GarrettCom Magnum P62F Series Скачать руководство пользователя страница 24

Magnum P62F-Series Ethernet Switches                         Installation and User Guide (11/01)

18

www  GarrettCom  com

.

.

3.2.6

Connections to NICs which support Auto-Negotiation, RJ-45 ports

The copper ports of Magnum P62F-Series Ethernet Switches will function properly

with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse

(FLP) coding for the 100BASE-TX signaling system.  When connecting a NIC to a P62F, it may

be necessary to reload the NIC drivers on the user device if the NIC has been communicating

with a protocol other than 100BASE-TX (such as 10BASE-T).  When 100Mb speed is agreed

and in use, the 10/100 LED is steady ON.  It is OFF if there is no traffic or if 10 Mbps traffic.

3.3 

 

Powering the Magnum P62F-Series

3.3.1

Powering the P62F models, for –48V and 24V DC power input

Each

 

Magnum Model P62F Ethernet Switch requires a DC power source, from 20-

70VDC. The wide range of power input qualifies this product for use both in 24VDC as well as -
48VDC environments. The 24VDC or -48VDC power input provides an Ethernet networking
product utilizing a special type of power supply with a proven high-reliability record.

DC Power Terminals

: “+”, “

-

,

internally floating

GND

:  Terminal for “earth” or ground wire

connection to the P62F chassis

Input Voltage

: 20 to 70 VDC

Input current

: 0.7 amp max.

Power Consumption

: 10 watts typical

P62F  -48V, 24VDC  INSTALLATION

This section describes the proper

connection of the -48VDC leads (or 24VDC
leads) to the DC power terminal block on
the Magnum P62F Switch (as shown in
Figure above)
The DC terminal block on the Magnum P62F Switch is located on the left front of the unit and is
equipped with three (3) screw-down lead posts. The power terminals are identified as positive
(+) and negative (-), and they are floating inside the unit so that either may be grounded by the
user if desired.  The chassis is “earth” or ground (GND).

The connection procedure is straightforward. Simply insert the DC leads to the

Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is
optional; it connects to the Switch chassis. Ensure that each lead is securely tightened.

NOTE:

Always use a voltmeter to measure the voltage of the incoming power supply and

figure out the +ve potential lead or -ve potential lead. The more +ve potential lead will
connect to the post labeled “+ve” and the rest to the “-ve”.
The GND can be hooked up at the last.

When power is applied, the green PWR LED will illuminate.

Содержание Magnum P62F Series

Страница 1: ...ttCom com www GarrettCom com Corporate Headquarters GarrettCom Inc 213 Hammond Avenue Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Web www GarrettCom com Email support Garrettcom com Magnum P6...

Страница 2: ......

Страница 3: ...witch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum P62F Series Ethernet Switches contains no user serviceable parts Attempted service by unauthorize...

Страница 4: ...ate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found...

Страница 5: ...d Media Fiber Hub 16 port Stackable 10 100 auto sensing Dual Speed 8 port and 16 port Stackables 10 100 auto sensing Stackable Hubs SNMP Optional 10Mb series and 100Mb series both with optional port m...

Страница 6: ......

Страница 7: ...de 16 3 2 5 Power budget Calculation for P62F Fiber media 17 3 2 6 Connecting to NICs which support Auto Negotiation 18 3 3 Powering the Magnum P62F Series Switches 18 3 3 1 Powering the Magnum P62F 4...

Страница 8: ...not including packet time 100 to 10 Mbps 5 s 10 to 100Mbps 5 s Path Delay Value 50 BT on all ports Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft 100BASE TX C...

Страница 9: ...plate included Suitable for stand alone shelf pedestal or wall mounting The case also serves as a heat sink The metal mounting base is included 13 guage steel Without the base the box size is only 7...

Страница 10: ...45 and no fiber ports Has 16KB address table and 1 0MB packet buffers AC power input 85 260vac 47 63Hz worldwide auto ranging via PSX A Power Source Extended Temp a separate unit Steel case used as a...

Страница 11: ...agnum P62F 5V NOF Same as P62F NOF except with 5VFC input via PSX A using military type screw lock connectors Magnum PSX 5V CBL spare 2 ft power cord with military type screw lock connector spare for...

Страница 12: ...nstallation and User Guide 1 Product Registration Card Optional if AC power 1 PSX A Power Source Extended Temp unit 1 6 ft long AC Power chord for PSX A Unit only Optional PSX T 125 VDC 1 PSX T Power...

Страница 13: ...operate in temperature uncontrolled applications the P62F s high strength steel case functions as a heat sink to draw away the heat from the internal electronics and dissipate it The efficient design...

Страница 14: ...rs The fiber ports 1 and 8 have LK ACT indicators The rugged design of the case using high strength rugged 18 gauge steel enables this product to withstand environments with inhospitable high low temp...

Страница 15: ...dicates the port is transmitting receiving The 10 100 LED is ON for 100Mbps and OFF for 10 Mbps when LINK is made For fiber ports the LEDs are the same except no F H and 10Mb is not possible A device...

Страница 16: ...internally to provide maximum network performance with the least dropped packets When the P62F Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex on...

Страница 17: ...are on the top of the unit for easy viewing in any situation As the units are normally vertical for wall or pedestal mounting top surface viewing is most convenient Installation is Plug and Play opera...

Страница 18: ...Switch serves this requirement economically and efficiently The six full and half duplex switched ports make the required setup simple for collection of traffic data The uncontrolled outdoor temperatu...

Страница 19: ...the temperature controlled packaging to provide an exceptional Ethernet product Figure 2 6 2 Three P62F connects together to provide 10 Mbps and100Mbps network with Fast Ethernet backbone In this exam...

Страница 20: ...P62F unit Maintain an open view of the top surface to visually monitor the status LEDs 3 1 1 Table Top or Shelf Mounting The Magnum P62F Ethernet switch can be easily mounted on a table top shelf or a...

Страница 21: ...per wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode 100BASE FX SC Fiber Single mode 100BASE FX SC NOTE It is recommende...

Страница 22: ...of the duplex fiber optic cable may be coded using color bands at regular intervals you should use the color coded strand on the associated ports at each end of the fiber optic cable segment 3 Connec...

Страница 23: ...2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km The following data has been collected from component manufacturer s HP s and Siem...

Страница 24: ...igh reliability record DC Power Terminals internally floating GND Terminal for earth or ground wire connection to the P62F chassis Input Voltage 20 to 70 VDC Input current 0 7 amp max Power Consumptio...

Страница 25: ...to the P62F 5V Switch Input Voltage 85 264 VAC 47 63HZ Auto ranging AC Power Connector IEC type male recessed Power Output 5VDC 3Amps max Input Fuse for overload and short protection 3AG type 0 5 Amp...

Страница 26: ...ew down lead posts covered by a removable safety shield or cover The power terminals are identified as positive and negative and they are floating inside the unit so that either may be grounded by the...

Страница 27: ...ef feature provided as part of the package design The Magnum P62F Series Switches have a tie wrap holder as part of the base plate of the unit for use for cable strain relief The strain relief feature...

Страница 28: ...by auto negotiation to full or half duplex as the unit attached with these ports The internal functions of P62F is described below Switching Filtering and Forwarding Each time a packet arrives on one...

Страница 29: ...ides will agree to the speed being used Depending upon the device connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed When the LK ACT LED is ON steady ON indicates LI...

Страница 30: ...stallation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they h...

Страница 31: ...s workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any...

Страница 32: ...he unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shi...

Отзывы: