Low

High

Pump

Motor

Excess

Reason and remedy

Vacuum

Pressure

Vacuum

Pressure

Overheat

Overload

Noise

for problem.

TROUBLESHOOTING CHART

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

PART NO. 70 - 3005 G443PL (Rev. D)

Gast Manufacturing, Inc.

2300 S. Highway M139

Benton Harbor, MI,49022

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

Gast Hong Kong

Room 6/9.,

New Commerce Centre

19 On Sum St., Shatin

N. T. Hong Kong

Ph: (852) 2690 1066

Fax: (852) 2690 1012

www.gasthk.com

For the name of the nearest authorized service facility, contact one of our offices below or visit our website

at www.gastmfg.com.

Filter dirty. Clean or replace.
Muffler dirty. Clean or replace.
Valves dirty or valves bent.

Clean or replace.
Relief valve set too high.

Inspect and adjust.
Relief valve set too low.

Inspect and adjust.
Plugged vacuum/pressure line.

Inspect and repair.
Collapsed vacuum line.

Inspect and repair.
Low voltage, wonʼt start.

Check power source.
Voltage wrong.

Check power source.
Cylinder misadjustment.

Realign.
Leaky hose or check valve.

Replace.
Dirt or liquid on top of piston.

Inspect and clean.
Motor not wired correctly.

Check wiring diagram/line voltage.
Blown head gasket.

Replace.

At Pump

At pump

At pump

At pump

At pump

European Sales & Service
Headquarters

Gast Group Limited

A Unit of IDEX Corporation

Unit 11, The I O Centre

Nash Road

Redditch B98 7AS

United Kingdom

Tel: +44 (0) 1527 504040

Fax: +44 (0) 1527 525262

www.gastmfg.com

www.jun-air.com

Содержание 70 - 3005 G443PL

Страница 1: ...s and requires NO lubrication Pressure units may be used for both pressure and vacuum Consult your Gast Distributor Representative to use vacuum units for pressure Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free serv...

Страница 2: ...ow over the product in any way can cause the product to overheat Mounting This product can be installed in any orientation Mounting the product to a stable rigid operating surface and using shock mounts will reduce noise and vibration Accessories Filters and mufflers are supplied with some models These should be checked periodically and replaced when necessary Please consult your Gast Distributor ...

Страница 3: ...ped with a power supply cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Extension cords Use only a 3 wire extension cord that has a 3 blade grounding plug Connect extension cord plug to a matching 3 slot receptacle Do not use an adapter Make sure your ex...

Страница 4: ...peration This one procedure will help to assure the productʼs performance and service life Solvent Cleaning Use only Gast recommended Solvent or other non petroleum based solvent Do Not use kerosene or ANY other combustible solvent to clean product 1 Remove the four bolts holding the head on 2 Remove filters and clean with Gast recommended solvent or other non petroleum based solvent Use compresse...

Страница 5: ...NTY IS LIMITED SOLELY AT GASTʼS OPTION TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON DELIVERED GOODS OR RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND IN NO EVENT SHALL EXCEED THE PRICE OR CHARGE FOR SUCH GOODS GAST EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE ...

Страница 6: ...FAN DAA 1 AF533A 14 GRILLE 1 AF807 2 AF807 15 RIVET 4 AP534 8 AP534 16 VALVE PLATE ASSEMBLY 1 AP519 2 AP519 17 CRANKCASE COVER 1 AP526 2 AP526 18 CRANKCASE COVER SCREW 2 AP525 4 AP525 SERVICE KIT 1 K294A 2 K294A DAA DOA DOL SERIES Please reference the exploded views on the next page for the following model and parts table DOA shown The double ended DAA models not illustrated are two DOAs mounted b...

Страница 7: ...EXPLODED PRODUCT VIEWS MODEL DOA VALVE PLATE ASSEMBLY Valve Plate Assembly available separately Valve Plate Assembly also includes items 7 8 as shown in the main exploded view 7 ...

Страница 8: ... replace Muffler dirty Clean or replace Valves dirty or valves bent Clean or replace Relief valve set too high Inspect and adjust Relief valve set too low Inspect and adjust Plugged vacuum pressure line Inspect and repair Collapsed vacuum line Inspect and repair Low voltage wonʼt start Check power source Voltage wrong Check power source Cylinder misadjustment Realign Leaky hose or check valve Repl...