Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)
NOTE:. When leaving 6KPM slots empty, always use a face plate (Magnum 6KM-
BLNK) to cover the slot opening in the front panel. This will maintain proper cooling
air flow, safety, and operation as required by FCC, CE, and other regulations.
Step 6.
Now screw down the daughter board with 7 #4-40 screws, except the last two at
the end, so that it holds the daughter board securely. The figure below shows the
top view of 6KPM card after successfully installing the 6KPM cards inside the
Magnum 6K32F.
Fig. 3.5.2e
Top View : 6KPM Module installed inside a 6K32F Series Switch
Step 7.
Once the 6KPM cards have been installed, the chassis top cover can be placed
by matching up the two front corners properly and sliding it in until it reaches
the rear end and fits properly to match the holes. Make sure the chassis cover is
aligned properly before securing the enclosure. Secure the cover with 18 #4-40
screws.
Step 8.
Once the installation of cover is done properly, the front panel screen
plates(included with the 6K-modules) need to be properly placed on the front of
the chassis cover to complete the installation process.
3.5.3
Removing 6KPM Cards
To properly remove a 6KPM card from the 6K32F Managed Switch, follow the
3 steps below.
Step 1. Remove chassis cover
See procedures in Section 3.5.1 above.
Caution: Be sure the power cord is unplugged.
40