3. The power socket shall be accessible to users (such as next to the cabinet) for
easy power-off.
4. After installation is complete, make sure that the power plug is firmly inserted
into the socket.
5. Please refer to the "Cabinet Diagram" for the requirements of net depth of the
cabinet. The clearance between the cabinet bottom board and the rear board
(or wall) shall not be less than 1.97 Inch.
White or Gray wire
Green wire
3-WIRE BRANCH CIRCUIT (for US only)
Refer to Figure A, where local codes allow the connection of GROUND wire from
the oven to the branch circuit NEUTRAL wire (gray or white colored wire):
●
lf local codes permit, connect the green GROUND wirefrom the oven to the
branch circuit NEUTRAL wire (gray or white colored wire).
●
Connect the red and black leads from the oven to the corresponding leads in the
junction box.
4-WIRE BRANCH CIRCUIT (for US and CANADA)
Refer to Figure B:
●
Disconnect ground from neutral at free end of conduit.
●
Connect the green GROUND wire from the oven to the GROUND wire in the
junction box (bare or green colored wire).
●
Connect the red and black leads from the oven to the corresponding leads in the
junction box.
www.gaslandchef.com
8350 Patriot Blvd STE B, N. Charleston, SC 29418
07
1 (844) 538-7890
Содержание ES606MS
Страница 2: ......
Страница 21: ...www gaslandchef com 1 844 538 7890...