5.
OPerATION
5.1
OPerATIONAL TesTING
5.1.1
OPerATIONAL TesT PIeCe
Actual forbidden objects should be used as targets for initial calibration. Once the detector
settings are established it is recommended that a Test Piece be selected which is similar in
size, shape and metallic composition to the smallest forbidden object. This Test Piece can
be used to generally verify operation on a regular basis without the necessity of having
actual weapons on-hand at the screening station.
Garrett offers an optional Operational Test Piece (OTP) that meets the specifications of the
U.S. Federal Aviation Administration (FAA) and is a representation of a small handgun.
Garrett also offers an optional Flat Test Piece (FTP) which represents a small knife (see
Section 8.8.) You may want to consider other test pieces if your screening operation requires
detection of objects other than guns and / or knives.
5.2
OPerATOr resPONsIBILITIes
The Operator must follow the Supervisor’s instructions regarding use of the PD 6500
i
and the
appropriate response to alarms.
The Operator’s ongoing responsibility is to ensure that the PD 6500
i
always operates accord-
ing to the information displayed on the LCD and to determine the cause of the alarms.
The Operator should ensure that the:
1. PD 6500
i
is always operating properly
2. Program and sensitivity settings are correct by pressing PROGRAM DISPLAY
3. LED bar graph shows minimal interference (two lights maximum)
4. Green READY light is on
5. Operational testing is performed according to the Supervisor’s instructions.
5.2.1
reADY LIGHT
The Green READY light must appear before a patron is permitted to enter the walk-through for
inspection.
If the READY light shuts off and remains off, the Operator should activate the self test report
by pressing the OPERATE touchpad; the results will appear on the LCD. During this time, no
one is permitted to enter the walk-through. Traffic may resume only when the READY light
reappears and remains on. If the READY light does not reappear or a failure message is
displayed on the LCD, the Operator should attempt to resolve the problem or consult the
Supervisor.
5.2.2
DIAGNOsTIC PrOBLeMs
As a general rule, the operator should follow the instructions regarding the appropriate
response to failures revealed by the self test. However, the operator may be able to remedy
the following failures: