11.7.6
Place unit in upright position at selected operating location.
CAUTION:
Adjust the width of the unit at the bottom of the panels to 30” (762mm) BEFORE making the holes
in the next step.
11.7.7
Secure the unit to the floor using 1/4” (6mm) mounting screws (not supplied). The mounting holes in
the plates may be used as a drill guide.
11.8
ELECTRICAL WIRING REQUIREMENTS
Magnascanner MT 5500 # 1167700
Comes with a standard American ground power cord. If the plug must be replaced or removed to hard
wire an AC junction box, use the following wiring list:
Green To
Ground
Black
To Line Hot
White
To Line Neutral
Magnascanner CS 5000 # 1167420 (International)
Comes with a European power cord. If the plug must be replaced or removed to hardwire to an AC
junction box, use the following wiring list:
Green/Yellow
To Ground
Brown
To Line Hot
Blue
To Line Neutral
MT 5500