Garrison 2498547 Скачать руководство пользователя страница 14

  Clogged filters reduce cooling, heating, and airflow

becomes torn or damaged, it should be replaced

, reinstall the four

reduce cooling, heating, airflow and efficiency of unit.

operate unit without filters in place. If a filter

  of the unit from the wall sleeve. Clean the vent filter

- If the vent door is open, access requires the removal

  professionally cleaned. Clean inside and outside of

  If clogged with dirt and soot, coil should be 

. Unit will need to be removed to inspect

  and abrasives. Some commercial cleaners may

. T

13

 CARE AND CLEANING

FRONT PANEL AND CASE

- Turn unit off and disconnect power supply o clean,
  use water and a mild detergent.

DO NOT 

use bleach

  damage the plastic parts.

- Removing Air Filter

Fig.9

OUTDOOR COIL

- Coil on outdoor side of unit should be checked 
  regularly
  dirt buildup on the inside of the coil.

  outdoor coils regularly.
  

NOTE:

 Never use a high-pressure spray on coil.

!

CAUTION

Failure to follow this caution may result in 
equipment damage or improper operation.
Airflow restriction may cause damage to the unit.

UNIT DAMAGE HAZARD

AIR FILTERS

IMPORTANT:TURN UNIT OFF BEFORE 

CLEANING.

- The most important thing you can do to maintain
  unit efficiency is to clean the filters once every
  two weeks as required.

.

!

CAUTION

Failure to follow this caution may result in 
equipment damge or improper operation.

Do not 

immediately.
Operating without filters in place or with damaged
filter will allow dirt and dust to reach indoor coil and

Airflow restriction may cause damage to unit.

UNIT DAMAGE HAZARD

Keeping filters clean will:

  Decrease cost of operation.
  Save energy.
  Prevent clogged indoor coil.
  Reduce risk of premature component failure.

To Clean Air Filters:

  Vacuum heavy soil. 
  Run water through filter.
  Dry thoroughly before replacing.

Pull up

2 Air filters

- Replacing  Air Filter

Fig.10

Push down

VENT DOOR FILTER

IMPORTANT:TURN UNIT OFF BEFORE 

CLEANING.

  twice a year or as required.
- Make sure to remove the shipping screw from the 
  vent door.(See.Fig.5)
- Rotate the vent control lever to open the vent door.
  (See. Fig.6)
- Remove four screws from the vent door filter.
   (See.Fig.11)
- First pull out the vent door steel wire from the hole 
  of the vent door, then take off the vent door and filter.
  (See.Fig.11)
- Clean the filter. Dry thoroughly before replacing.
- Replac the vent door and filter
  screws.
- Replace the vent door steel wire into the hole of the 
  vent door.

  
.

Vent door 
control lever

Vent door 
steel wire

Vent door 
filter

Screws

Fig.11

Vent door 

Содержание 2498547

Страница 1: ...PUMP Before using your air conditioner please read this manual carefully and keep it for future reference Model 2498546 2498547 2498548 2498549 2498550 2498551 2498552 2498553 2498554 2498555 2498556...

Страница 2: ...involved Children shall not play with the appliance Cleaning and user maintenance shall notbe made by children without supervision applicable for European countries This appliance is not intended for...

Страница 3: ...e fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause machine failure or electric shock It may cause fire and...

Страница 4: ...etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the pow...

Страница 5: ...thin the air conditioner The appliance shall be installed in accordance with national wiring regulations Do not use an extension cord or an adapter plug WARNING For Your Safety Do not store or use gas...

Страница 6: ...lug head on some products NOTES Do not use this device to turn the unit on or off Always make sure the RESET button is pushed in for correct operation The power supply must be replaced if it fails to...

Страница 7: ...ure 2 There is a 3 minute minimum compressor runtime at any setting to prevent short cycling The indoor fan motors starts before the compressor and stops after the compressor cycles off 3 Push S1 on t...

Страница 8: ...e unit displays LC pads on the control panel are not available The unit can be set with a wire controller only You can install the accessory on the control panel NOTE For some models there is a corres...

Страница 9: ...20 C 24 C Two configurations S4 S5 combine to select set point range S6 S7 Fan Continuous Run for Heating Fan Cycle for Heating Fan Continuous Run for Cooling Fan Cycle for Cooling Electric Heat Only...

Страница 10: ...the dip switch to the DOWN OFF position as shown below Insert the wire connector of the wall t into the relevant terminal according to different shapes as shown below hermostat Terminal of some types...

Страница 11: ...High fan is desired wire the G output from the themostat to HI FAN on the unit s terminal block The range of set temperature of must match the range of DIP switch setting must be set to match the uni...

Страница 12: ...and exhaust airflow See Fig 2 CAUTION There are sharp edges that can cause serious cuts When lifting the air conditioner VY people to lift COOLED AIR INTAKE AIR WALL WALL HEAT RADIATION SLEEVE Over 2...

Страница 13: ...with 4 screws and washers supplied in the SLEEVE ASSEMBLY through the unit flange holes See Fig 7 and Fig 8 Fig 7 Fig 8 1 2 Fig 9 Place tabs over top rail Push Inward at bottom until panel snaps into...

Страница 14: ...t thing you can do to maintain unit efficiency is to clean the filters once every two weeks as required CAUTION Failure to follow this caution may result in equipment damge or improper operation Do no...

Страница 15: ...f F UNIT MAKING NOISES Clicking gurgling and whooshing noises are normal during operation of unit WATER DRIPPING OUTSIDE If a drain kit has not been installed condensation runoff during very hot and h...

Страница 16: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...