![Gast 23 Series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/gast/23-series/23-series_operation-and-maintenance-manual_568603003.webp)
It is your responsibility to:
• Regularly inspect and make necessary repairs to
product in order to maintain proper operation.
• Make sure that pressure and vacuum is released
from product before starting maintenance.
Check intake and exhaust filters after first 500 hours of
operation. Clean filters and determine how frequently
filters should be checked during future operation. This
one procedure will help to assure the product’s
performance and service life.
General Maintenance
1.
Remove end cap and filters. Inspect filters for
rips,tears, cuts, brittleness and excessive foreign
material.
2. Clean filters if in good condition with
compressed air. Re-inspect for wear conditions.
Set filters aside.
3. Check filter/muffler (#11) for compacted debris. If
debris is present, replace filter/muffler.
4. Check condition of O-ring. It should be soft and
flexible. Replace if it is not.
5. Remove and inspect muffler box. Clean box. Set
box aside. (Not all models have a muffler box.)
6. Check gasket for cracks or tears. Install new gasket
if any cracks or tears appear. Replace gasket.
7. Replace muffler box.
8. Reinstall filters or install new filters if required.
Reinstall end cap.
MAINTENANCE
Option 2
1. Remove six end plate bolts. (See exploded view.)
2. Use a small hammer to carefully tap on end plate to
remove. Do not use a screwdriver to pry off.
3. Check that vanes are moving freely in and out of
vane slots. Replace vanes if more than 50% of the
vane extends past the vane slot.
4. Remove vanes and clean both sides with fine emery
cloth. Clean end-plate with fine emery cloth.
5. Flush vanes with AH255B solvent and remove all
solvent from vanes.
6. Flush body, rotor and end plate with AH255B
solvent, then remove all solvent from each part.
7. Check body, rotor and end plate for scoring. If each
part is clean and shows no signs of scoring,
re-install parts. If scoring appears, send unit to
factory or replace with new part(s).
Check that all external accessories such as relief
valves and gauges are attached to cover and are
not damaged before re-operating product.
Flushing
Flushing this product to remove excessive dirt, foreign
particles, moisture or oil that occurs in the operating
environment will help to maintain proper vane
performance. There are 2 options for this operation.
If Option 1 does not remedy your problem, go on to
Option 2.
Use only Gast AH255B Flushing Solvent or other
non-petroleum based flushing solvent. Do Not use
kerosene or ANY other combustible solvents to
flush product.
Ꮨ
Disconnect electrical power supply cord before
performing maintenance on this product.
If product is hard wired into system, disconnect
electrical power at the circuit breaker or fuse box
before performing maintenance on this product.
Failure to follow these instructions can result in
death, fire or electrical shock.
Electrical Shock Hazard
WARNING
Option 1
You will need 2 pipe nipples at least 4 inches long with
1/4” NPT for 0323 and 0523 products, or 3/8” NPT on
one end for 0823 and 1023 products. No nipples are
needed if the unit does not have a muffler box.
1. Remove filter and muffler cap (#9).
2. Remove 5 bolts. Use a small hammer to tap on
muffler box to remove it. Attach pipe nipples
where muffler caps were removed.
3. Start product and add flushing solvent to the inlet
port. If using liquid solvent, pour several
tablespoons directly into the inlet port. If using Gast
AH255B, spray solvent for 5-10 seconds into inlet
port. Place towel over exhaust port to clean up
solvent.
4. Plug inlet port for 20-30 seconds. Listen for
changes in the sound of the pump. If pump sounds
smooth, go to next step. If pump does not sound
like it is running smoothly, installing a Service Kit will
be required (See Service).
5. Release vacuum.
6. Repeat steps 3-5 three or four times.
If Option 1 is not successful, remove the end plate
and examine.
Injury Hazard
Product surfaces become very hot during operation,
allow product surfaces to cool before handling.
Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.
Flush this product in a well ventilated area.
Failure to follow these instructions can result in
burns, eye injury or other serious injury.
WARNING
Содержание 23 Series
Страница 8: ......