Gast 6066 SERIES Скачать руководство пользователя страница 2

Motor Control

It is your responsibility to contact a qualified

electrician to assure that the electrical installation is ade-

quate and in conformance with all national and local codes

and ordinances.
Determine the correct overload setting required to protect

the motor (see motor starter manufacturerʼs recommenda-

tions). Select fuses, motor protective switches or thermal

protective switches to provide protection. Fuses act as

short circuit protection for the motor, not as protection

against overload. Incoming line fuses help to withstand

the motorʼs starting current. Motor starters with thermal

magnetic overload or circuit

breakers protect motor from overload or reduced

voltage conditions.
The wiring diagram supplied with the product provides

required electrical information. Check that power source is

correct to properly operate the dual-voltage motors.

Correct installation is your responsibility. Make sure you

have the proper installation conditions and that installa-

tion clearances do not block air flow. Proper guards

should be installed to prevent contact with moveable

parts of this pump. Do Not lift the unit by the fan shroud.

The unit should be lifted by means of the eye bolt.

Blocking air flow over the product in

any way can cause the product to overheat.

Some models are equipped with glass

jars. Proper measures should be taken to guard against

the fragmenting or braking of glass if an alternative mate-

rial is not used. If hazard is ignored severe personal

injury or death can occur.

INSTALLATION

Accessories

The productʼs internal intake and exhaust filters will pro-

vide adequate filtration in most applications. Check filters

periodically and replace when necessary. All units should

have an intake and exhaust filter to prevent contaminants

from entering the pump or the pneumatic system. Please

consult your Gast Distributor/Representative for additional

filter recommendations.

c

Disconnect electrical power at the circuit breaker
or fuse box before installing this product.

Install this product where it will not come into
contact with water or other liquids.

Install this product where it will be weather
protected.

Electrically ground this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

Plumbing

Remove plugs from the IN and OUT ports. Connect with

pipe and fittings that are the same size or larger than the

productʼs threaded ports.

Install relief valves and gauges at inlet or outlet, or both, to

monitor performance. Check valves may be required to

prevent back streaming through the pump.

WARNING

DANGER

Your safety and the safety of others

is extremely important.

We have provided many important safety messages
in this manual and on your product. Always read
and obey all safety messages.

This is the safety alert symbol. This symbol

alerts you to hazards that can kill or hurt you and
others. The safety alert symbol and the words
“DANGER” and “WARNING” will precede all safety
messages. These words mean:

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the safety instructions are not
followed.

2

Grounded Plug

Grounding Pin

Grounded Outlet

120-volt grounded connectors

shown. 220/240-volt grounded

connectors will differ in shape.

DIAGRAM A

Electrical Connection

Mounting

This product can be installed in any orientation. Mounting the

product to a stable, rigid operating surface and using shock

mounts will reduce noise and vibration.

CAUTION

WARNING

Содержание 6066 SERIES

Страница 1: ...rotect all surrounding items from exhaust air This exhaust air can become very hot Corrosive gases and particulate material will damage unit Water vapor oil based contaminants or other liquids must be filtered out Consult your Gast Distributor before using at high altitudes Oil Less rotary vanes require NO lubrication Sealed bearings are grease packed Use of petroleum or hydrocarbon products will ...

Страница 2: ...filter to prevent contaminants from entering the pump or the pneumatic system Please consult your Gast Distributor Representative for additional filter recommendations c Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other liquids Install this product where it will be weather prote...

Страница 3: ... Power supply wiring must conform to all required safety codes and be installed by a qualified person Check that supply voltage agrees with that listed on product nameplate Be sure the 3 phase motor turns in the proper direction of rotation after installation Turning in the wrong direc tion will drastically reduce vane life Extension cords Use only a 3 wire extension cord that has a 3 blade ground...

Страница 4: ... and exhaust ports 10 Replace filter before resuming operation Check intake and exhaust filters after first 500 hours of operation Clean filters and determine how frequently filters should be checked during future operation This one procedure will help to assure the productʼs perform ance and service life Clean filters when necessary by removing and washing in a solvent or soap and water After cle...

Страница 5: ...en place one of the new bearings in the seat Using an arbor press press the bearing onto the shaft Be careful to press only on the inner bearing race Tighten the pump body bolts 7 Install the new vanes supplied with the kit Be careful to face the vane bevels in the proper direction as noted in step 2 8 Perform step 6 from Minor Rebuild 9 Install the belleville springs with the washer between them ...

Страница 6: ...VE 1 AK736 AK736 17 IFAN GUARD ASSM DEAD 1 AK737 AK737 18 INTAKE FILTER ASSEMBLY 1 AD560 AD560 19 MUFFLER ASSEMBLY 1 AD560C 20 COVER GASKET 1 AD562 2 AD562 21 JAR 1 AD563A 2 AD563A 22 FILTER ELEMENT ASSEMBLY 1 AD750 2 AD750 23 FILTER FELT 1 AD752 2 AD752 24 BODY SPACER 1 AE315B 2 AE315B 25 KEY COUPLING 1 AE136D AE136D 26 COUPLING ASSEMBLY 1 AE765 AE765 27 CHECK VALVE NOT SHOWN 1 AH326B AH326B SERV...

Страница 7: ...UENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOO...

Страница 8: ...eck wiring diagram and line voltage Running at too high an RPM Check wiring diagram and line voltage www gastmfg com ISO 9001 14001 CERTIFIED We have Gast Certified Service Centers throughout the world For the most up to date listing contact one of our sales offices below Gast Hong Kong Room 6 9 F New Commerce Centre 19 on Sum Street Shatin N T Hong Kong Ph 852 2690 1066 Fax 852 2690 1012 www gast...

Отзывы: