2
3
2
INSTALLATION, OPERATION & MAINTENANcE INSTRUcTIONS
INSTALLATION - OUTDOOR USE ONLY
d. The flame pattern at the emitter grid
should be visually checked whenever
heater is operated. If flames extend
beyond surface of the emitter grid or
black spot is accumulating on the emitter
grid or reflector, the heater should be
turned off immediately. The heater should
not be operated again until the unit is
serviced and or repaired.
e. Any cleaning agent used on the heater
should be of a non-combustible and non-
corrosive nature.
f. The stainless steel emitter grid normally
does not require cleaning and should
NEVER
be painted.
7. The hose must be protected from contact
with hot or sharp surfaces both during use
and while in storage. The hose assembly
should be visually inspected prior to each
use of the heater. If excessive abrasion or
wear is evident, or the hose is cut, it must
be replaced prior to operating the heater.
The replacement hose assembly may be
obtained from the manufacturer.
8.
DO NOT
use any pressure regulator or hose
assembly other than those supplied with the
appliance. Replacement pressure regulator
and hose assembly must be those specified.
Replacement parts may be obtained from
the manufacturer or your local sales
representative.
9. Installation and use of this heater must
conform with local codes or, in the
absence of local codes, with the Standards
of Storage and Handling of Liquefied
Petroleum Gases.
10. This heater is designed to operate with
a standard 9Kg propane cylinder with
Approved Cylinder Connection.
11. The valve outlet must be maintained in good
condition. When the cylinder is not in
use, be sure to cover it with a dust cap. A
leak test should be performed with soapy
water whenever connecting a new cylinder.
NEVER
use a match to test for leaks.
12. The gas cylinder must be turned off
whenever the heater is not in use. When
the heater is to be stored indoors, the
propane cylinder and the heater must be
disconnected and the cylinder stored in
accordance with the Standard for Storage
and Handling of Liquefied Gases.
13. The heater has been designed with several
safety features which include a tip over
switch.
Screw the coupling nut of regulator into the
cylinder valve outlet.
POL cYLINDER cONNEcTION DEVIcE
Type of Gas
Propane
Consumption
35 MJ/h
Operating Pressure
2.75 kPa
Injector Size
1.9 mm
Heater specifications can be found on the data
label.
Any modification to the heater not described in
the installation instructions may compromise the
safety of this appliance. Special concern is as
follows:
(1)
DO NOT
shorten post length;
(2)
DO NOT
bypass thermocouple safety;
(2)
DO NOT
operate heater without the reflector;
Clothing or other flammable materials should not
be hung from the heater, or placed on or near
the heater. The area above the burner may be
extremely hot. Direct contact with these metal
surfaces should be avoided in order to prevent
burns or clothing ignition.