Appendix A. CR23X/CR10X Programs
Additional input locations used in the example program are:
18) Orig_TM, Copy of original time
19) Int1, Place holder for math
20) Hours, formatted hours
21) Minutes, formatted minutes
22) Seconds, formatted seconds
23) remainder, place holder for math
Before writing any datalogger code, it’s best to enter all the input locations
needed. In Edlog, open the input location editor (F5) and enter names for the
input locations listed above. When an input location is needed, use the input
location pick list (F6).
;{CR23X}
;
*Table 1 Program
01: 60
Execution
Interval
(seconds)
; Instruction to eliminate warning about unused subroutine, not needed
1: If Flag/Port (P91)
1: 11
Do if Flag 1 is High
2: 98
Call
Subroutine
98
*Table 2 Program
02: 0.0000 Execution
Interval
(seconds)
*Table 3 Subroutines
1: Beginning of Subroutine (P85)
1: 98
Subroutine
98
;--- read serial data non-buffered
2: Port Serial I/O (P15)
1: 1
Reps
2: 61 --
RS-232 ASCII (decimal delimiter), 1200 Baud
3: 1
Delay (0.01 sec units) before TX
4: 5
No
RTS/DTR,
C5
TXD/RXD
5: 1
Start Loc for TX [ Raw_Time ]
6: 0
Number of Locs to TX
7: 42
Termination Character for RX
8: 100
RX Buffer Size or Max Chars to RX if Par 2 indexed (--)
9: 80
Time Out for CTS (TX) and/or RX (0.01 sec units)
10: 1
Start Loc for RX [ Raw_Time ]
11: 1.0
Mult
for
RX
12: 0.0
Offset
for
RX
;--- filter for $GPGGA
3: Extended Parameters (P63)
1: 36
Option
;$
2: 71
Option
;G
3: 80
Option
;P
4: 71
Option
;G
5: 71
Option
;G
6: 65
Option
;A
7: 0
Option
8: 0
Option