6 MAINTENANCE
6.1
TO CLEAN THE CHARGING STATION
•
Use a damp cloth to clean the exterior of the
charging station.
CAUTION
Do not use running water or a hard brush to clean the
charging station, it can cause damage.
6.2
TO DO A VISUAL CHECK OF THE
CHARGING STATION
1. Make sure that the charging station is clean. Refer
to
6.1 To clean the charging station, page 79
2. Do a visual check of the charging station, Type 2
connector and the power cables. Do a check for
damages such as cracks or deformation.
WARNING
Do not use a damaged charging station. Turn off the
electric power and disable the charging station in the
GARO Connect app. Contact an authorized service
center.
6.3
TO DO A FACTORY RESET
CAUTION
The GARO support organization should approve a
factory reset. The factory reset should only be done as a
last resort in case of errors, such as lost contact to the
network or the GARO Connect app.
1. Stop charging and disconnect any EV.
2. Remove the front cover of the charging unit.
3. Do a long press, approximately 20 seconds, on the
test button (T) with the designation “T”. Use a pen or
similar. When pressing the button, the circuit
breaker will trip. The indication turns a blinking red.
4. After the light goes off, release the button and the
circuit breaker can be re closed. Refer to
a reset after a minor ground fault, page 80
5. Wait for the device to restart and the light to turn
green.
6.4
TO DO AN EARTH FAULT TEST
NOTE
Do an earth fault test one time each month.
1. Remove the front cover of the charging station.
2. Do a short press (max. 1 second) on the test button
(T) with the designation “T”. Use a pen or similar.
NOTE
When the test button is pressed, the indication light
becomes blinking red and the circuit breaker trips.
T
79