CHANGE TO / FROM DAYLIGHT SAVING TIME 

 

The change to / from daylight saving time is done automatically as long as the reception of the DCF-77 
signal is successful. If the daylight saving time is displayed, the display shows DST. 

 

DISPLAY BACKLIGHT 

 

Battery power 

Push button 

 to turn on the display backlight for 15 seconds. 

 

Powering with AC adaptor 

If the main unit is powered by the AC adaptor, the display backlight may be permanently on or turned off. 
Press the 

 button on the side of the main unit repeatedly to select the backlight brightness in 

4 brightness levels and turning off the display backlight. 

 

Empty battery icons 

 

Empty battery icon 

 on the main unit display: 

 
- in the indoor quantities area – the main unit batteries are empty 
- in the outdoor  quantities area – batteries of the wireless sensor are empty 

 

CHARGING DEVICES FROM USB 

 

Devices such as mobile phones, mp3 players, etc. can be charged via the USB port located on the rear of 
the main unit. Connect the device with a USB cable (not part of delivery). Follow the connected device 
manufacturer's instructions. The USB port can only supply a charging current of 1,000 mA. 
 

 

Note: 

the main unit must be powered by the AC adaptor while charging the device. 

 

TROUBLESHOOTING 

 

problem / situation                                                                  solution 

 
DCF-77 signal not received 

  relocate the main unit; start the manual signal search; 

    

  set the time and date manually 

 
instead of temperature and humidity readings 

  temperature readings are outside the measurable range 

the display shows: H.HH or LL.L 
 
the weather station is not working correctly 

  reset the factory settings of the main unit by removing 

   

  the batteries and disconnecting the AC adaptor for    

  30 seconds

 

 
intermittent connection between                                 reduce the distance between the main unit  
the main unit and the wireless sensor                         and the wireless sensor or relocate them 
 
between the main unit and the wireless sensor          relocate the main unit and the wireless sensor so that 
there are metal structures, frames etc.                       there are minimum obstacles between them which 

reduce the signal range 

 
the main unit or the wireless sensor are                     relocate the main unit and the wireless sensor further  
located close to other electrical devices                     away from other electrical devices to prevent signal 

interference 

 
the current time on the main unit  

 

 

  a wrong time zone was probably selected 

differs by one, two, three etc. hours 
 
 
the temperature reading from                                       place the sensor away from direct sunlight and 
the wireless sensor is too high                                      heating 

Содержание 545 line

Страница 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Line Line ...

Страница 2: ...wer limits of the outdoor temperature frost indication 5 icons of indoor thermal comfort weather forecast icons based on monitoring of changes in barometric pressure absolute barometric pressure display memory for maximum and minimum readings of temperature and rel humidity time and date controlled by DCF 77 radio signal with manual setting option 12 or 24 hour time display format alarm clock Moon...

Страница 3: ...gs switching between displaying seconds and date 15 Button saving wake up time switching between displaying set wake up time and date 16 Button increase set value switching between display of the temperature readings in degrees Centigrade C or Fahrenheit F manual start stop of reception of the DCF 77 signal 17 Button decrease set value display of readings from individual wireless sensors manual st...

Страница 4: ...remove them to avoid damage to the batteries and to the main unit Use only the delivered AC adaptor Powering with AC adaptor 1 Connect the AC adaptor plug into the socket on the rear side of the main unit 2 Connect the other side of the AC adaptor to a mains socket Battery power 1 Remove the battery compartment cover on the rear side of the main unit 2 Insert 2 pcs AA mini batteries observe the co...

Страница 5: ...Placement near TVs monitors computers etc may negatively affect the reception of the DCF 77 signal and the wireless sensor signal Wireless sensor Place the wireless sensor away from direct sunlight not to compromise the measurement Placement outdoors at the northern wall is recommended Obstacles such as walls concrete metal structures and large objects reduce the signal range Position the wireless...

Страница 6: ...ignal manually 3 Wait until the main unit automatically restarts the search 4 Set time and date manually Wireless sensor signal reception not successful 1 Check that the batteries in the wireless sensor are inserted correctly 2 Check that the wireless sensor is within the signal range 3 Press and hold button to start signal search manually Manual setting of time and date 1 Press and hold button un...

Страница 7: ...PM 3 Current day of the week 4 Displaying the set wake up time pressing button or switches between displaying the day and month seconds and the set wake up time 5 Alarm clock on icon Indoor outdoor temperature and relative humidity Remote sensor the readings of the outdoor quantities from the wireless sensor sensors Indoor sensor the indoor readings measured by the main unit 1 Temperature unit C o...

Страница 8: ...Barometric pressure decreased in the last 3 hours E g the weather forecast indicates rain the barometric pressure drops abruptly and quickly therefore the probability of heavy rain is higher Arrows of temperature relative humidity trends The main unit displays the trend icons of the measured quantities based on the temperature and relative humidity readings Temperature relative humidity increases ...

Страница 9: ...perature pleasant Humidity pleasant Temperature higher or lower temperature than pleasant Humidity higher or lower humidity than pleasant Temperature unpleasant cold or hot Humidity unpleasant dry or wet Temperature too cold or hot Humidity too dry or wet CHANGING THE TEMPERATURE UNITS To change the temperature units to Centigrade C or Fahrenheit F press button DISPLAYING THE MAX AND MIN READINGS ...

Страница 10: ...ton icon disappears Frost indication The frost indication function and the set point alarm are closely linked when the high and low temperature alarm is active the frost indication function is automatically activated As soon as the outdoor temperature is between 1 C and 3 C the icon is displayed Note Even if the icon is not displayed remember that there is a risk of icing at temperatures around ze...

Страница 11: ...ote the main unit must be powered by the AC adaptor while charging the device TROUBLESHOOTING problem situation solution DCF 77 signal not received relocate the main unit start the manual signal search set the time and date manually instead of temperature and humidity readings temperature readings are outside the measurable range the display shows H HH or LL L the weather station is not working co...

Страница 12: ...ptor 100 240 V 50 60Hz 0 3 A 5V 1 2 A 2 pcs of 1 5 V AA batteries mini Temperature measurement range 9 9 C to 50 C Accuracy of measurement 1 C Resolution 0 1 C Rel humidity measurement range 20 to 95 Accuracy of measurement 5 Resolution 1 Absolute barometric pressure measurement range 600 hPa mb to 1100 hPa mb Dimensions 205 x 130 x 30 mm Wireless sensor GARNI 030H Power supply 2 pcs of 1 5 V AA b...

Отзывы: