HOSE & REGULATOR SAFETY
The regulator and hose assembly supplied with the
heater are suitable for Propane Gas.
A gas regulator adjusted to have an outlet pressure
of 2.75kPa is supplied for connection to the
propane gas cylinder. The pressure regulator and
hose assembly supplied with the heater must be
used. Replacement pressure regulators and hose
assemblies must be those specified by the heater
manufacturer.
When connecting the hose and regulator assembly
to the gas cylinder, take care to avoid unnecessary
twisting of the flexible hose.
After the assembly has been secured, turn on the
gas and check for leaks by brushing a soap and
water solution over all connections.
If you are unable to correct the leak by tightening
the connections, turn off the gas and contact the
supplier immediately.
Always ensure the heater is kept away from
flammable materials and the gas cylinder clear of
any heat source.
When changing over from an empty gas cylinder to
a full one make sure this procedure is carried out in
a well ventilated location, preferably outside, away
from people and away from any sources of ignition;
such as naked flames, pilot flames, electric heaters/
equipment.
GAS CYLINDER USE & SAFETY
This is a low pressure portable camping heater
and must only be used with the regulator supplied.
Your heater is designed for use with 4.5Kg or 9Kg
propane gas cylinders certified to AS 2469.
The gas cylinder should be filled by a reputable gas
supplier and visually inspected and requalified at
each filling.
Always keep cylinder in an upright position.
Always close the cylinder valve when the barbecue
is not in use.
Do not subject gas cylinder to excessive heat.
NEVER STORE YOUR GAS CYLINDER INDOORS.
If you store your heater indoors, ALWAYS
disconnect the gas cylinder first and store the
cylinder safely outside.
Cylinders must be stored outdoors in a well
ventilated area out of reach of children, and must
not be stored in a building, garage or any other
enclosed area.
Check the cylinder collar to ensure the test date
status is current (10 years from date stamp).
GAS INSTALLATION CODES
• Heaters must be used in accordance with the
installation requirements of your gas supply
authority, or the Australian Standard AS/NZS
5601.
• Heater is for use with bottled gas are labelled
‘Propane Gas’ or ‘ULPG’.
• Check the gas type sticker attached to the
heater.
CLEARANCES
Minimum Clearances from combustible materials
must be:
Rear - 200mm
Sides - 200mm
Above - 500mm
SPECIFICATIONS
Heater specifications can be found on the data label
attached to the heater body.
Hose connection thread is 1/4” BSP.
Maximum Hose Length is 1500mm
CARE & MAINTENANCE
Only use the regulator assembly supplied with the
appliance for direct connection to the cylinder.
DO NOT USE ADAPTORS.
DO NOT operate or store the appliance outdoors
when raining. If exposed to rain tilt the appliance to
allow any water ingress to escape.
IMPORTANT
Ensure the appliance is set up on a level
ground.
Never block or cover any of the ventilation
holes, air inlet or air outlet. If any of these are
cover poisonous CO and CO2 may built up to
a hazardous level and may cause death.
Do not move the appliance while in use or
when hot.
Before connecting and disconnecting to gas
source, make sure burner control is in OFF
position.
CAUTION: When the appliance is not in use,
the gas must be turned off at the cylinder or
the cartridge is disconnected.
Accessible parts may become hot. Keep
young children away!