background image

Magnum P80F & P80C Personal Switches                      Installation and User Guide (07/03)

 

 

 

 

16 

www  GarrettCom  com

.

.

1.    Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into 
 

the RJ-45 connector of the port. Note that, even though the connector is shielded, either 

 

unshielded or shielded cables and wiring may be used.  

2.   Connect the other end of the cable to the corresponding device. 
3.   Use the LINK LED to ensure proper connectivity by noting that the LED will be 

illuminated when the unit is powered and proper connection is established. If this does 
not help, ensure that the cable is connected properly and that the device on the other end 
is powered and is not defective.  

4.   For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a  

cross-over or up-link for linking to another hub or Switch. 

3.2.2  Connecting Fiber Optic ST-type, “twist-lock”

 

 

 

 

The following procedure applies to installations using ST-type fiber connectors. This 

procedure applies to ports using multi-mode ST fiber connectors. 

1. 

Before connecting the fiber optic cable, remove the protective dust caps from the  tips of 

 

the fiber connectors.  Save these dust caps for future use. 

2. 

Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue 
dampened in alcohol.  Make certain the connectors are clean before connecting.

 

Note: 

One strand of the duplex fiber optic cable is coded using color bands at 

regular intervals; you must use the color-coded strand on the associated ports at 
each end of the fiber optic segment
.

 

3. 

Connect the Transmit (TX) port (light colored post) on the Magnum Fiber port to the 
Receive (RX) port of the remote device.  Begin with the color-coded strand of the cable 
for this first TX-to-RX connection. 

4. 

Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the 
remote device. Use the non-color coded fiber strand for this. 

5.  The LINK LED on the front of the fiber connector will illuminate when a proper 

connection has been established at both ends (and when power is ON in the 
unit). If LINK is not lit after cable connection, the normal cause is improper 
cable polarity.  Swap the fiber cables at the fiber connector to remedy this 
situation. 

3.2.3  Connecting Fiber Optic SC-type, "Snap-In"

 

   

The following procedure applies to installations using SC-type fiber connectors, i.e., 

using multi-mode SC and SC single-mode. 

   

When connecting fiber media to SC connectors, simply snap on the two square male 

connectors into the SC female jacks of the Fiber connector until it clicks and secures.

 

3.2.4 Connecting 

Single-Mode Fiber Optic 

When using single-mode fiber cable, be sure to use single-mode fiber port connectors.  

Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for 

single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the 

core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at 

longer distances, about 20Km with the multi-mode SC.

 

Содержание Magnum P80F-MSC-d

Страница 1: ...www GarrettCom com Magnum P80F P80C Personal Switches Installation and User Guide 5 00 USD...

Страница 2: ...witch are trademarks and Personal Switch is a registered trademark of GarrettCom Inc Important The Magnum P80F P80C Personal Switch contains no user serviceable parts Attempted service by unauthorized...

Страница 3: ...diate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and fou...

Страница 4: ...r ports can be connected in strings Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing Dual Speed 8 port and 16 port Stackables 10 100 auto sensing Stackable Hubs SNMP Optional 10Mb series an...

Страница 5: ...onnecting Fiber Optic ST Type Snap In 16 3 2 4 Connecting Fiber Optic Single mode 16 3 2 5 Power budget Calculation for P80F Fiber media 17 3 2 6 Connecting to NICs which support Auto Negotiation 17 3...

Страница 6: ...Latency not including packet time 100 to 10 Mbps 5 s 10 to 100Mbps 5 s Path Delay Value 50 BT on all ports Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft 100...

Страница 7: ...r Half Duplex selection on switched Ports 2 or 2SW for Magnum P80F Manual switch selects fiber port for FDX or HDX See Section 4 3 for details Full Fixed or Auto negotiation selection on switched Port...

Страница 8: ...Magnum P80F SSC d or i Same as P80F but with single mode SC type fiber connector Magnum P80F SSCL d or i Same as P80F but with single mode Long reach 40Km SC type fiber connector Magnum P80F MTRJ d or...

Страница 9: ...o keep the shipping container should you need to ship the unit at a later date To validate the product warranty please complete and return the enclosed Product Registration Card to GarrettCom as soon...

Страница 10: ...services to network changes and expansions Top mounted LEDs provide status information on each port The Magnum P80 P80F Personal Switches provide high performance plug and play operation in compact pa...

Страница 11: ...on capability See section 4 4 LEDs to indicate operating status of all ports are mounted on the top There are power PWR and ERROR self test at power up failed indicators for the unit For each port the...

Страница 12: ...iber port is a switched port and performs as a domain providing a high bandwidth backbone connection no media converter is required and supporting long up to 40km fiber cable distances for installatio...

Страница 13: ...peration is that more bandwidth is available for good packets when the traffic load is greatest To minimize the possibility of dropping frames on congested ports each Magnum P80 P80F Personal Switches...

Страница 14: ...nds plus the packet time at 10 Mb For 100Mb to 100Mb forwarding the latency is 5 microseconds plus the packet time at 100Mb 2 6 Features and Benefits 100Mb switching services for high performance Ethe...

Страница 15: ...rkspace location within reach of a standard AC wall outlet They come in a durable metal enclosure for table top or wall mount There is a choice of external power supplies for either 115vac or 230vac 2...

Страница 16: ...than needing an auxiliary media converter unit The 100Mbps traffic does not use the bandwidth of the 10 Mbps domain so overall performance of the network is sustained at the highest possible level Exa...

Страница 17: ...ility devices such as print servers run at 10 Mbps High performance users need a high bandwidth up link for access to a central LAN and central file servers Any attached node can change speed at any t...

Страница 18: ...0C site The rugged metal case of the Magnum P80F P80C will normally protect it from accidental damage in a lab or workplace setting Maintain an open view of the top surface to visually monitor the sta...

Страница 19: ...used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft For fiber port 100BASE FX multi mode 50 125 or 62 5 125 microns cabling can be used whereas for single...

Страница 20: ...d using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Mag...

Страница 21: ...to network designers and installers Fiber Port Module Speed Std Mode Std km fdx hdx Wave length nm Cable Size m X mitr Output PT dB R cvr Sens PR dB Worst OPB dB Worst distance Km fdx typical OPB dB t...

Страница 22: ...th each unit The small DC power cord from the power supply plugs into the matching rear power jack of the P80F and P80C Personal switchess When the power is applied the green PWR LED will illuminate E...

Страница 23: ...iguration settings are user options for UP LINK on RJ 45 port 1 Half Full duplex mode selection for the switched fiber port and FF AN can be done through a switch accessed from the front of the unit f...

Страница 24: ...ps speed When the LINK ACT LED is ON steady ON indicates LINK with no traffic blinking ON indicates the port is transmitting receiving The port has auto negotiated for operation If a P80F or P80C RJ 4...

Страница 25: ...Cascaded connections may be operated at either 10 or 100Mbps speed The P80F even supports cascaded connections of both 10 Mbps and 100Mbps at the same time on different ports When attaching a 10 Mbps...

Страница 26: ...llation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have...

Страница 27: ...rence of the problem Any changes to system administration procedures should all be noted in this record 5 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a...

Страница 28: ...hipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY...