Prior to assembling your appliance, the following must be 
reviewed. Compliance with the following should result in 
satisfactory heater operation. This instruction manual should 
be retained for future reference. The installation must 
conform with local codes or authority having jurisdiction.

1.   The heater is intended for residential and non-residential 

outdoor spaces.  The installation must conform with 
local codes or, in the absence of local codes, with the 
Australian Standard AS 5601.

2.  Adequate clearance around air openings into the 
 

combustion chamber, clearances from combustible  

 

 

materials, provisions for accessibility and for  

 

 

 

combustion and ventilating air supply must be    

 

 

maintained at all times when the appliance is operating.

INSTALLATION

3.  Proper clearance from combustible materials must be    
 

maintained at all times. The minimum clearances are  

 

 

as follows:

 

Minimum Clearance from Combustibles:

 

Side

  

500 mm 

 

Rear 

  500 mm

 

Ceiling 

  500 mm  

 

Below 

  500 mm

Combustible materials are considered to be wood,    
compressed paper, plant fibres, plastic, plexiglas or 
other materials capable of being ignited and burned. 
Such materials shall be considered combustible even 
though flame proofed, fire-retardant treated or plastered. 
Additional clearance may be required for glass, painted 
surfaces and other materials which may be damaged by 
radiant or convection heat.

4.  Heaters must be placed on a level and adequate footing   
and be readily accessible.

PROPANE GAS

5.  The gas manifold supply pressure must be regulated 
 

at 2.75 kPa utilising an AGA approved regulator  

 

 

(supplied with heater).

NATURAL GAS

6.  The gas manifold supply pressure must be regulated at    
 

1.0 kPa utilising an AGA approved regulator.

 

a.   The appliance area must be kept clear and free of  

 

 

    combustible materials, gasoline and other flammable   

 

  vapours and liquids.

 

b.    Gas orifices and burner must be kept clear of dirt and 

cobwebs. Flow of combustion and ventilation air to 
the heater must not be obstructed.  Cleaning with a 
soft brush before use and at least every six months is 
recommended.

 

c.   All gas connections should be checked for leaks 

utilising a soap solution. Never use a flame for this 
purpose.

 

d.   The flame pattern should be visually checked 

whenever heater is operated. 

 

    If flames extend beyond the mesh

 

    or black spot is accumulating on the mesh    

 

 

    the heater should be turned off  

 

 

 

 

    immediately. The heater should not be operated again  

 

    until the unit is serviced and or repaired.

 

e.   Any cleaning agent used on the heater should be of a 

non-combustible and non-corrosive nature.

Important Safety Rules:

This appliance must only be used in a well ventilated 
area.

1.  This appliance shall not be installed or used indoors, in  
 

buildings, garages or any other enclosed area.

2. 

DO NOT

 place articles on or against this appliance.

3. 

DO NOT

 use or store flammable materials near  

 

this appliance. 

4.

 

Children and adults should be alerted to the hazards of  

 

high surface temperatures, burns and clothing ignition.

5.  Children should be carefully supervised when they  
 

are in the area of the appliance.

6. 

NEVER

 hang anything including clothes or other 

 

flammable items on the appliance.

7. 

 

DO NOT

 operate this appliance unless it is fully 

 

assembled with burner guard in place.

8.  

DO NOT SPRAY AEROSOLS IN THE VICINITY  

  OF THIS APPLIANCE WHILE IT IS IN    
  OPERATION.

9.  Installation and repair should be done by a qualified  
 

service person. The appliance must be inspected  

 

before use and at least annually by a qualified service  

 

person.  It is imperative that control compartment,  

 

burners and circulating air passages of the heater be  

 

kept clean.

Содержание RH1039 Series

Страница 1: ...ns for future use 02314 01 08 FOR OUTDOOR UNDERCOVER USE ONLY PROPANE GAS NATURAL GAS THIS APPLIANCE MUST NOT BE INSTALLED OR USED INDOORS NATURAL GAS APPLIANCE TO BE INSTALLED ONLY BY AN AUTHORISED PERSON THE AUTHORISED PERSON WILL PROVIDE A CERTIFICATE OF COMPLIANCE NOTE TO INSTALLER TEST OPERATION OF APPLIANCE BEFORE LEAVING RH1039 SERIES 3 TILE HEATER Operates for approximately 15hrs on a prop...

Страница 2: ...lising an AGA approved regulator a The appliance area must be kept clear and free of combustible materials gasoline and other flammable vapours and liquids b Gas orifices and burner must be kept clear of dirt and cobwebs Flow of combustion and ventilation air to the heater must not be obstructed Cleaning with a soft brush before use and at least every six months is recommended c All gas connection...

Страница 3: ...indoors the propane cylinder and the heater must be disconnected and the cylinder stored in accordance with the Standard for Storage and Handling of Liquefied Gases Any modification to the heater not described in the installation instructions may compromise the safety of this appliance Special concern is as follows 1 DO NOT bypass thermocouple safety burner 2 DO NOT operate heater without the guar...

Страница 4: ...ter is tampered with or altered To have these units altered or serviced by an unauthorised person may render the product inefficient and at worst dangerous SERVICING INSTRUCTIONS Appliances should be serviced at least annually and servicing must only be carried out by a Licensed Plumber or Authorised Person 1 Remove Guard from Burner Housing 2 Clean the Burner Ports and top with a Soft Brush Inspe...

Страница 5: ...aces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned TOP CLEARANCE 500mm CLEARANCE 2500mm OFF CORD IGNITION CORD GAS CONNECTION POINT 2450mm 400mm 3 Tile 510mm 5 Tile 710mm 230m m ...

Страница 6: ...tenance can cause injury or property damage Any modifications or adjustments made to product without prior authority from the manufacturer will void any warranty claims Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment LIGHTING INSTRUCTIONS Warning White smoke may appear around the radiant head during the first minutes of the init...

Страница 7: ... see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at least 30 of the remaining wall area is open and unrestricted see Example 4 5 In the case of balconies at least 20 ...

Страница 8: ...Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www sitro com au AberGas Ltd Hamilton N Z www abergas co nz ...

Отзывы: