MGC Pump 

8VHUV

 Manual

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MGC Pump

Страница 1: ...MGC Pump 8VHU V Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...arm Behavior Detector MaintenanceǤǤ Pump Testing Filter Replacement Applying Gas from a Gas Cylinder Bump Testing Manual Bump Test Instructions Calibration Manual Calibration Instructions Battery Instrument Options MenusǤ ͳͲ Main Menu ϭϬ Status Menu 1 Options Menu 1 Adjustable Options 1 Instrument Records Logs ǤǤ 1 Event Log 1 Bump Log 1 Calibration Log 1 Data Logs 1 Failures FAQ sǤ 1Ͷ Instrument ...

Страница 3: ...ur compounds phosphorus halogenated hydrocarbons and aerosols If suspected combustible sensor poisoning has occurred recheck the instrument both calibrate and bump test The detector should be bump tested before use with a known concentration of methane to confirm its ability to respond to gas Calibrate the detector if the readings are not within the specified limits Le détecteur doit être testé av...

Страница 4: ... Description Entry Description 1 Alarm bar LEDs 8 Model and Serial Label 2 Maintenance LED 9 Gas Exhaust 3 Alligator Clip 10 Charging Port 4 Infrared IR Port 11 Button 5 Gas Inlet 12 Audible Port 6 Filter Window 13 Display 7 Certification Label www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 5: ... for activation the detector will display LOW BAT and then turn off again Once activated the unit will begin to display gas readings immediately Each sensor will show a chasing O for the sensor reading while it is stabilizing and being self tested Chasing O Fully operational Once all sensors have completed the warm up sequence the detector is ready to detect all gases Turning Off the Detector Pres...

Страница 6: ...alibration or bump test the calibration bottle will be displayed when it is time to apply gas The battery is displayed in 3 bars as well as a percentage The percentage calculation is approximate and can be used to provide a rough estimation of the time remaining Warning Users must familiarize themselves with the icons in both non alarm and alarm states Warning If the display is missing icons or ca...

Страница 7: ...ble Alarm Vibration Alarm Visual Alarm Low Slow sweep Slow vibration Slow LED Ilash High Fast sweep Fast vibration Fast LED Ilash TWA Slow sweep Slow vibration Slow LED Ilash STEL Fast sweep Fast vibration Fast LED Ilash Multi Slow Fast sweep Slow Fast vibration Slow Fast Ilash Pump Blocked Fast sweep Fast vibration Fast LED Ilash Sensor Error Fast sweep Fast vibration Fast LED Ilash Low Battery 2...

Страница 8: ...nd the pump will enter into a pump blocked alarm Looking at the filter window will typically indicate a clean white or dirty dark color condition If the filters require replacement then remove the gas inlet by loosening the two screws Replace the hydrophobic and or particulate filters as required then reassemble to continue operating the detector 1 2 3 Applying Gas from a Gas Cylinder The detector...

Страница 9: ...l operation in alarm and the bump due date will be reset If a bump test interval has not been programmed into the unit users may simply apply gas to the instrument during normal operation However this will not be recognized as a bump test by the detector and therefore it will be recorded into the event log as an event Calibration 7KH detector can be configured to keep track of regular calibration ...

Страница 10: ... a rough estimation of the time remaining When the detector determines that only 20 minutes of run time remains it will beep flash and display LOW BAT on the screen This will repeat with 10 minutes remaining and then continuously for the last 5 minutes of run time When the battery has expired the detector will give 5 long beeps and flashes display OFF and then shut down To charge the detector conn...

Страница 11: ...unicated with via IR Link or 0 3XPS Dock User Message If the message is empty the detector will skip ahead If the startup message does not fit on one screen it will scroll right to left twice Sub Menu Prompts Pressing the button during a sub menu prompt will cause the detector to show more information If the button is not pressed the detector will immediately return to normal operation Status Menu...

Страница 12: ...m The self test lock option specifies whether a button press can silence the alarm Maintenance Notification If maintenance notification is enabled the detector will periodically flash the maintenance LED Otherwise if the option is disabled the detector will only show the maintenance text on the display Pump Test Will require the pump to be tested block and unblock on startup Dock Lock Dock Lock pr...

Страница 13: ... concentrations can be adjusted to match the respective levels contained within the gas bottle Default is 25ppm H2S 100ppm CO 18 O2 and 50 LEL 2 5 vol CH4 Language The detector will display all of its text prompts in any of WKH IROORZLQJ ODQJXDJHV English German French Spanish Italian or Portuguese Note OL Err and sensor icons remain the same for all languages XPS QWHUYDO 7KH EXPS LQWHUYDO FRQWURO...

Страница 14: ...e the first event and so on Bump tests are differentiated from normal events when the alarm condition occurs inside of WKH 0 3XPS Dock or when the instrument is manually bump tested according to the Manual Bump Test Instructions The detector records the bump status for each test x Date and time of bump test x Whether the test was performed manually or in an MGC Pump Dock x Each sensor s peak alarm...

Страница 15: ...his sensor is Under the 1egative Limit Try zeroing the sensor If it continues to display UL contact GCT for either warranty replacement or replacement sensor s BUMP DUE If the detector is displaying BUMP DUE the detector is either due for a bump test because of a scheduled test or has failed its last bump test Refer to the Bump Testing section for more details CAL DUE If the detector is displaying...

Страница 16: ...gle plug in electrochemical cell Combustible Plug in Infrared IR or 3HOOLVWRU User Options User Message Language Low Alarm High Alarm STEL Alarm TWA Alarm TWA Method TWA Interval STEL Interval SAFE Maintenance Notification Self test Lock Dock Lock Pump Test Sensor nable Calibration Interval Bump Interval Calibration Gas Approvals CSA IECEx pending ATEX pending INMETRO Class 1 Division 1 Group A B ...

Страница 17: ...nformation Gas Clip Technologies Inc 610 Uptown Blvd Suite 4100 Cedar Hill TX 75104 Toll Free 877 525 0808 Phone 972 775 7577 Fax 972 775 2483 E mail info gascliptech com Website www gascliptech com www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 18: ...roper storage installation calibration use maintenance and compliance with the user s manual instructions and any other applicable recommendations of GCT 2 The buyer promptly notifying GCT of any defect and if required promptly making the product available for correction No goods shall be returned to GCT until receipt by the buyer of instructions from GCT 3 The right of GCT to require that the buy...