background image

5

4

Electrical Data

IMPORTANT

This product is fitted with a sealed electrical connection plug that is compatible with the heater, the mains supply for 

Australia and meets the requirements of international standards. This heater must be connected to a supply voltage 

that is equal to that stated on the rating label. If the mains connection plug or power cord becomes damaged it must be 

replaced with a complete assembly that is identical to the original, and this must be replaced by an authorised service 

centre. Always follow the Australian requirements for connection to the mains supply.  If in doubt always consult a 

qualified electrician.
Note: EH633 + EH633R (3200W) requires installation of a 15AMP socket by a qualified electrician before use.

Technical Specification

MODEL

EH613/EH613R/B

EH623/EH623R/B

EH633/EH633R/B

Remote Control

No / Yes

No / Yes

No / Yes

Voltage

220-240V AC ~ 50Hz

220-240V AC ~ 50Hz

220-240V AC ~ 50Hz

Input Wattage

1800W

2400W

3200W (15AMP)

Unit Weight

6.8Kg/7.5Kg

7.5Kg/8.2Kg

9.0Kg/9.7Kg

IP Rating

IPx4

IPx4

IPx4

Heater specifications can be found on the data label. 

B = BLACK COLOUR

Assembly

HEATER HEAD

Attach the heater rear bracket (B) to the heater body (A) using bolts, washers and nuts. You can either mount side or 

lengthways depending on the mounting surface.

Mounting Bolts

Mounting Nuts 

and Washers

Mounting Bolts

To adjust mounting bolts, 

remove nut and slide 

mounting bolts between units 

mounting bolt groove then 

fit bracket, replace nut and 

tighten.

(B) Heater Rear 

Bracket

(B) Heater Rear 

Bracket

(A) Heater Body

Содержание OPTIMUM EH633R

Страница 1: ...deal for use in alfresco areas verandahs and garages EH633 EH633R requires 15A power point to be installed by qualified electrician 03455 05 16 Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www gasmate com au Aber Holdings Ltd N Z www gasmate co nz OPTIMUM RADIANT HEATER EH600 SERIES Important Retain these instructions for future use 03240 07 16 ...

Страница 2: ... facility Extension Cords and Reels This heater is NOT designed to run off an extension cord If you require an additional power point please have one installed by a qualified electrician The use of extension cords may cause power voltage loss which will result in damage to the appliance this will NOT be covered under warranty Installation Always ensure you select the correct fixing accessories whi...

Страница 3: ...le system with this heater DO NOT clean the heater while the heater is on or plugged into the mains power supply DO NOT touch any part of the heater while on hot surfaces may burn DO NOT use the wall heater as a dryer DO NOT attempt to modify the heater power cord power plug or the supplied accessories in any way DO NOT expose the heater to rain water or use in damp wet conditions NEVER cover this...

Страница 4: ...0W requires installation of a 15AMP socket by a qualified electrician before use Technical Specification MODEL EH613 EH613R B EH623 EH623R B EH633 EH633R B Remote Control No Yes No Yes No Yes Voltage 220 240V AC 50Hz 220 240V AC 50Hz 220 240V AC 50Hz Input Wattage 1800W 2400W 3200W 15AMP Unit Weight 6 8Kg 7 5Kg 7 5Kg 8 2Kg 9 0Kg 9 7Kg IP Rating IPx4 IPx4 IPx4 Heater specifications can be found on ...

Страница 5: ...on heater in front of a power point 3 Mark and drill 2 mounting holes for bracket C 4 Using 2 suitable screws not supplied attach the bracket to the wall or ceiling Note If unsure what screws to use please discuss with your local hardware store 5 Using the nuts and bolts join the bracket C to the heater bracket B and tighten fully 6 Heater is now mounted and ready for use Check the safety distance...

Страница 6: ...eved 5 Insert and tighten the locking bolt if possible to stop any unintentional movement of the heater Note If locking bolt can not be fitted ensure the head tilt bolt is very tight Head Tilt Bolt 30 Ceiling Mount with Chain Only use this mounting option if your ceiling is too high 1 Attach the bracket C as noted below 2 Cut chain D not supplied to desired length 3 Using nut and bolt attach chain...

Страница 7: ...elow a power point 4 If heater is facing another vertical surface example wall the gap must be at least 1 metre 5 Never mount heater within 1 metre of a water source example tap NOTE Never mount heater into the wall or ceiling Only mount to the surface eave ceiling floor 1 8 m wall eave ceiling minimum 1 8m wall 200mm 90 1m minimum 200mm floor wall heater NO eave ceiling heater 1 8m minimum NO ...

Страница 8: ...THE STANDBY MODE TURN ON 1 Plug into 240V AC wall socket 2 Switch the wall socket on 3 Turn the unit switch on it will glow Red Standby Function On 4 Using the remote press ON the heater will come on and a small blue LED will glow TURN OFF 1 Using the remote press OFF the heater will turn off and the small LED light will go out 2 Turn the unit switch off the red LED will go out 3 Switch the wall s...

Отзывы: