4.1.3
FATAL ERRORS
The system continuously performs several of the tests described above. Errors 1,4 and 5 severely limit
or prohibit the operation of the Magnascanner and are considered Fatal Errors.
If a fatal error is encountered because of component failure, broken wire, etc., the audible alarm will
sound and the LED display will begin to flash. To remedy the situation, press the
OPERATE
touchpad,
which will initiate the self-diagnostic routine. Note the error(s) that will appear on the LED and follow
instructions stated above. If a solution is not obvious, it will be necessary to follow the repair procedure
described in Section 9.2.
4.1.4
NON-FATAL ERRORS
Errors 2, 3, and 6 may also occur. These failures do not limit the system’s detection capabilities and
the unit will continue to operate. Although the equipment is usable, it is important to identify and orrect
all problems as soon as possible in order to maintain full performance capabilities.
Another error indication is that of a warbling audio when a person is in the archway (or, for an extended
time if the IR Analysis is switched off). This sound indicates that a large metallic object, such as a
wheelchair, stroller, or very large hand-carried object, has “overloaded” the equipment to a degree that
it cannot function accurately. If this sound is heard, the operator should see that the problem object is
moved away, and the person being inspected should be required to pass through the archway again
after the green READY light appears.