Magnum DS880 Dual-Speed Stackable Hubs                  Installation and User Guide (05/01)  

 

www   rrettCom  com

.

.

2.3 

Stacking Magnum DS880s 

Up to four Magnum DS880s can be stacked to operate as one 10/100 dual-speed 

repeater with up to 32 dual-speed ports.  Normally, one Magnum DS880-B hub per stack is 

needed to provide a 

switched interconnection 

between the two separate 

100Mb and 10Mb traffic 

domains in the stack.  

Additional stacked units 

are normally Model 

DS880-A “add-on” units, 

which cost less.   

OUT

IN

OUT

IN

OUT

IN

OUT

IN

 

FAN  EXHAUST

      

Figure 2.3 :  Magnum DS880’s stacked.  Cables connect between “Out” and “In” Ports  

The DS880-B models with the bridge module inside look the same as the DS880-A 

units (no bridge inside) from the outside.  The “BR” LED on the front will light up when power 

is applied to indicate that a DS880 is a -B (bridge inside) model.  (The “BR” LED will be off if 

the unit is a Model DS880-A).  The DS880-B models cannot be stacked together, as their 

internal bridges would not be able to function properly when more than one is present.  (Note 

that two DS880-B units may be cascaded to operate together, however). Use DS880-B models 

un-stacked, or with only 1 Model DS880-B in a DS880 stack.  See Section 2.7, Example 3. 

 

When stacking DS880’s,  please make sure to use only the shielded 9-inch long 

stacking cable provided with each DS880-A unit.  The cable length is designed to provide 

proper operation of up to four DS880 units in a stack, and longer cables or unshielded cables are 

not permitted as they will not operate properly at 100Mb speeds.  

The 9-inch length is enough to provide for side-by-side stacking. This can be 

convenient when locating the DS880s in a rack, for example, as two DS880s will fit side-by-side 

on a tray in a standard 19” rack space.   

When connecting DS880s in a stack, use the stacking cable to connect the “Out” 

stacking port from one DS880 unit to the “In” stacking port of the other.  Push in the cable 

connectors until they snap in firmly.  Also, leave space in the left-rear area for the exhaust of the 

internal cooling fan in each DS880 unit.  See Figure 2.3 above.

 

Ga

 

Содержание Magnum DS 880

Страница 1: ...www GarrettCom com Magnum DS 880 10 100 Dual Speed Stackable Hubs I n s t a l a Installation and User Guide 5 00 USD...

Страница 2: ...re trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum DS880 10 100 Dual Speed Stackable Hubs family contains no user serviceable parts Attempted service by un...

Страница 3: ...n radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and...

Страница 4: ...ber ports can be connected in strings Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing Dual Speed 8 port and 16 port Stackables 10 100 auto sensing Stackable Hubs SNMP Optional 10Mb series...

Страница 5: ...t Auto Negotiation 17 3 3 Powering the Magnum DS880 18 4 0 OPERATION 18 4 1 Dual Speed Functionality 18 4 1 1 Software Transparency 20 4 2 Port Speed settings for 10 100 and 10 100Mbps Mode only 20 4...

Страница 6: ...g for speed IEEE 802 3u Packet Processing Between Domains internal 10 100 switch or bridge Filtering and Forwarding Rate from 100Mb ports 148 800 pps max Filtering and Forwarding Rate from 10Mb ports...

Страница 7: ...ub The up link port 8 is auto sensing for speed and the up link works the same at 10Mb or 100Mb Packaging Enclosure High strength metal Metal mounting brackets included Suitable for wiring closet shel...

Страница 8: ...ing cable internal auto ranging power supply cooling fan and metal brackets for shelf or wall mounting Magnum DS880 B Same as Magnum DS880 A but includes an internal switch module that bridges the two...

Страница 9: ...ower Cord U S and other 115 vac locations only 1 Stacking Cable Model DS880 A add on no bridge inside units only 1 Set of metal clips and screws for wall mounting 1 Installation and User Guide 1 Produ...

Страница 10: ...CT PWR LK RX BR UPLINK 1 2 3 4 5 6 7 8 GARRETT PWR 1 2 3 4 5 6 7 8 Magnum 8000E Stackable Hub 9 10 11 12 Figure 2 2 1 Magnum DS880 is functionally both a 10Mb and a 100Mb hub in one As Magnum DS880 Du...

Страница 11: ...K RX BR 100 UPLINK 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 COL ACT 100 10 PWR LK RX BR 100 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 COL ACT 100 10 PWR LK RX BR 100 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 COL 100 10 RX ACT PWR...

Страница 12: ...g information The AC power cord connector a universal recessed male IEC type is in the left rear of the chassis The internal power supply is auto ranging for any AC power input of 115 230 vac 50 60 Hz...

Страница 13: ...eir internal bridges would not be able to function properly when more than one is present Note that two DS880 B units may be cascaded to operate together however Use DS880 B models un stacked or with...

Страница 14: ...learning so that filtering forwarding of 10Mb and of 100Mb packets is maintained correctly even when users move their connection or change speed or power down The DS880 B s bridge module is implement...

Страница 15: ...rformance switching provides full bandwidth in each domain unaffected by local traffic on the other domain One DS880 B per stack supports switching for all ports Stackable for flexible expansion Magnu...

Страница 16: ...evices Example 2 Where there are existing 10Mb hubs and users they can easily be cascaded into any port of the DS880 B This allows simple plug and play addition of 100Mb ports to an existing 10Mb netw...

Страница 17: ...ordingly Separately the 100Mb traffic domain obeys all of the rules of 100Mb Fast Ethernet shared networks hop counts PDVs cable types cable distances etc and can be treated as one 100Mb repeater Both...

Страница 18: ...stalling the Magnum DS880 hubs 3 1 Locating Magnum DS880 Dual Speed Hubs The location of a Magnum DS880 Dual Speed Hub is dependent on the physical layout of the network Typically the hub is placed wh...

Страница 19: ...cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 3 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 NOTE It is recommended that high quality CAT 5 cables which work for bo...

Страница 20: ...E Std 802 3u 1995 actual delays may be less for a particular cable Contact your cable supplier for exact cable specifications Each Fast Ethernet device component also has an associated BT delay which...

Страница 21: ...2 X 486 BT X 512 486 BT X 28 BT Twisted Pair cable length TL 28 BT 1 112 m BT TL 25 meters 25 m maximum total length for Category 5 inter repeater segment 1 2 3 4 5 6 7 8 COL ACT PWR LK RX BR UPLINK 1...

Страница 22: ...ue to the relatively shorter bit time 80 BT actually measured for front port to port delay of the 100Mbps domain of the Magnum DS880 vs the industry standard delay of 92 BT for Class II repeaters The...

Страница 23: ...rivers on the user device if the NIC has been communicating with a protocol other than 100BASE TX such as 10BASE T When 100Mb operation is agreed and in use the 100Mb LINK ACT LED is illuminated stead...

Страница 24: ...ade based on the destination address contained in each packet If the destination address is on the same domain from which the packet originated then it is filtered and not forwarded to the other domai...

Страница 25: ...and when a new node address will be added to the internal Address Table When a new node address packet comes into a port for the first time then the new source address is learned at the same time tha...

Страница 26: ...10 100Mbps or 10 100Mbps auto sense The unit has been set at 10 100Mbps at the time of shipping The Switch SW3 represents port 1 to 4 and the switch SW2 port 5 to 8 as shown in the Fig 4 2 above The s...

Страница 27: ...LED ON when a bridge module is present in the unit model DS880 B OFF when no bridge module is present model DS880 A COL Two collision LED s one for each traffic domain 10 and 100Mb Blinks intermitten...

Страница 28: ...ection of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been pro...

Страница 29: ...ng personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrenc...

Страница 30: ...it in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping...

Страница 31: ...power supply internally nor will it blow the fuse in the internal power supply A A GND GND CHASSIS FUSE SUPPLY HUB POWER SWITCH The power switch included on premium priced NEBS certified units only i...

Страница 32: ...the 48V or 48V power supply should be connected to the post leveled and then the rest Ensure that each lead is securely tightened 36 70VDC _ GND ON OFF On the premium priced NEBS compliant Magnum DS88...