background image

2

3

2

3

INSTALLATION

Important Safety Rules:
This appliance must only be used in a well ventilated

area.

1. This appliance shall not be installed or used indoors,   
  in buildings, garages or any other enclosed area.

2. 

DO NOT

 place articles on or against this appliance.

3. 

DO NOT use or store flammable materials near this   

  appliance.

4. Children and adults should be alerted to the hazards   
  of high surface temperatures, burns and clothing  

 

  ignition.

5. Children should be carefully supervised when they    

  are in the area of the appliance.

6. 

NEVER

 hang anything including clothes or other

  flammable items on the appliance.

7. 

DO NOT

 operate this appliance unless it is fully

  assembled with reflector in place.

8. 

DO NOT SPRAY AEROSOLS IN THE VICINITY OF  

  THIS APPLIANCE WHILE IT IS IN OPERATION.

9. Installation and repair should be done by a qualified
  service person. The appliance must be inspected
  before use and at least annually by a qualified  

 

  service person. More frequent cleaning may be  

 

  required as necessary. It is imperative that control    

  compartment, burners and circulating air passages    
  of the appliance and light be kept clean.

Prior to assembling your appliance, the following must be

reviewed. Compliance with the following should result in
satisfactory appliance operation. This instruction manual

should be retained for future reference. The installation

must conform with local codes or authority having 
jurisdiction.

1.  The appliance is intended for residential and   

 

 

nonresidential outdoor spaces. The installation  

 

 

must conform with New Zealand Standard 5261 “Gas  

 

Installations”.

2.  Adequate clearance around air openings into the

 

combustion chamber, clearances from combustible

 

materials, provisions for accessibility and for

 

combustion and ventilating air supply must be

 

maintained at all times when the appliance is  

 

 

operating. 

3.  Proper clearance from combustible materials must be

 

maintained at all times. The minimum clearances are

 

as follows: 

Minimum Clearance from Combustibles:

 

Sides

 600 mm   

 

Rear

 600 mm

Ceiling

 900 mm 

 

Installation, Operation and Maintenance Instructions

Combustible materials are considered to be wood,
compressed paper, plant fibres, plastic, plexiglas or
other materials capable of being ignited and burned.
Such materials shall be considered combustible even
though flame proofed, fire-retardant treated or plastered.
Additional clearance may be required for glass, painted
surfaces and other materials which may be damaged by

radiant or convection heat.

4.  The appliance must be placed on a level and adequate
 

footing and be readily accessible.

5.  The gas manifold supply pressure must be regulated
 

at 2.75 kPa utilising an approved regulator

 

(supplied with appliance).

6.  The appliance must be inspected before each use, and
 

at least annually by a qualified service person.

 

a. The appliance area must be kept clear and free of

 

  combustible materials, gasoline and other   

 

 

  flammable vapours and liquids.

 

b. Gas orifices and burner must be kept clear of dirt

 

  and cobwebs. Flow of combustion and ventilation    

 

  air through the perforated portions of the appliance  

 

  must not be obstructed. Cleaning with a soft  

 

 

  brush before use and at least every six months is   

 

  recommended.

 

c. All gas connections should be checked for leaks

 

  utilising a soap solution. Never use a flame for this

 

  purpose.

 

d. The flame pattern at the emitter grid should be

 

  visually checked whenever the appliance is  

 

 

  operated. If flames extend beyond surface of the    

 

  emitter grid or black soot is accumulating on the    

 

  emitter grid or reflector, the appliance should  

 

 

  be turned off immediately. The appliance should not  

 

  be operated again until the unit is serviced and or   

 

  repaired. 

 

e. Any cleaning agent used on the appliance should be

 

  of a non-combustible and non-corrosive nature.

 

  Warm soapy water is ideal. While washing the

 

  appliance, be sure to keep the area around the    

 

  burner and pilot assembly dry at all times. If the    

 

  gas control is exposed to water in any way, do NOT  

 

  try to use it. The appliance should be regularly  

 

 

  cleaned and protected to reduce oxidation, ideally a  

 

  cover should be used when not in use. 

 

f. The emitter grid normally does not require cleaning

 

  and should 

NEVER be painted. The reflector may   

 

  be cleaned, but never painted.

Содержание Infeno GM124-013

Страница 1: ... this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the instructions thoroughly before installing or servicing this equipment FOR OUTDOOR USE ONLY OPERATES ON LPG TM CARBON MONOXIDE HAZAR This appliance can produce carbon monoxide which has no odour Using it in an enclosed space eg boat caravan tent car ca...

Страница 2: ...m Ceiling 900 mm Installation Operation and Maintenance Instructions Combustible materials are considered to be wood compressed paper plant fibres plastic plexiglas or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or plastered Additional clearance may be required for glass painted surfaces and oth...

Страница 3: ...ich include a tip over switch and a flame safeguard system which means if the pilot goes out the unit will automatically turn off REGULATOR SAFETY FEATURE All QCC regulators the part that attaches to the gas cylinder to regulate the flow of gas have a safety feature included that restricts gas flow in the event of a gas leak You can inadvertently activate this safety feature without having a gas l...

Страница 4: ...positioned for easy access Heat exchange tube has a large heat radiating surface Safety guard protects the full height of the heat exchanger tube Weather resistant heat reflector prevents water from entering the combustion zone and reflects heat down Chimney cover PATIO HEATER For Outdoor Use Only Minimum Clearance from Combustible Surfaces Combustible materials are considered to be wood compresse...

Страница 5: ...any damage to either the cylinder connection or the hose NEVER attempt to use damaged equipment 3 When connecting the hose to the cylinder tighten the nut to a positive stop by hand 4 Open cylinder valve fully If a leak can be heard at either end of the hose turn cylinder off and tighten joint Wait 5 minutes before re testing and use a soapy water solution to check the joint If bubbles appear the ...

Страница 6: ...refully lift heat reflector until entire heat exchange tube is exposed Step 2 After heat exchange tube is fully extended rotate counter clockwise until stopped Step 3 Fully open gas chamber door Remove knob from door and place on control stem Step 4 Locate 3 holes to lock heat exchange tube in place Insert 3 included screws into holes ...

Страница 7: ...nder not included into the base assembly and fix it with fixing chain Attach the regulator to the cylinder turn clockwise to tighten it securely Make sure to check for leaks once the cylinder has been positioned see instructions overleaf to check all hose connections AA not included Battery 1 5V A A Tighten ...

Страница 8: ... this point DO NOT ATTEMPT TO LIGHT THE HEATER STEP 9 Use a solution of soapy water dishwashing liquid and water is fine Brush it on or use a spray bottle as shown in the drawing Ensure the connections have a good coating STEP 10a If the connection is leaking bubbles will start to grow in the soapy solution If this happens shut off the gas supply at the cylinder STEP 10b Tighten the connections usi...

Страница 9: ...er won t light No gas Low gas pressure Blockage in orifice Manual valve not in LOW or HIGH position Note If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired Warning Improper installation adjustment alteration service or maintenance can cause injury or property damage Any modifications or adjustments made to product without prior authority from ...

Страница 10: ...sually checked whenever heater is operated If black soot is accumulating on the emitter grid or reflector the heater should be turned off immediately The heater should not be operated again until the unit is serviced and or repaired OPERATING PROCEDURE Note The burner may be noisy when initially turned on To eliminate excessive noise from the burner turn the control knob to the LOW position Then t...

Страница 11: ...ted Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www gasmate com au Aber Hamilton N Z www gasmate co nz Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www sitro com au Aber Hamilton N Z www gasmate co nz SAFE APPLIANCE LOCATIONS This appliance shall only be used in an above ground open air situation with natural ventilation without stagnant areas where gas...

Страница 12: ...12 ...

Отзывы: