background image

2

3

Installation, Operation and Maintenance Instructions

Prior to assembling your appliance, the following must be 
reviewed. Compliance with the following should result in 
satisfactory appliance operation. This instruction manual  
should be retained for future reference. The installation 
must conform with local codes or authority having jurisdiction.

1.  The appliance is intended for residential and non- 

residential outdoor spaces. The installation must conform 
with New Zealand Standard 5601 “Gas Installations”.

2.  Adequate clearance around air openings into the 
 

combustion chamber, clearances from combustible 

 

 

 

materials, provisions for accessibility and for 

   

 

 

combustion and ventilating air supply must be 

   

 

 

maintained at all times when the appliance is operating.

INSTALLATION

3.  Proper clearance from combustible materials must be    
 

maintained at all times. The minimum clearances are    

 

as follows:

 

Minimum Clearance from Combustibles:
Sides
  

650 mm 

 

Ceiling   800 mm    

Rear 

 

650 mm

Combustible materials are considered to be wood,   
compressed paper, plant fibres, plastic, plexiglas or 
other materials capable of being ignited and burned. 
Such materials shall be considered combustible even 
though flame proofed, fire-retardant treated or plastered. 
Additional clearance may be required for glass, painted 
surfaces and other materials which may be damaged by 
radiant or convection heat.

4.  The appliance must be placed on a level and adequate
 

footing and be readily accessible.

5.  The gas manifold supply pressure must be regulated 
 

at 2.75 kPa utilising an approved regulator 

 

 

 

(supplied with appliance).

6.  The appliance must be inspected before each use, and     
 

at least annually by a qualified service person.

 

a.   The appliance area must be kept clear and free of    

 

    combustible materials, gasoline and other flammable 

 

    vapours and liquids.

 

b.   Gas orifices and burner must be kept clear of dirt 

and cobwebs. Flow of combustion and ventilation air 
through the perforated portions of the appliance must 
not be obstructed. Cleaning with a soft brush before 
use and at least every six months is recommended.

 

c.  All gas connections should be checked for leaks 

utilising a soap solution. Never use a flame for this 
purpose.

 

d.  The flame pattern at the burner should be visually 

checked whenever the appliance is operated. 

 

    If flames extend beyond surface of the burner or 

 

    black soot is accumulating on the burner or reflector,

 

 

 

    the appliance should be turned off immediately.

   

 

 

    The appliance should not be operated again until the

 

    unit is serviced and or repaired.

Important Safety Rules:

This appliance must only be used in a well ventilated 
area.

1.  This appliance shall not be installed or used indoors, in 
 

buildings, garages or any other enclosed area.

2. DO NOT place articles on or against this appliance.

3. DO NOT use or store flammable materials near 
 

this appliance.

4. Children and adults should be alerted to the hazards of 

 

 

high surface temperatures, burns and clothing ignition.

5.  Children should be carefully supervised when they  
 

are in the area of the appliance.

6.

NEVER

 hang anything including clothes or other 

 

flammable items on the appliance.

7.

DO NOT

 operate this appliance unless it is fully 

 

assembled with glass tube, guards and reflector

8.  

DO NOT SPRAY AEROSOLS IN THE VICINITY 

  OF THIS APPLIANCE WHILE IT IS IN 

   

  OPERATION.

9.  Installation and repair should be done by a qualified 
 

service person. The appliance must be inspected 

 

before use and at least annually by a qualified service 

 

person. More frequent cleaning may be required as 

 

 

necessary. It is imperative that control compartment, 

 

burners and circulating air passages of the appliance 

 

and light be kept clean.

in place.

 

g.  The ceramic burner does not require cleaning and 

should NEVER be painted. The reflector may be  
cleaned, but never painted.  

 

e.  Any cleaning agent used on the appliance should be

of a non-combustible and non-corrosive nature.
Warm soapy water is ideal. While washing the 
appliance, be sure to keep the area around the burner 
and pilot assembly dry at all times. If the gas control 
is exposed to water in any way, do NOT try to use it. 
The appliance should be regularly cleaned and 
protected to reduce oxidation, ideally a cover should 
be used when not in use.

 

f.   Carbon deposits may create a fire hazard. Clean 

reflector and glass tube inside with soapy water if any 
carbon deposits develop. Always be very careful when 
cleaning the glass tube.

Содержание Blaze

Страница 1: ... Important The installer or seller must leave these instructions with the consumer IMPORTANT Retain these instructions for future use 4782 07 17 FOR OUTDOOR USE ONLY OPERATES ON LPG ULPG The glass tube will be extremely hot when it is working so never try to touch it and keep children away Turn off the appliance immediately if it starts raining and never use it while it is raining as the glass tub...

Страница 2: ...ons should be checked for leaks utilising a soap solution Never use a flame for this purpose d The flame pattern at the burner should be visually checked whenever the appliance is operated If flames extend beyond surface of the burner or black soot is accumulating on the burner or reflector the appliance should be turned off immediately The appliance should not be operated again until the unit is ...

Страница 3: ...PG ULPG Consumption 40 0 MJ h Operating Pressure 2 75 kPa Injector Size 1 95 mm Any modification to the appliance not described in the installation instructions may compromise the safety of this appliance Special concern is as follows 1 DO NOT bypass thermocouple safety burner 2 DO NOT operate appliance without the guards Clothing or other flammable materials should not be hung from the appliance ...

Страница 4: ...earance from Combustible Surfaces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned 650mm 800mm 1865mm Glass Tube 535mm Cylinder housing Burner head ...

Страница 5: ...ny damage to either the cylinder connection or the hose NEVER attempt to use damaged equipment 3 When connecting the hose to the cylinder tighten the nut to a positive stop by hand 4 Open cylinder valve fully If a leak can be heard at either end of the hose turn cylinder off and tighten joint Wait 5 minutes before re testing and use a soapy water solution to check the joint If bubbles appear the c...

Страница 6: ...ng 1 C Burner 1 D Cylinder Housing 1 E Glass Tube 1 No Part Name Qty F Mesh Guard 3 G Body Support 1 H Battery AA 1 I Upper Support 3 J Wheel Assembly 1 AA M5x12 Screw x 2PCS BB M6x12 Screw x 10PCS CC M8x16 Screw x 3PCS DD M6 Lock Nut x 10PCS GG Wrench x 1PC HARDWARE ...

Страница 7: ...ed M5 screws from the upper support I then slide the 3 upper support into the slots at the top of the burner C Once fully inserted secure the upper support I into the burner C by replacing the M5 screws that were removed at the beginning of this step Note Be sure that the hooks on the upper supports I are facing upwards Step 4 Align the holes at the bottom of the burner C to the top of the cylinde...

Страница 8: ...ten Step 6 Place the glass tube E into the top of the glass tube ring B Step 7 Remove the 3 preassembled screws from the upper supports I Place the upper reflector A onto the top of the upper supports I Replace the 3 screws removed at the beginning of this step to secure the upper combination A to the upper supports I Be sure to fully tighten Step 8 Attach the 3 mesh guards F onto the hooks at the...

Страница 9: ...BLY INSTRUCTIONS STEP 11 Ensure cylinder valve is in its full off position Check for any damage to either the cylinder connection or the hose NEVER attempt to use damaged equipment Attach the regulator and hose to your gas cylinder Tighten the nut to a positive stop by hand STEP 12 Turn on the gas cylinder ensuring that the control knob on the outdoor heater is turned OFF at this point DO NOT ATTE...

Страница 10: ...ob not ON Pilot light assembly bent or not in correct location LPG cylinder is near empty Turn knob to ON Contact service agent Warning White smoke may appear round the burner head during the first minutes of initial firing 1 Check and ensure that an AA battery is inside the ignition chamber and has power Ensure the anode faces outside 2 Ensure that the control knob is OFF Slowly open the gas cyli...

Страница 11: ...ls on all sides but at least one permanent opening at ground level and no overhead cover see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at least 30 of the remaining ...

Страница 12: ...12 ...

Отзывы: