background image

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

 

 

18

www  GarrettCom  com

.

.

standard and fulfills its role in support of QOS, giving packet processing priority to 

priority tagged packets according to the 802.1p standard.  In addition to hardware support 

for QOS, the MNS software (R2) supports two priority queues that can be shared across 

the eight levels of defined packet priorities for application-specific priority control by the 

user through software configuration settings. 

 

2.2.9 

Frame Buffering and Flow Control 

 

Magnum 6K16-Series’s are store-and-forward switches.  Each frame (or 

packet) is loaded into the Switch’s memory and inspected before forwarding can occur.  

This technique ensures that all forwarded frames are of a valid length and have the 

correct CRC, i.e., are good packets.  This eliminates the propagation of bad packets, 

enabling all of the available bandwidth to be used for valid information.  

 

While other switching technologies (such as "cut-through" or 

"express") impose minimal frame latency, they will also permit bad frames to propagate 

out to the Ethernet segments connected.  The "cut-through" technique permits collision 

fragment frames (which are a result of late collisions) to be forwarded which add to the 

network traffic.  Since there is no way to filter frames with a bad CRC (the entire frame 

must be present in order for CRC to be calculated), the result of indiscriminate cut-

through forwarding is greater traffic congestion, especially at peak activity.  Since 

collisions and bad packets are more likely when traffic is heavy, the result of store-and-

forward operation is that more bandwidth is available for good packets when the traffic 

load is greatest.  

When the Magnum 6K16-Series Switch detects that its free buffer queue space 

is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the 

devices sending packets to cause “flow control”. This tells the sending devices to 

temporarily stop sending traffic, which allows a traffic catch-up to occur without 

dropping packets.  Then, normal packet buffering and processing resumes. This flow-

control sequence occurs in a small fraction of a second and is transparent to an observer.  

Another feature implemented in Magnum 6K16-Series Switches is a collision-based 

flow-control mechanism (when operating at half-duplex only). When the Switch detects 

that its free buffer queue space is low, the Switch prevents more frames from entering by 

forcing a collision signal on all receiving half-duplex ports in order to stop incoming 

traffic.  

 

 

Содержание Magnum 6K16 Series

Страница 1: ...i www GarrettCom com Magnum 6K16 Series Managed Fiber Switch Hardware Installation and User Guide Magnum 6K16V mounted vertically Two 6K16s mounted side by side on Tray...

Страница 2: ...onal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6K16 Series Managed Fiber Switch contains no user serviceable parts Attempted service by un...

Страница 3: ...he manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications...

Страница 4: ...aged Network Software MNS 6K for Magnum 6K8 Series 19 2 3 Features and Benefits 20 2 4 Applications 21 3 0 Installation 25 3 1 Locating Magnum 6K16 Series Switches 25 3 2 Connecting Ethernet Media 25...

Страница 5: ...tor 48 5 2 4 6KP6 RJSSCL connector 49 5 2 4a 6KP6 RJ10ST connector 49 5 2 5 6KP8 MTRJ Small Form factor 50 5 2 5a 6KP6 MT10ST ST Fiber port 50 5 2 6 6KP8 45MT FX MTRJ Small Form Factor 51 5 2 7 6KP8 M...

Страница 6: ...c 5 2 10 11 10 05 minor updates as MDIX support added on all RJ 45 port modules 02 05 minor updates and tweaks on LC port module 07 04 6K16 carrier class managed switch has been added with 6K16V 01 04...

Страница 7: ...U UNITS 4K SERIES SWITCHES 100 AND 10 MBPS COPPER PORTS WITH OPTIONAL FIBER PORT WITH AUTO NEGOTIATING FULL SWITCHING PERFORMANCE QUAD SERIES FIBER SWITCHES 100 10MBPS FIBER AND COPPER PORTS MIXED SPE...

Страница 8: ...0MB SERIES ALL MEDIA COMBINATIONS INCL FIBER ST SC MM SINGLE MODE THE X LINE OF CONFIGURABLE MIXED MEDIA PRODUCTS STACKABLE CONCENTRATORS SNMP OPTIONAL 13 PORTS MINI CONCENTRATORS 7 PORTS REPEATERS 2...

Страница 9: ...Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2 km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast E...

Страница 10: ...formal Coating humidity protection option Request quote Alarm Relay Contacts One NC indicating internal power one NC software controllable Packaging Enclosure Rugged High strength sheet metal Dimensio...

Страница 11: ...l or DIN Rail mounting 6K16V Horizontal Rack mount 2 units side by side on 19 or 21 rack 6K16 Agency Approvals and Standard Compliance Magnum 6K16V UL listed UL60950 cUL CE Emissions meet FCC Part 15...

Страница 12: ...s 6KP8V SLC SFF Fiber module w eight 100Mbps sgl m FX LC connectors 6KP4V FXSC 2 2 100Mb Fiber module w four 100Mb 2km FX SC connectors 6KP4V FXST 2 2 100Mb Fiber module w four 100Mb 2km FX ST connect...

Страница 13: ...ept the power input is 125VDC Configuration Options Each Magnum 6K16 base unit has TWO port module slots Magnum 6K16 Port Modules 6KP8 MTRJ SFF Fiber module w eight 100Mb mm FX MT RJ connectors 6KP8 M...

Страница 14: ...TRAY to ETSI and or to 23 Telco rack Gigabit 1000Mb Transceivers option for Mangum 6K16 Series 6K16V 6K16 GBIC SXSC GBIC transceiver module for use in GBPM xOTX one 1000BASE SX port with mm SC fiber c...

Страница 15: ...ce and four 100 Mb 15km sm FX LC connectors New P6KP8 45 2MT 6 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two normal RJ 45 10 100 ports two100 Mb 2km mm FX MTRJ connectors New...

Страница 16: ...odule options installed 1 AC Power Cord U S and other 115 VAC only if AC version 1 Set of two metal vertical mounting brackets with screws to the case 1 Installation and User Guide this manual 1 Produ...

Страница 17: ...tandard GBIC ports can be configured for a variety of Gigabit cabling types and distances The 6K16 Series managed switches also provides PoE option via power inside PoE modules on one of A or B slot a...

Страница 18: ...s See Section 3 5 for details The wide selections of port modules are key to the flexibility and adaptability 2 2 1a Magnum 6K16V Managed Fiber Switch The Magnum 6K16V model of 6K16 Series family is p...

Страница 19: ...fy those requirement by the rich modular structure The Relay contacts for external ALARM is another additional feature which allows the Magnum 6K16V to monitor the internal power failure and controlle...

Страница 20: ...e mode combo of copper and fiber and a diversification option to select 10Mb fiber or 100Mb copper or 1000Mb copper Fiber are some of the primary benefits which allow the Magnum 6K16 to fulfill all th...

Страница 21: ...fiber ports are of the same speed 100Mb mode and connector type Models are available with Small Form Factor SFF are multi mode MT RJ or LC type connectors and single mode LC type connectors The 100Mb...

Страница 22: ...ed to match the device at the other end of the twisted pair cable See Section 4 3 for auto negotiation and MDIX details The auto crossover feature will automatically determine the other side of connec...

Страница 23: ...PoE modules option The LEDs on 6KP8 RJ45 PoE module are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use the PoE LED is ON when connected prop...

Страница 24: ...e module is as described for those port types above For detailed information about 10Mb mm ST fiber half of the module see Section 2 2 5 2 2 6 Four Port 10 Mb and 100Mb mm Fiber ST Modules The 4 port...

Страница 25: ...opper as well with new models appearing often The 1000Mb Gigabit fiber port modules on the Magnum 6K16 Series are normally set factory default to operate at AUTO mode for best fiber distance and perfo...

Страница 26: ...s which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be c...

Страница 27: ...at ftp ftp garrettcom com or FTP client program by ftp GarrettCom com using user m6kuser password m6kuser All MNS 6K software information including new releases and upgrades related to MNS 6K software...

Страница 28: ...l loss of power internally The other is software controllable and will signal user defined software events such as a security violation or an S Ring fault condition Vertical mounting for efficient con...

Страница 29: ...or integrating future proof fiber cabling into the LAN structure Example 1 Magnum 6K16 Series Switch for a Industrial application Equipped with lots of useful features hardened enclosure wide spread o...

Страница 30: ...reate a database of all the network subnets to easily manage the network Fig 2 4a The Industrial factory floor application with Magnum 6K16 Series Example 2 In another application a managed network is...

Страница 31: ...ovide a secure and stable network The 6K16 Series Managed Fiber with S ring and Link Loss Learn feature easily fulfilled the redundant requirement in a secured and faster reconfiguration time for cabl...

Страница 32: ...rt density in a rack mounting space The security features e g port security vlan Snmpv3 secure telnet etc also boost the Magnum 6K16 managed switches to provide a very effective ad reliable solution T...

Страница 33: ...s 3 1 Locating Magnum 6K16 Series Switches For vertical panel mounting and wall mounting see Section 3 4 For vertical DIN Rail mounting see Section 3 3 For DC power options see Appendix B For Dual Sou...

Страница 34: ...lor bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum PM to...

Страница 35: ...e used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto sensing for either 10 and 100Mb s The following procedure describes how to connect a 1...

Страница 36: ...2 6 Connecting Gigabit Media Using GBICs The Gigabit ports accept industry standard GBICs for user selection of the gigabit media type desired A selection of fiber and copper GBICs are available 3 3...

Страница 37: ...K16V from the DIN Rail mounting press the top of the two DIN Rail latches down simultaneously to release the 6K16V so that it can be dismounted by pulling the bottom out Once the bottom of the 6K16V i...

Страница 38: ...ypically a minimum of 1 inch Note that the back of the 6K16V unit is held out from the panel or wall behind it creating a rear space of about inch or 1cm This allows air circulation and cooling of the...

Страница 39: ...nder brackets for converting one K16 RMB or one K16 2TRAY to ETSI and or to 23 Telco rack The above mentioned rack mount kits is being designed for Magnum 6K16 only to provide the rack mount support t...

Страница 40: ...variations 3 5 Alarm Contacts for monitoring internal power and Software Traps The Alarm Contacts feature standard on Magnum 6K16 Series s provides two Form C Normally Closed NC contacts to which the...

Страница 41: ...ned for front viewing for the vertical mount 6K16 Series model The modules have the letter V in the model numbers but otherwise are the same In the Port Module materials below all modules are referred...

Страница 42: ...ssis Cover The Magnum 6K16 Series chassis consists of top bottom front and rear parts and assembled together with the help of 18 Philips head screws There are 6 screws located on the front panel of th...

Страница 43: ...rews shown in the picture below are used to secure a PM face plate in position but unscrew only four of the screws as shown in Fig below These screws are also used to secure the individual 6KPM cards...

Страница 44: ...PM card Each 6KPM card fits into the space provided on the main board Fig 3 6 2c Daughter Board top view of 4 copper 10 100 ports Fig 3 6 2d Daughter Board shown upside down with two male latch connec...

Страница 45: ...lot opening in the front panel This will maintain proper cooling air flow safety and operation as required by FCC CE and other regulations Step 6 Now screw down the daughter board with 6 440 screws so...

Страница 46: ...le there are six retaining screws for each 6KPM card These screws are used to secure a 6KPM card in position see Figure 3 6 3a Remove the three standoffs holding the Granddaughter board with the chass...

Страница 47: ...may be purchased as a separate item with the 6K16 Series unit They are not bundled with the unit Fig 3 7 Enlarged view of Magnum 6K16 Series Console Port area Note For a detailed description of Manage...

Страница 48: ...h are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destinat...

Страница 49: ...negotiation or not e g 10Mb Hub media converter or fixed mode at 10Mb or 100Mb Half Full Duplex managed switch No cross over cable is required while using the 6K8 s copper port to other devices Operat...

Страница 50: ...e other end is not an auto negotiating device the 6K16 Series s RJ 45 ports will try to detect its idle signal to determine 10 or 100 speed and will default to half duplex at that speed per the IEEE s...

Страница 51: ...ting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6K16 Series Switch implements a back pressure...

Страница 52: ...4 1300 62 5 125 50 125 20 23 5 31 31 9 0 5 5 3 0 2 0 15 8 12 2 5 5 4 0 6KPV MLC 100Mb FX Multi mode 2 0 4 1300 62 5 125 19 31 12 4 16 5 7 6KPV SLC 100Mb FX Single Mode 15 0 4 1310 9 125 15 28 11 22 G...

Страница 53: ...ship any of the PMs separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container if possible Ref...

Страница 54: ...plex when off The 10 100 LED indicates the speed if the LED is ON 100Mbps if it is OFF 10Mbps 5 2 1a 6KP6 RJ10ST 4 10 100Mbps RJ 45 and 2 10Mb multi mode FX ST twist lock Combo Module The 6KP6 RJ10ST...

Страница 55: ...6 Series switch They also provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports It supports distances according to the 10Base FL standard i e 2Km distance...

Страница 56: ...equipped with 4 10 100Mb RJ 45 ports along with 2 multi mode 100Mbps fiber optic transceivers all in one module This is similar to the 6K6 RJMST It has the same LEDs indicating port activity ACT Link...

Страница 57: ...provides a combination of copper and Fiber functions in one module to the 6K16 Series Switches supporting four Copper and two single mode Long Reach fiber network segments The 6KP6 RJSSC when installe...

Страница 58: ...IEEE standard 100Mbps distance limits i e typically 2km at full duplex and 412m at half duplex The functionality of this 100BASE FX multi mode 8 Port module is essentially the same as the ST and SC t...

Страница 59: ...tch it supports the standard distances as mentioned on 5 2 3 and the LEDs also act similarly 5 2 7 6KP8 MLC 8 ports 100Mbps multi mode LC connector Small Form Factor Magnum 6KP8 MLC is a eight port mu...

Страница 60: ...4 10 100 RJ 45 ports and 4 LC Small form factor multi mode fiber ports When installed in a Magnum 6K16 Series Switch it supports the standard distances as per mentioned on 5 2 8 and the LEDs also act...

Страница 61: ...wer on each port to power up the PD devices per the IEEE802 3af PoE standard The Power Pass through PoE modules are totally dependent upon the powerful 48VDC input power supply to support more RJ 45 1...

Страница 62: ...data traffic 5 2 11 6KP8 45 2MT 6 10 100Mbps RJ 45 and 2 100Mb multi mode FX MTRJ Small Form Factor The Magnum 6KP8 45 2MT eight port Module is a combo module with copper and fiber Small Form Factor M...

Страница 63: ...in two different flavor of G 2 100Mb fiber ports or G 4 10 100 RJ 45 ports as shown in the above figure The GBIC transceiver is fastened using snap in clips Insert the transceiver take care to insert...

Страница 64: ...J 45 ports or G 2 100Mb fiber ports as shown below in the above figure Each port has an Activity ACT LED indicating packets being received and a link LK LED indicating proper connectivity with the rem...

Страница 65: ...the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that...

Страница 66: ...ng personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrenc...

Страница 67: ...rn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettC...

Страница 68: ...for all Fiber ports Input Voltage 36 to 70 VDC 48VDC Input current 0 8Amps max for all RJ 45 ports Input current 1 2Amps max for all Fiber ports Input Voltage 115 to 150 VDC 125VDC Input current 0 3Am...

Страница 69: ...ons are particularly useful in the Industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 125VDC options are mainly used in power utilities such as electrical...

Страница 70: ...n building installation 4 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 5 Fastening torque of the lugs on the terminal block 9 inch pound max 6 Centralized DC Pow...

Страница 71: ...ding Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6K16 SERIES with 48VDC 24VDC and 125VDC Dual Source option The 6K16 Series Switch models with the internal 48VDC 24VDC and 125VDC Dual Sourc...

Страница 72: ...he 48VDC terminal block on the Magnum 6K16 Series Switch as shown in Fig C5 0 is located on the left front of the unit and is equipped with five 5 screw down lead posts The primary terminals are ident...

Страница 73: ...able to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block C6 0 ORDERING INFORMATION To order the optional Dual Source 48VDC power supply factory install...