5.2.10.2.2 King Serial DME Tuning
When SERIAL DME – DATA or SERIAL DME – CLOCK is asserted high and driving a 360
load, the
driver output voltage is not less than 8 V, and when asserted low is not greater than 10 mV.
SERIAL DME – RNAV/CH REQ, SER DME – RNAV MODE, and DME COMMON are considered
active if either the voltage to ground is less than 1.9 V or the resistance to ground is less than 375
. These
inputs are considered inactive if the voltage to ground is 11-33 VDC.
DME COMMON must be pulled low to indicate to the GTR/GNC that it is the device channeling the
DME.
Pins 18, 19, 20, and 41 are configured for King Serial DME tuning.
Pin Name
Connector
Pin
I/O
SERIAL DME - DATA
P2002
19
I/O
SERIAL DME - CLOCK
P2002
18
I/O
SERIAL DME - RNAV/CH REQ
P2002
20
In
SERIAL DME - RNAV MODE
P2002
21
In
DME COMMON
P2002
41
In
SERIAL DME - DME REQUEST
P2002
44
I/O