![GarrettCom Magnum P62-Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/garrettcom/magnum-p62-series/magnum-p62-series_installation-and-user-manual_567766009.webp)
Magnum P62-Series Hardened Switches Installation and User Guide (12/02)
5
www GarrettCom com
.
.
1.2
Ordering Information
Magnum P62-Series, 10/100 Ethernet Switch
Magnum P62F-AC-2MSC:
P62F-AC Ethernet Switch with six 10/100 RJ-45 and two
100Mb FDX fiber multi-mode SC-type ports. Has 16KB address table and 1.0 MB packet
buffers. AC power input, 85-160vac 47-63Hz worldwide auto-ranging via PSX-A power
source Extended Temp ( a separate unit). Steel case used as a heat sink, designed for use in
environmentally challenged locations such as “outdoors” with extended temperatures.
Magnum P62F-AC-1MISSC
: Same as P62F-AC-2MSC, except one fiber port is 20km
single-mode SC. (includes PSX-A unit)
Magnum P62F-AC-2SSC:
Same as P62F-AC-2MSC, except both fiber ports are 20km
single-mode SC. (includes PSX-A unit)
Magnum P62F-AC-NOF
:
P62F-DC Ethernet Switch, six 10/100 RJ-45 and no fiber
ports. Has 16KB address table and 1.0MB packet buffers. AC power input 85-
260vac 47-63Hz worldwide auto-ranging, via PSX-A Power Source Extended
Temp (a separate unit). Steel case used as a heat sink, designed for use in
environmentally auto-ranging. Steel case used as a heat sink, designed for use in
environmentally challenged locations
such as “outdoors” with extended temperatures
.
Magnum P62F-2MSC:
8-port Ethernet Switch with two 100Mbps full-duplex switched
fiber ports (multi-mode SC-type connector), and six half- or full-duplex switched
RJ-45 10/100 auto-negotiating ports. Includes store-and-forward switching that
filters and forwards data moving between the ports. The internal switch has 16K
nodes address table and 1MB packet buffers. DC power input, 18-70VDC auto-
ranging.
Steel case acts as a heat sink. Rated for extended temperature.
Magnum P62F-1M1SSC:
Same as P62F-2MSC, but with one multi-mode SC-type and
one 20Km single mode SC fiber connectors.
Magnum P62F-2SSC:
Same as P62F but with two 20Km sgl-mode SC-type fiber ports
Magnum P62F-
NOF:
P62F-DC Ethernet Switch, six 10/100 RJ-45 and no fiber ports.
Has 16KB address table and 1.0MB packet buffers. DC power input, 18-70VDC
auto-ranging. Steel case used as a heat sink, designed for use in environmentally
challenged locations
such as “outdoors” with extended temperatures.
Parts
Magnum P62F-5V-2MSC:
Same as P62F-2MSC, except with 5VDC input using
military-type-screw-lock connector.
Magnum P62F-5V-1M1SSC:
Same as P62F-1,1SSC, except with 5VDC input using
military-type-screw-lock connector.
Magnum P62F-5V-2SSC:
Same as P62F-2SSC, except with 5VDC input using
military-type-screw-lock connector.
Magnum P62F
-
5V-NOF: Same as P62F-NOF, except with 5VFC input via PSX-A
using military-type screw lock connectors.
Magnum PSX
-
5V-CBL (spare):
2-ft power cord with military type screw-lock
connector, spare for PSX to P62F-5V power cord.
Magnum PSX-A:
P62F
-
5V Power Source for Extended Temperature, nominal AC
input 115-240vac at 47-63HZ auto-ranging, 15 watts, 5VDC output at 3Amps.
Steel case used as a heat sink. Extended temperature rated. Output power cord
has military-style screw-lock plug. Mounts as a separate unit adjacent to a
Magnum Model P62F-5V Switch.
Magnum PSX-T:
Same as PSX-A , except 125VDC to 250VDC input, terminal lugs
for “+”, “-“, and GND