GRS 77/GMU 44 Installation Manual
Page 1-3
190-00303-10
Revision
L
1.4.2 Physical Characteristics
Specification
Characteristic
GRS 77 Weight
(Unit Only) 2.80 lbs. (1.27 kg)
(Installed with rack and connectors) 3.50 lbs. (1.59 kg)
GMU 44 Weight
(Unit Only) 0.35 lbs. (0.16 kg)
(Installed with rack and connectors) 0.50 lbs. (0.23 kg)
Physical Dimensions:
GRS 77
Height: 3.25 inches (82.6 mm)
Width: 3.75 inches (95.3 mm)
Length: 8.50 inches (215.9 mm)
Rack length: 8.25 inches (209.5 mm)
Rack width: 3.25 inches (82.6 mm)
Physical Dimensions:
GMU 44
Height: 2.10 inches (53.3 mm) (Excluding Pigtail)
3.35 inches (85.1 mm) Dia including flange
1.4.3 General Specifications
The table below contains general environmental specifications. For detailed specifications, see the
applicable Environmental Qualification Forms.
Specification Characteristic
Regulatory Compliance
RTCA/DO-160D Environmental Conditions and EUROCAE/ED-14D
Hardware Compliance
GRS 77: RTCA/DO-254 Level A
Unit Software
GRS 77 (software versions 3.00 and later): RTCA/DO-178B Level A
GRS 77 (software versions prior to 3.00): RTCA/DO-178B Level B
GMU 44 (all software versions): RTCA/DO-178B Level B
Operating Temperature
Range
-55
°
C to +70
°
C
Altitude 55,000
Feet
1.4.4 Power Requirements
Specification Characteristic
Power Requirements
Including GMU 44
Supply Voltage: 14/28 Vdc. See the Environmental
Qualification Form* for details on surge ratings and
minimum/maximum operating voltages. (Operating
Current: 0.3 A normal operation, 27.5 Vdc,
≤
8 watts)
*NOTE: As stated in Note 3 of the GRS 77 EQF (005-00165-31) the power inputs of the GRS 77 are
rated to sustain A4 (waveform 4 level 4 and waveform 3 level 4) if both are connected to a power input.
In the case of a single power source, where typically only one of the power pins would be used, both pins
should be connected to this wire to get A4. The splice must be in the backshell of the GRS 77. Generally
every installation should do this unless it is known that A3 on the power pins will suffice. Installations
that input 2 different power sources to the two power input pins will need to be examined on a case by
case basis.
Содержание GRS 77
Страница 1: ...190 00303 10 March 2010 Revision L GRS 77 GMU 44 Installation Manual ...
Страница 10: ...Page viii GRS 77 GMU 44 Installation Manual Revision L 190 00303 10 This page intentionally left blank ...
Страница 18: ...Page 1 8 GRS 77 GMU 44 Installation Manual Revision L 190 00303 10 This page intentionally left blank ...
Страница 26: ...Page 2 8 GRS 77 GMU 44 Installation Manual Revision L 190 00303 10 This page intentionally left blank ...
Страница 32: ...Page 3 6 GRS 77 GMU 44 Installation Manual Revision L 190 00303 10 This page intentionally left blank ...