background image

HOSE & REGULATOR SAFETY
The regulator and hose assembly supplied with the 
heater are suitable for Propane Gas.
A gas regulator adjusted to have an outlet pressure 
of 2.75kPa is supplied for connection to the 
propane gas cylinder. The pressure regulator and 
hose assembly supplied with the heater must be 
used. Replacement pressure regulators and hose 
assemblies must be those specified by the heater 
manufacturer.
When connecting the hose and regulator assembly 
to the gas cylinder, take care to avoid unnecessary 
twisting of the flexible hose.
After the assembly has been secured, turn on the 
gas and check for leaks by brushing a soap and 
water solution over all connections.
If you are unable to correct the leak by tightening 
the connections, turn off the gas and contact the 
supplier immediately.
Always ensure the heater is kept away from 
flammable materials and the gas cylinder clear of 
any heat source.
When changing over from an empty gas cylinder to 
a full one make sure this procedure is carried out in 
a well ventilated location, preferably outside, away 
from people and away from any sources of ignition; 
such as naked flames, pilot flames, electric heaters/
equipment.
GAS CYLINDER USE & SAFETY
This is a low pressure portable camping heater 
and must only be used with the regulator supplied. 
Your heater is designed for use with 4.5Kg or 9Kg 
propane gas cylinders certified to AS 2469.
The gas cylinder should be filled by a reputable gas 
supplier and visually inspected and requalified at 
each filling.
Always keep cylinder in an upright position.
Always close the cylinder valve when the barbecue 
is not in use.
Do not subject gas cylinder to excessive heat.
NEVER STORE YOUR GAS CYLINDER INDOORS.
If you store your heater indoors, ALWAYS 
disconnect the gas cylinder first and store the 
cylinder safely outside.
Cylinders must be stored outdoors in a well 
ventilated area out of reach of children, and must 
not be stored in a building, garage or any other 
enclosed area.
Check the cylinder collar to ensure the test date 
status is current (10 years from date stamp).

GAS INSTALLATION CODES

•   Heaters must be used in accordance with the 

installation requirements of your gas supply 
authority, or the Australian Standard AS/NZS 
5601.

•   Heater is for use with bottled gas are labelled 

‘Propane Gas’ or ‘ULPG’.

•   Check the gas type sticker attached to the 

heater.

CLEARANCES
Minimum Clearances from combustible materials 
must be:
Rear - 200mm
Sides - 200mm
Above - 500mm

SPECIFICATIONS
Heater specifications can be found on the data label 
attached to the heater body. 
Hose connection thread is 1/4” BSP.  
Maximum Hose Length is 1500mm

CARE & MAINTENANCE
Only use the regulator assembly supplied with the 
appliance for direct connection to the cylinder. 
DO NOT USE ADAPTORS.
DO NOT operate or store the appliance outdoors 
when raining. If exposed to rain tilt the appliance to 
allow any water ingress to escape.

 

    IMPORTANT

Ensure the appliance is set up on a level 
ground.
Never block or cover any of the ventilation 
holes, air inlet or air outlet. If any of these are 
cover poisonous CO and CO2 may built up to 
a hazardous level and may cause death.
Do not move the appliance while in use or 
when hot.
Before connecting and disconnecting to gas 
source, make sure burner control is in OFF 
position.
CAUTION: When the appliance is not in use, 
the gas must be turned off at the cylinder or 
the cartridge is disconnected.
Accessible parts may become hot. Keep 
young children away!

Содержание CH203

Страница 1: ...ed safety device which senses oxygen levels and switches off the entire unit when at a low level Includes safety tip over switch that halts the supply of gas to the unit should it be accidentally knoc...

Страница 2: ...ply assembly This appliance must not be used indoors DO NOT subject gas cylinder to excessive heat USE OUTDOORS ONLY This appliance shall only be used with an LPG cylinder certified to AS2469 IT MAY B...

Страница 3: ...not subject gas cylinder to excessive heat NEVER STORE YOUR GAS CYLINDER INDOORS If you store your heater indoors ALWAYS disconnect the gas cylinder first and store the cylinder safely outside Cylind...

Страница 4: ...rd when shaken If gas cylinder is empty you will not hear any sloshing of liquid 2 The gas valve is in the OFF position CONNECTING 1 Ensure valve is in OFF position 2 Check for any damage to the cylin...

Страница 5: ...artment of the heater 3 TILE MODEL 1 Push in and turn the gas control to Low 2 The electronic ingintion should be ticking sparking 3 Continue to push the gas control in for about 30 seconds 4 Release...

Страница 6: ...appliance is in an open area andnot subject to a strong direct breeze Turn off and restart Burner will not stay lit Suspect thermocouple Repair or replace Suspect valve Repair or replace Wind exceedin...

Страница 7: ...ion Any enclosure in which the appliance is used shall comply with the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a...

Страница 8: ...75 kPa Consumption 13 5 MJ h Certificate AGA 8937 G Part Number CH200 Description Gasmate Portable Camping Heater 2 Tile Gas ULPG Injector 0 57mm Pressure 2 75 kPa Consumption 9 0 MJ h Certificate AG...