background image

 

 

Activating and deactivating the alarm 

 
To activate or deactivate the high and low outside temperature alarm, briefly press the 

ALERT

 button.

 

 

When the alarm is activated, the main unit display shows the icon 

 

 

As soon as the set temperature of the upper or lower outdoor temperature limit has been reached, a beep 

sounds and icon 

 or 

 and the temperature value will flash. The beep will repeat every minute.  

You can disable the alarm by pressing the 

ALERT 

button. 

 
 

ALARM CLOCK 

 

Setting of alarm time 

 
The weather station has the possibility to set the alarm for every day (MO-SU) or Monday to Friday (MO-
FR). In the basic display mode, press the 

ALARM

 button at the rear of the main unit and hold for 3 

seconds. The alarm time will be displayed at the time spot and the hour will flash. Use the 

/MEM 

or 

/CF

 buttons to set the required wake-up hour and press 

ALARM 

briefly. Minutes will flash. Use the 

/MEM 

or 

/CF

 button to set the required wake-up minute. Next press of the 

ALARM

 button will flash 

MO-SU or MO-FR.  Use the 

/MEM 

or 

/CF

 buttons to select MO-SU, (wake-up every day), or MO-FR 

(wake-up Monday to Friday). Press 

ALERT

 to confirm and save the setting.

 

The wake-up time can be shown in the basic display by briefly pressing the 

ALARM

 button.  The current 

time will reappear automatically after 20 s or after pressing of the 

SET 

button briefly. 

 
Activating and deactivating the alarm clock 

 

Press the 

ALARM

 button briefly in the basic display mode to show the wake-up time.

  Press again to 

activate the alarm, the icon 

 will show together with the selected alarm mode MO-SU or MO-FR; press 

again to deactivate the alarm. The icon 

 and the selected alarm mode MO-SU / MO-FR will not be 

displayed. 

 

Turning off alarm signal, Snooze function 

 

As soon as the alarm signal is activated at the preset time, icon 

starts flashing. Press the 

 

button to move the alarm time by 5 minutes (Snooze).  The alarm signal will be terminated and reactivated 

in 5 minutes. The icon 

 and 

Z

Z

 will flash on the display. 

 This function can be terminated at any time by pressing 

any button except 

. If you do not want the Snooze function, press the any button except 

to disable the alarm signal. Icon 

 

stops flashing and the next alarm will be activated in 24 

hours.  
 
If no button is pressed, the alarm signal will be turned off automatically after 2 minutes. 

 

WEATHER FORECAST 

 
The forecast is based on the change in barometric pressure, generally speaking when the barometric 
pressure rises, the weather improves and vice versa. The weather forecast is valid for the next 12 to 24 
hours within  
30 to 50 km with the probability of 70 to 75% 
 
 
 
 
 
 

 

Содержание 525

Страница 1: ...1 INSTRUCTION MANUAL FOR WEATHER STATION MODEL GARNI 525 GARNI 525 ...

Страница 2: ...pper and lower limits of the outdoor temperature time and date controlled by DCF 77 radio signal with manual setting option 12 or 24 hour time display format date alarm clock Moon phase 5 minute snooze function Snooze permanent display backlight option when on mains power 3 backlight brightness levels the main unit and the wireless sensor can be suspended or stand the wireless sensor is included i...

Страница 3: ... 24 Wireless sensor low battery icon 25 Trend arrow 17 Date 18 Moon phase 19 Channel number 26 Indoor relative humidity 27 Main unit low battery icon 28 Indoor temperature 20 Icon of activated alarm clock Snooze function Zz 21 Time 29 Wireless sensor signal reception icon 30 Indoor relative humidity 22 DCF 77 signal reception icon Wireless sensor GARNI 045H ...

Страница 4: ...all not be suspended but stand Wireless sensor 1 Remove the battery compartment cover on the rear side of the wireless sensor 2 Set the required channel using the CH switch 3 Insert 2 pcs AAA batteries micro observe the correct battery polarity 4 After the batteries are inserted a signal is sent to the main unit The signal can also be sent manually using the TEST button in the battery compartment ...

Страница 5: ... of the main unit The main unit can be also placed on a flat surface using the two stands that are stored in the battery compartment and can be screwed into the two holes on the back of the main unit SETUP OF THE WEATHER STATION To enter the settings mode press and hold the SET button in the main screen mode for 3 seconds For settings use the MEM and CF buttons To save press the SET button once 1 ...

Страница 6: ...date time are not adjusted then also at 2 03 3 03 4 03 and 5 03 Reception of the DCF 77 signal can be started manually by pressing and holding the CF button for 3 seconds Receiving and adjusting time can take up to 10 minutes The DST label next to the time indicates the daylight savings time MEMORY FOR MAX AND MIN MEASURED VALUES The main unit is equipped with memory for maximum and minimum measur...

Страница 7: ...ay by briefly pressing the ALARM button The current time will reappear automatically after 20 s or after pressing of the SET button briefly Activating and deactivating the alarm clock Press the ALARM button briefly in the basic display mode to show the wake up time Press again to activate the alarm the icon will show together with the selected alarm mode MO SU or MO FR press again to deactivate th...

Страница 8: ... s TROUBLESHOOTING problem possible cause solution time is not adjusted by the DCF 77 signal time is adjusted incorrectly incorrectly set timezone DCF 77 signal reception not on DCF 77 signal interference setting the correct timezone turning the DCF 77 signal reception on place the main unit away from other electrical equipment the outdoor temperature and rel humidity are not displayed the connect...

Страница 9: ...Main unit Power supply power adaptor 230 V 50 Hz 90 mA 4 5 V 200 mA 3 pcs batteries type AAA 1 5 V micro Temperature measurement range 10 C to 50 C Accuracy of measurement 1 C Resolution 0 1 C Humidity measurement range 20 to 99 Accuracy of measurement 5 Resolution 1 Bar pressure measurement range 800 to 1100 hPa Dimensions 143 x 140 x 24 mm without stand Wireless sensor GARNI 045H Power supply 2 ...

Отзывы: