IMPORTANT SAFETY NOTES

No operator-serviceable parts inside 

unit. Maintenance to be done only by 

trained personnel.
High Voltage exists inside unit even 

when equipment is not under power. 

All trouble shooting and wiring checks 

must be performed by a qualified 

electrician or authorized plant 

personnel. 
Disconnect main power and unplug 

unit from the wall before installing 

or removing device or servicing 

equipment.

PACE MAKER USERS

Due to stray magnetic fields, consult 

your physician before operating.

A non-shielded power cord may 

be used to connect AC power to 

the system. Use only power cords 

approved by Garner Products.
For continued protection against risk of 

fire, replace fuses with fuses of same 

types and ratings only.
Airflow is important. Do not cover 

chassis ventilation slots or block 

enclosure openings.
Check input voltage selection; if not 

compatible with wall voltage, have 

technician qualified by Garner Products 

modify wiring inside this system before 

connecting system plug to wall voltage.
Unplug power cord from the wall to 

disconnect power to the system. 

CONTROLS AND INDICATORS

POWER Button (RED) The power button switches the power on and off.
Media Drawer The media drawer holds the media to be degaussed and activates and deactivates 

the degaussing cycle when in the closed and open positions.

LCD display The LCD display gives status, automatic count, total count, software version, field 

strength, user instructions and fault messages.

LCD DISPLAY

DEGAUSSING INSTRUCTIONS

The following information appears on 

the LCD Display from power-up through 

one automatic degaussing cycle:

Automatic Degaussing

Step 1: Press POWER button ON

Displays Manufacturer.

Displays Degausser Model.

Displays current firmware version.

Displays total erasing cycles. Number on left indicates 

number of times the counter reached 50,000.

Ready for media to be placed in the Media Drawer. 

Counter for erase cycles from power up.

Step 2: Open media drawer, insert media, 

and close drawer

Close the drawer. The erase cycle starts automatically.

Displays capacitor charging status.

Displays erasure status.

Visual indicator of erasing field strength and erasure 

results. 

Step 3: Open drawer and remove media

Opening the drawer completes the cycle and Session 

# will appear.

Ready for next cycle. Closing the drawer starts the 

next cycle.

INITIATION

I

ntroduction

The Garner TS-1XT series are continuous duty capacitive 

discharge degaussers. The units are designed to erase 

hard drives and tape cartridges that fit inside the drawer. 

Inspection

Inspect the degausser for shipping damage as soon as 

it is unpacked. If the degausser or any accessories are 

damaged or fail to operate correctly, notify carrier and 

contact your dealer immediately.

INSTALLATION

Power Plug

Plug the IEC connector attached to the power cord supplied 

into the receptacle on the back of the unit.

Location

The degausser must be placed on a flat, hard surface. 

Keep at least a 15 cm (6 inch) distance from any object 

that may interfere with the coo ling fan exhaust located on 

the backside of the degausser. 

Cooling

Forced air-cooling is used to maintain safe ope rating 

temperatures within the degausser. To ensure proper 

cooling, do not block the air-intake and maintain at least a 

15 cm (6 in.) distance from the back of the degausser to 

any obstacle.

US

LCD DISPLAY ERROR CODES

Charge Error
The LCD displays “Charge Error”. This error indicates that 

the degausser failed to charge to the determined power 

level necessary to successfully erase the media in the 

degaussing chamber.

Action:

 Turn off the degausser for one minute and restart. 

(Turning off the power to the degausser will clear the error.) 

If error persists, call customer support.
Gauss Error
The LCD displays “Gauss Error”. This error indicates the 

erasing field may not have been adequate to effectively 

erase the media in the degaussing chamber. 

Action:

 Turn off the degausser for approximately one 

minute. Turning off the power to the degausser will clear 

the error. Turn the degausser back on. To initiate the 

degauss cycle with media already in the media drawer, 

open the media drawer and close it. The media in the 

degaussing chamber will be erased if the field is sufficient 

otherwise the “Gauss Error” will persist on the LCD screen. 

If error persists, call customer support.
Media Drawer Open Error
The LCD displays “Drawer Open”. This error indicates that 

the Media Drawer is not completely closed. The degausser 

continuously checks to see if the Media Drawer is closed. 

If the drawer is not closed, the “Drawer Open” will persist 

on the LCD. Once the drawer is closed, the degausser will 

automatically continue the erase function.

Action:

 Check to see that drawer is seated in detent.