Extension Cords
Use only a 3-wire extension cord that has a 3-blade grounding
plug . Connect extension cord plug to a matching 3-slot
receptacle . Do not use an adapter . Make sure your extension cord
is in good condition . Check that the gage wire of the extension
cord is the correct size wire to carry the current this product will
draw .
An undersized cord is a potential fire hazard, and will cause a
drop in line voltage resulting in loss of power causing the product
to overheat . The following table indicates the correct size cord
for length required and the ampere rating listed on the product
nameplate .
If in doubt, use the next heavier gage cord. The
smaller the gage number, the heavier the wire gage.
Minimum gage for extension cords
Amps Volts Length of cord in feet
120v 25
50
100 150
200 250 300 400 500
240v 50
100 200 300 400 500 600 800 1000
0-2
18
18
18
16
16
14
14
12
12
2-3
18
18
16
14
14
12
12
10
10
3-4
18
18
16
14
12
12
10
10
8
4-5
18
18
14
12
12
10
10
8
8
5-6
18
16
14
12
10
10
8
8
8
6-8
18
16
12
10
10
8
6
6
6
8-10
18
14
12
10
8
8
6
6
4
10-12
16
14
10
8
8
6
6
4
4
12-14
16
12
10
8
6
6
6
4
2
14-16
16
12
10
8
6
6
4
4
2
16-18
14
12
8
8
6
4
4
2
2
18-20
14
12
8
6
6
4
4
2
2
Electromagnetic Interference (EMI)
The system is designed to avoid electromagnetic emissions
interference with surrounding electrical equipment . Due to
the vast assortment of electrical equipment available, it is
possible that some interference may be experienced by the end
user . If interference is experienced, the device that is creating
interference should be removed from the room where the
generator is located . If the interference persists, then it may be
necessary to confirm that both devices are connected to isolated
circuits . If the problem still occurs, then the two devices should
be moved as far apart as possible . Finally, if the problem cannot
be eliminated, contact Gast Manufacturing .
Electrical Installation
WARNING
Incorrect electrical connection may result in electric
shock. The electrical connection must be carried out in
accordance with local electrical regulations and by qualified
personnel. Earthing of all AC models must be ensured during
installation. The capacitor must be earthed, as failure to do
so may cause electric shock when touched. Plug the system
into an earthed socket of nominal voltage and ensure that
fusing is adequate.
• For electrical connection, refer to schematic in back of this
manual .
• Check system serial number label for frequency and voltage
to ensure that it corresponds to the voltage and frequency
used for the system .
• Minimum of 15 Amp rating on circuit breakers .
Operation
• If the temperature of the system is extremely low (for
instance after transportation or stocking), allow system to get
to room temperature before switching on the system .
• Do not use system for compression of liquids and dangerous
gases, such as petrol vapour and solvents .
• Do not lubricate the oil-less system with oil, as this will
destroy important components .