PRESSURE SWITCH

Installation Use wrench to install .(Do not twist housing to 

install .)

Connecting

Please follow the above wiring method to correct 

the wiring . please check the connection before 

the power .

Set

Zero 

clearing

After power, without pressure, close 

the ‘run’ key, long press ‘

q

’ key for 5 

seconds to zero clearing .

Units 

change

Close ‘run’ key, short press ‘

p

’ key to 

change pressure unit circularly

Upper and 

lower limit 

setting

Close ‘run’ key, short press ‘set’ 

key, it shows lower limit pressure 

and the low pressure warning light 

comes on; press ‘

p

’’

q

’ to change 

the figure(long press, the figure 

changes quickly), after setting, short 

press ‘set’ key to save setting . Then it 

shows upper limit and high pressure 

warning light comes on, press ‘

p

’’

q

’ 

to change the figure(long press, the 

figure changes quickly), after setting, 

short press ‘set’ key to save setting 

and quit automatically . (if the lower 

limit can not reach to the figure you 

want, you can set upper limit firstly .)

Run

After setting, short press ‘run’ key to 

open . (The ‘run’ key must be closed 

before setting)

MAINTENANCE

WARNING

Electrical Shock Hazard

Disconnect electrical power supply before performing

maintenance on this product.
If product is hard-wired into system, disconnect electrical

power at the circuit breaker or fuse box before 

performing maintenance on this product.
Failure to follow these instructions can result in death, fire, 

or electrical shock.

 

WARNING

Injury Hazard

Product surfaces become very hot during operation,

allow product surfaces to cool before handling.
Air stream from the product may contain solid or liquid

material that can result in eye or skin damage, wear proper

eye protection.
Clean this product in a well-ventilated area.
Failure to follow these instructions can result in burns,

eye injury, or other serious injury.

It is your responsibility to: 
•   Regularly inspect and make necessary repairs to product 

in order to maintain proper operation. 

•   Make sure that pressure is released from product before 

starting maintenance.

Check intake and exhaust filters after six months of operation . 
Clean filters and determine how frequently filters should be 
checked during future operation . This one procedure will help to 
assure the product’s performance and service life .
1 .  Remove filter cover .
2 .  Check filter felt . Replace felt if it is covered with 

contamination or shows signs of increasing differential 
pressure .

3 .  Reinstall felt and filter cover .

Содержание 87R

Страница 1: ...t Manufacturing Inc Copyright 2020 Gast Manufacturing Inc All Rights Reserved www gastmfg com ISO 9001 CERTIFIED A UNIT OF IDEX CORPORATION Part No 70 6856 Rev A Operation and Maintenance Manual 87R Riser Mount Dry Pipe Sprinkler Compressor ...

Страница 2: ... and safety instructions and you will receive years of trouble free service TABLE OF CONTENTS Product Use and Safety 3 Installation 3 Mounting Plumbing 3 and 4 Motor Control 4 Operation 4 Pressure Switch 5 Maintenance 5 Accessories Intake Filter 6 Technical Data Part Numbering 7 Exploded View 8 Pneumatic Schematic 9 Electrical Schematic 10 Troubleshooting Chart 11 Warranty 12 WARNING PLEASE READ T...

Страница 3: ...happen if the safety instructions are not followed INSTALLATION WARNING Electrical Shock Hazard Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other liquids Install this product where it will be weather protected Electrically ground this product Failure to follow these instructions...

Страница 4: ...Check that power source is correct to properly operate the motor WARNING Electrical Shock Hazard This product must be properly grounded Check the condition of the power supply wiring Do not permanently connect this product to wiring that is not in good condition or is inadequate for the requirements of this product Failure to follow these instructions can result in death fire or electrical shock M...

Страница 5: ...closed before setting MAINTENANCE WARNING Electrical Shock Hazard Disconnect electrical power supply before performing maintenance on this product If product is hard wired into system disconnect electrical power at the circuit breaker or fuse box before performing maintenance on this product Failure to follow these instructions can result in death fire or electrical shock WARNING Injury Hazard Pro...

Страница 6: ...ovements Printed in the USA 6 Part No 70 6856 Rev A ACCESSORIES INTAKE FILTER The product s external intake will provide adequate filtration in most applications Check filters periodically and replace when necessary Consult your Gast Distributor Representative for additional filter recommendations Item B300A ...

Страница 7: ...n 30 min gallons 296 Current amps 5 7 Weight lbs 42 Noise Level dB A 63 Dimensions LxWxH in 13 8 x 9 9 x 20 2 Motor HP 1 2 Max Pressure psi 55 Tank Size liters 2 Thermal Protection Yes Duty Cycle 100 Relative Humidity 20 80 Ambient Temperature 4 40 C NDERSTANDING YOUR PART NUMBER S X 0 0 1 Voltage 1 120 2 230 Alpha Numerical Engineering Code 87R Compressor Series WiFi 0 No 1 Yes Riser Mount Alpha ...

Страница 8: ...anufacturing We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA 8 Part No 70 6856 Rev A EXPLODED PRODUCT VIEW PARTS AND ORDERING INFORMATION SINGLE B300A ...

Страница 9: ... 2020 Gast Manufacturing We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA 9 Part No 70 6856 Rev A PNEUMATIC SCHEMATIC ...

Страница 10: ... 2020 Gast Manufacturing We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA 10 Part No 70 6856 Rev A ELECTRICAL SCHEMATIC ...

Страница 11: ...ter E Remove filter and clean or replace as necessary F Start up unloader is not functioning F Verify the unloader is purging on start up If not replace start up unloader G Unit is overheated G Verify voltage Relocate system installation H Check valve leaking H Clean or replace the check valve I Loose wiring I Verify all wiring is tight J Switch NOT in RUN mode J Put the pressure switch into RUN m...

Страница 12: ...or otherwise Notwithstanding any other provision of this warran ty BUYER S REMEDY AGAINST GAST FOR GOODS SUPPLIED OR FOR NON DELIVERED GOODS OR FAILURE TO FURNISH GOODS WHETHER OR NOT BASED ON NEGLIGENCE STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY IS LIMITED SOLELY AT GAST S OPTION TO REPLACE MENT OF OR CURE OF SUCH NONCONFORMING OR NON DELIVERED GOODS OR RETURN OF THE PURCHASE PRICE...

Отзывы: