GARNI GARNI610 Precise Скачать руководство пользователя страница 5

 

 

Day name abbreviations 

 

 

Monday  Tuesday  Wednesday  Thursday  Friday  Saturday  Sunday 

CZ 

PO 

UT 

ST 

CT 

PA 

SO 

NE 

EN 

MO 

TU 

WE 

TH 

FR 

SA 

SU 

DE 

MO 

DI 

MI 

DO 

FR 

SA 

SO 

IT 

LU 

MA 

ME 

GI 

VE 

SA 

DO 

ES 

LU 

MA 

MI 

JU 

VI 

SA 

DO 

 
Wireless sensor 

                     
1)  Remove the battery compartment cover on the rear side of the wireless sensor. 
2)  Insert 2 pcs AAA batteries 

– observe the correct battery polarity 

3)  Press the TX button in the battery compartment 
4)  Close the battery compartment. Signal transmission is indicated by LED that flashes once every 
     60 seconds. 
 
When the signal is received successfully, the measured values are shown on the display on channel 1. 
 

Note: for the wireless sensor the lithium batteries are recommended due to their better resistance to frost.   
          Do not use rechargeable batteries. 

 
If the wireless sensor signal is lost, hold down the 

LIGHT / SNOOZE

 button on the main unit for 3 seconds. 

The main unit will re-commence searching for the wireless sensor signal.  
 

Using multiple wireless sensors 
 

If you want to use multiple wireless sensors or register a wireless sensor to another channel, then press the 

+ / CH

 button to select the channel and press the 

+ / CH

 button again for 3 seconds. A beep will sound and 

the signal strength indicator

 on the display of the main unit will flash. Now press the 

TX

 button in the 

battery compartment of the wireless sensor. Select a different channel for each wireless sensor. 
 

Once the connection of the main unit to the wireless sensor is established, the icon 

 will be displayed 

permanently. Place the main unit and the wireless sensor in the desired location within the range of the 
wireless sensor signal. 
     

 

The connection establishment process must be repeated after each battery replacement. 
 

Switching between wireless sensor channels 

 
If there are multiple wireless sensors paired with the main unit, press the 

- / CH

 button to display the 

measured temperature and relative humidity readings of each wireless sensor. For automatic switching of 
channels to which the wireless sensors are registered, press the 

SNOOZE / LIGHT 

button for 2 seconds, 

until the beep sounds. To terminate the automatic switching, press the 

SNOOZE / LIGHT 

button again for  

2 seconds, until the beep sounds. 
 

Placement 

 

Placement of the wireless sensor 

Place the wireless sensor away from direct sunlight not to compromise the measurement. Placement 
outdoors, at the northern wall is recommended. Obstacles such as walls, concrete, metal structures and 
large objects reduce the signal range. Position the wireless sensor vertically for optimum signal 
transmission.  
The signal range may be affected by obstacles (walls, trees) and other electrical devices (TVs, monitors, 
etc.). 
You may suspend the wireless sensor from the mounting hole or stand it. 
 

Содержание GARNI610 Precise

Страница 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Precise Precise ...

Страница 2: ...its of indoor and outdoor temperature weather forecast icons based on monitoring of changes in barometric pressure option to set a default weather forecast icon absolute relative barometric pressure display display of outdoor heat Index and dew point memory for maximum and minimum measured values of temperature and rel humidity memory for measured values of temperature rel humidity and barometric ...

Страница 3: ...imits of the outdoor temperature 5 Indoor temperature and relative humidity alarm upper and lower limits of the indoor temperature Rear side of the main unit 6 Mounting hole 7 Power adapter socket 8 Battery compartment cover 9 Acoustic alarm opening Wireless sensor GARNI 060H 10 TX button 11 Battery compartment cover 12 Battery compartment ...

Страница 4: ...Year will flash Use the MEM and CH buttons to set the current year and confirm with SET 7 Month will flash Use the MEM and CH buttons to set the current month and confirm with SET 8 Day will flash Use the MEM and CH buttons to set the current day and confirm with SET 9 The day name shortcut will flash Use the MEM and CH buttons to set the required language CZ Czech EN English DE German IT Italian ...

Страница 5: ...lash Now press the TX button in the battery compartment of the wireless sensor Select a different channel for each wireless sensor Once the connection of the main unit to the wireless sensor is established the icon will be displayed permanently Place the main unit and the wireless sensor in the desired location within the range of the wireless sensor signal The connection establishment process mus...

Страница 6: ...ioned to ensure good reception of the DCF 77 signal that is outdoors away from potential sources of interference Receiving and adjusting time can take up to 10 minutes MEMORY FOR MAX AND MIN MEASURED VALUES The main unit is equipped with memory for maximum and minimum measured values Press the MEM button repeatedly to display the maximum and minimum measured values of the indoor and outdoor temper...

Страница 7: ...ash Use the MEM and CH buttons to set the required temperature The temperature alarm is enabled or disabled by pressing the ALARM button The activation of the alarm is indicated on the display by the icon The upper limit alarm for the indoor temperature can be set from 9 C to 60 C the lower limit from 10 C to 59 C The upper limit alarm for the outdoor temperature can be set from 9 C to 70 C the lo...

Страница 8: ...reless sensor away from other electrical equipment the main unit keeps displaying the outdoor temperature and rel humidity even after the wireless sensor is disconnected the main unit displays the last measured data for 30 minutes after disconnection of the wireless sensor the temperature and rel humidity are different when the main unit and the wireless sensor are placed next to each other measur...

Страница 9: ...ature measurement range 10 C to 60 C Measurement accuracy 0 2 C 10 C to 50 C Resolution 0 1 C Humidity measurement range 1 to 99 Accuracy of measurement 2 20 to 80 4 1 to 20 80 to 99 Resolution 1 Outdoor HEAT INDEX from 26 C from 40 relative humidity Type of used sensors SENSIRION SHTC3 Dimensions 194 9 x 130 8 x 35 7 mm Wireless sensor GARNI 060H Power supply 2 pcs batteries type AAA 1 5 V micro ...