19
18
SERVICING INSTRUCTIONS
Appliances should be serviced at least annually and servicing must only be carried out by a Licensed Plumber or
Authorised Person.
Clean the Burner Ports and top with a Soft Brush. Inspect and clean all combustion air inlets, then replace the
Burner ensuring it is firmly secured.
NOTE TO THE INSTALLER
There are two injectors on each valve. The outer injector is for LPG.
1. For natural gas conversion, remove the first injector (LPG) and leave the Natural Gas injector in
place Ensure the Natural gas injector is still tight and in correct position.
2. To adjust the low/turndown flame setting remove the main burner, side burner and rear burner
control knobs using a long thin blade screwdriver to access the “LOW” adjustment screw down
the centre of the valve spindle, turn the screw fully clockwise until it stops then anti clockwise
1/8 of a turn.
• TEST OPERATION OF APPLIANCE BEFORE LEAVING.
• PROVIDE A CERTIFICATE OF COMPLIANCE.
WARNING
• Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
• Read the instructions thoroughly before installing or servicing this equipment.
• THIS APPLIANCE MUST NOT BE INSTALLED OR USED INDOORS.
• NATURAL GAS APPLIANCE. TO BE INSTALLED ONLY BY AN AUTHORISED PERSON.
• THE AUTHORISED PERSON WILL PROVIDE A CERTIFICATE OF COMPLIANCE.
• An AGA approved high flow natural gas regulator must be installed in the pipeline and be set at 1kPa.
NOTE: BBQ MUST BE TESTED. AND PRESSURE MUST BE 1KPA WITH ALL BURNERS RUNNING