activate the main switch or
fuse
Close the door
Main relay is faulty
Refer to the authorized local
dealer or the manufacturer
Pump motor is faulty
Program selection switch is
faulty