Gast 23 Series Скачать руководство пользователя страница 3

It is your responsibility to: 
•  Regularly inspect and make necessary repairs to

product in order to maintain proper operation.  

•  Make sure that pressure and vacuum is released 

from product before starting maintenance.

Check intake and exhaust filters after first 500 hours of
operation.  Clean filters and determine how frequently
filters should be checked during future operation.  This
one procedure will help to assure the product’s
performance and service life.

General Maintenance

1.

Remove end cap and filters.  Inspect filters for 
rips,tears, cuts, brittleness and excessive foreign 
material.

2.  Clean filters if in good condition with

compressed air.  Re-inspect for wear conditions.
Set filters aside.

3.  Check filter/muffler (#11) for compacted debris.  If

debris is present, replace filter/muffler.

4.  Check condition of O-ring.  It should be soft and

flexible.  Replace if it is not.

5.  Remove and inspect muffler box.  Clean box.  Set

box aside.  (Not all models have a muffler box.)

6.  Check gasket for cracks or tears.  Install new gasket

if any cracks or tears appear.  Replace gasket.

7.   Replace muffler box.
8.   Reinstall filters or install new filters if required.

Reinstall end cap.

MAINTENANCE

Option 2

1.   Remove six end plate bolts.  (See exploded view.)
2.  Use a small hammer to carefully tap on end plate to 

remove.  Do not use a screwdriver to pry off.

3.   Check that vanes are moving freely in and out of 

vane slots.  Replace vanes if more than 50% of the
vane extends past the vane slot.

4.   Remove vanes and clean both sides with fine emery

cloth.  Clean end-plate with fine emery cloth.

5.   Flush vanes with AH255B solvent and remove all

solvent from vanes.

6.   Flush body, rotor and end plate with AH255B 

solvent, then remove all solvent from each part.

7.   Check body, rotor and end plate for scoring.  If each

part is clean and shows no signs of scoring,
re-install parts.  If scoring appears, send unit to 
factory or replace with new part(s).

Check that all external accessories such as relief
valves and gauges are attached to cover and are
not damaged before re-operating product.

Flushing

Flushing this product to remove excessive dirt, foreign
particles, moisture or oil that occurs in the operating
environment will help to maintain proper vane
performance.  There are 2 options for this operation.
If Option 1 does not remedy your problem, go on to
Option 2.

Use only Gast AH255B Flushing Solvent or other
non-petroleum based flushing solvent.  Do Not use
kerosene or ANY other combustible solvents to
flush product.

Disconnect electrical power supply cord before
performing maintenance on this product.

If product is hard wired into system, disconnect
electrical power at the circuit breaker or fuse box
before performing maintenance on this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

Electrical Shock Hazard

WARNING

Option 1

You will need 2 pipe nipples at least 4 inches long with
1/4” NPT for 0323 and 0523 products, or 3/8” NPT on
one end for 0823 and 1023 products.  No nipples are
needed if the unit does not have a muffler box.
1. Remove filter and muffler cap (#9).
2. Remove 5 bolts.  Use a small hammer to tap on

muffler box to remove it.  Attach pipe nipples
where muffler caps were removed.

3.   Start product and add flushing solvent to the inlet

port. If using liquid solvent, pour several
tablespoons directly into the inlet port.  If using Gast

AH255B, spray solvent for 5-10 seconds into inlet

port.  Place towel over exhaust port to clean up
solvent.

4.  Plug inlet port for 20-30 seconds.  Listen for 

changes in the sound of the pump.  If pump sounds 
smooth, go to next step.  If pump does not sound 
like it is running smoothly, installing a Service Kit will
be required (See Service).  

5. Release vacuum.
6.  Repeat steps 3-5 three or four times.

If Option 1 is not successful, remove the end plate
and examine.

Injury Hazard

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Flush this product in a well ventilated area.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

Содержание 23 Series

Страница 1: ...ce carbon vane service life Model 0523 101 Shown Model 1023 101Q Shown IMPORTANT PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free service General information Clear...

Страница 2: ...tached to the product provides required electrical information Check that power source is correct to properly operate the dual voltage motor It is your responsibility to operate this product at recommended pressures or vacuum duties and room ambient temperatures Start Up If motor fails to start or slows down significantly under load shut off and disconnect from power supply Check that the voltage ...

Страница 3: ...d are not damaged before re operating product Flushing Flushing this product to remove excessive dirt foreign particles moisture or oil that occurs in the operating environment will help to maintain proper vane performance There are 2 options for this operation If Option 1 does not remedy your problem go on to Option 2 Use only Gast AH255B Flushing Solvent or other non petroleum based flushing sol...

Страница 4: ...t is your responsibility to follow proper shutdown procedures to prevent product damage NEVER ADD OIL TO THIS OIL LESS PUMP 1 Disconnect plumbing 2 Operate product for at least five minutes without plumbing 3 Run at maximum vacuum for 10 15 minutes 4 Repeat step 2 5 Disconnect power supply 6 Plug open ports to prevent dirt or other contaminants from entering product Ꮨ Disconnect electrical power s...

Страница 5: ...02 4 END PLATE 1 AK516A AK501 AK516A AK501 AK516A 5 GASKET 1 AK521 AK521 6 MUFFLER BOX 1 AK519 AK519 7 O RING 2 AK473 AK473 8 FELT 2 AK524 AK524 9 END CAP 2 AK510 AK510 10 END CAP ASSEMBLY 2 AK526 AK526 11 FILTER MUFFLER 1 AK840A AK840A 12 FOOT SUPPORT 1 AC136 AC136 13 ELBOW 2 AD997 14 MUFFLER ASSEMBLY 1 V425L 15 JAR 2 AA125A 16 COVER 1 AV427 17 FELT FILTER 4 B344A 18 SUPPORT 1 B345A 19 COVER GASK...

Страница 6: ...ASSEMBLY 1 AB599B 13 a NIPPLE 2 BA714 BA714 14 JAR 2 AA805 15 COVER GASKET 2 AA405 16 COVER ASSEMBLY 1 AV805BPC 17 MUFFLER ASSEMBLY 1 AC434 1 18 COUPLING 2 AC391 19 CARTRIDGE 2 AC393 20 END CAP ASSEMBLY 2 AC394 21 MUFFLER PLATE 1 AC395 22 STUD 2 AC396 23 FILTER ASSEMBLY 1 AB599 24 COVER ASSEMBLY 1 AV805APC 25 FILTER ASSEMBLY 1 AC433 1 SERVICE KIT 1 K479A K479 K479A K479 K575A K575A For 1423 Models...

Страница 7: ...OR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY...

Страница 8: ......

Отзывы: