190-01553-00
GTR 200 Installation Manual
Rev. B
Page A-9
A.5 Shield Termination-Method B.2 (Daisy Chain-Quick Term)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal
(Figure A-6). All other restrictions and instructions for the shield termination technique set forth for
Method B.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure A-6 Method B.2 (Daisy Chain-Quick Term) for Shield Termination
Table A-3 Shielded Cable Preparations – (Quick Term)
Backshell Size
Number of Pins
Std/HD
Quick Term Min
(inches)
Quick Term Max
(inches)
Quick Term
Float (inches)
1
9/15
1.25
2.25
1.75
2
15/26
1.5
2.5
2.0
3
25/44
1.5
2.5
2.0
4
37/62
1.5
2.5
2.0
5
50/78
1.5
2.5
2.0